Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3044814 Phoenix Contact Terminal Blocks

Phoenix Contact 3044814 Double-level terminal block, connection method: Screw connection, cross section: 0.14 mm² - 6 mm², AWG: 26 - 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3044814

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 10

Nov 2, 2024

Double-level terminal block, connection method: Screw connection, cross section: 0.14 mm² - 6 mm², AWG: 26 - 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3044814 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27141100
  • ETIM 3.0
    EC000901
  • ETIM 7.0
    EC000897
  • UNSPSC 20.0
    39121410
  • Test duration per axis
    5 h
  • Insulating material group
    I
  • Nominal voltage UN
    800 V
  • Bending test rotation speed
    10 rpm
  • Tight fit on carrier
    NS 35
  • Setpoint
    1 N
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of shocks per direction
    3
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Conductor cross section solid min.
    0.14 mm²
  • Conductor cross section AWG min.
    26
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • 2 conductors with same cross section, stranded max.
    1.5 mm²
  • Internal cylindrical gage
    A4
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Area of application
    Railway industry
  • Overvoltage category
    III
  • Power frequency withstand voltage setpoint
    2 kV
  • Result of temperature-rise test
    Test passed
  • Result of tight fit on support
    Test passed
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Acceleration
    30g
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Height NS 35/7,5
    65 mm
  • Height NS 35/15
    72.5 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • 2 conductors with same cross section, solid min.
    0.14 mm²
  • 2 conductors with same cross section, stranded min.
    0.14 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    2.5 mm²
  • Stripping length
    9 mm
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.14 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.14 mm²
  • Rated surge voltage
    8 kV
  • Maximum load current
    36 A (with 6 mm² conductor cross section)
  • Checking the mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of surge voltage test
    Test passed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Shock test result
    Test passed
  • Relative insulation material temperature index (Elec.; UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section solid max.
    6 mm²
  • Tightening torque, min
    0.6 Nm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 6.0
    EC000897
  • Degree of pollution
    3
  • Nominal current IN
    30 A
  • Bending test turns
    135
  • Short circuit stability result
    Test passed
  • Shock form
    Half-sine
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Width
    6.2 mm
  • Connection method
    Screw connection
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.14 mm²
  • 2 conductors with same cross section, solid max.
    1.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Tightening torque max
    0.8 Nm
  • ECLASS 10.0.1
    27141120
  • ECLASS 7.0
    27141120
  • UNSPSC 12.01
    39121410
  • UNSPSC 7.0901
    39121410
  • Conductor cross section short circuit testing
    4 mm²
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Shock duration
    18 ms
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Length
    69.9 mm
  • Conductor cross section AWG max.
    10
  • Conductor cross section flexible max.
    6 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.1
    27141100
  • ETIM 2.0
    EC000901
  • UNSPSC 6.01
    30211811
  • UNSPSC 21.0
    39121410
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 11.0
    27141120
  • ECLASS 4.0
    27141100
  • ETIM 4.0
    EC000897
  • ECLASS 9.0
    27141120
  • UNSPSC 13.2
    39121410
  • Number of levels
    2
  • Back of the hand protection
    guaranteed
  • Result of thermal test
    Test passed
  • Flammability rating according to UL 94
    V0
  • Color
    gray
  • Connection in acc. with standard
    CSA
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Screw thread
    M3
  • UNSPSC 11
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • UNSPSC 18.0
    39121410
  • Nominal cross section
    4 mm²
  • Maximum power dissipation for nominal condition
    1.02 W (the value is multiplied when connecting multiple levels)
  • Open side panel
    Yes
  • Insulating material
    PA
  • Finger protection
    guaranteed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • UNSPSC 19.0
    39121410
  • Number of connections
    4
  • Short-time current
    0.48 kA

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$2.81

Stock:

10

Select Qty:

$2.81

$2.81 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo