Feed-through terminal block, nom. voltage: 1000 V, nominal current: 32 A, connection method: Screw connection, number of connections: 2, cross section: 0.14 mm² - 6 mm², AWG: 26 - 10, width: 6.2 mm, height: 46.9 mm, color: blue, mounting type: NS 35/7,5,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3044115 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 6.0 27141100
- UNSPSC 12.01 39121410
- UNSPSC 19.0 39121410
- Connection in acc. with standard CSA
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- ECLASS 11.0 27141120
- ETIM 4.0 EC000897
- ETIM 6.0 EC000897
- UNSPSC 13.2 39121410
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- UNSPSC 20.0 39121410
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- ECLASS 5.1 27141100
- UNSPSC 11 39121410
- UNSPSC 18.0 39121410
- ECLASS 9.0 27141120
- ETIM 3.0 EC000897
- UNSPSC 21.0 39121410
- Potentials 1
- Overvoltage category III
- Nominal voltage UN 1000 V
- Finger protection guaranteed
- Result of tight fit on support Test passed
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Short-time current 0.72 kA
- Result of thermal test Test passed
- Test directions X-, Y- and Z-axis (pos. and neg.)
- ASD level 1.857 (m/s2)2/Hz
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height NS 35/15 55 mm
- Screw thread M3
- Insulating material PA
- Result of voltage-drop test Test passed
- Setpoint 1 N
- Conductor cross section short circuit testing 6 mm²
- Number of connections 2
- Area of application Railway industry
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Bending test turns 135
- Tight fit on carrier NS 35
- Short circuit stability result Test passed
- Test spectrum Service life test category 1, class B, body mounted
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- End cover width 2.2 mm
- Tightening torque max 0.8 Nm
- Conductor cross section AWG max. 10
- Max. AWG conductor cross section, flexible 10
- 2 conductors with same cross section, solid min. 0.14 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Shock form Half-sine
- Number of shocks per direction 3
- Surface flammability NFPA 130 (ASTM E 162) passed
- Number of levels 1
- Color blue
- Rated surge voltage 8 kV
- Degree of pollution 3
- Open side panel Yes
- Result of temperature-rise test Test passed
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Acceleration 5g
- Static insulating material application in cold -60 °C
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Height 46.9 mm
- Stripping length 9 mm
- Conductor cross section solid max. 6 mm²
- Conductor cross section AWG min. 26
- Min. AWG conductor cross section, flexible 26
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
- 2 conductors with same cross section, stranded min. 0.14 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- Result of surge voltage test Test passed
- Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 4 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.14 mm²
- Internal cylindrical gage A4
- Tensile test result Test passed
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Oscillation, broadband noise test result Test passed
- Shock test result Test passed
- Shock duration 30 ms
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Width 6.2 mm
- Height NS 35/7,5 47.5 mm
- Tightening torque, min 0.6 Nm
- Note Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
- ECLASS 10.0.1 27141120
- ECLASS 4.0 27141100
- ECLASS 5.0 27141100
- ETIM 2.0 EC000897
- UNSPSC 6.01 30211811
- Power frequency withstand voltage setpoint 2.2 kV
- Result of flexion and pull-out test Test passed
- Insulating material group I
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Maximum load current 41 A (with 6 mm² conductor cross section)
- Nominal current IN 32 A (with 4 mm² conductor cross section)
- Back of the hand protection guaranteed
- Nominal cross section 4 mm²
- Flammability rating according to UL 94 V0
- Maximum power dissipation for nominal condition 1.02 W
- Result of power-frequency withstand voltage test Test passed
- Bending test rotation speed 10 rpm
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
- ECLASS 7.0 27141120
- 2 conductors with same cross section, solid max. 1.5 mm²
- 2 conductors with same cross section, stranded max. 1.5 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Length 47.7 mm
- Conductor cross section flexible min. 0.14 mm²
- ETIM 7.0 EC000897
- UNSPSC 7.0901 39121410
- Test duration per axis 5 h
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Conductor cross section solid min. 0.14 mm²
- Conductor cross section flexible max. 6 mm²
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.1 27141100
- Connection method Screw connection
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$1.50
Stock:
15,692
Select Qty:
$1.50
$1.50 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨