About the product: Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, order configuration.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1052472 Phoenix Contact price in the box on the right side or send a quick quote.
1052472 Product Details
- Height 112.5 mm
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Rated insulation voltage 300 Vrms
- Max. permissible overall conductor resistance 50 Ω (Per cable)
- Load/output load current output ≤ 600 Ω
- Nominal supply voltage 24 V DC
- Stripping length 7 mm
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Temperature coefficient, typical 0.01 %/K
- Housing material PA 6.6-FR
- Standards/regulations GB 3836.1
- DNV GL-Temperature B
- Additional text and EN 61326
- Vibration A
- ECLASS 5.0 27210120
- ECLASS 6.0 27210120
- ETIM 4.0 EC001446
- UNSPSC 7.0901 39121008
- UNSPSC 20.0 41112105
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Temperature measuring range -200 °C ... 850 °C (Range depending on the sensor type)
- Configurable/programmable Yes
- Power dissipation ≤ 0.76 W
- Conductor cross section AWG 24 ... 14
- Transmission error, typical 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
- Alignment span ± 5 %
- Electromagnetic compatibility Conformance with EMC directive
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Degree of pollution 2
- Noise emission EN 61000-6-4
- DNV GL-Vibration A
- Humidity B
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27210120
- ETIM 3.0 EC001446
- UNSPSC 6.01 30211506
- UNSPSC 18.0 41112105
- UNSPSC 19.0 41112105
- Depth 114.5 mm
- Altitude ≤ 5000 m
- Sensor input current 10 µA ... 210 µA (Up to 2x 210 µA with 3-conductor technology)
- Current output signal 0 mA ... 20 mA
- Power consumption ≤ 1 W
- Torque 0.5 Nm ... 0.6 Nm
- Alignment zero ± 5 %
- Designation Safety Integrity Level (SIL, IEC 61508)
- Conformance CE-compliant, additionally EN 61326
- DNV GL-EMC B
- Temperature B
- EMC B
- ECLASS 11.0 27210129
- ECLASS 9.0 27210129
- ETIM 7.0 EC002919
- UNSPSC 13.2 41112105
- Width 12.5 mm
- Ambient temperature (operation) 49 °C
- Degree of protection IP20
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors: 2, 3, 4-wire
- Input signal range 0 Ω ... 50 kΩ
- Signal output Current output
- Max. current output signal ≥ 21 mA
- Output ripple (current) < 15 µAPP
- Connection method Screw connection
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- No. of channels 1
- Status display Green LED (supply voltage, PWR)
- Color gray
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- IECEx Ex ec ic IIC T4 Gc
- DNV GL-Humidity B
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.0 27210120
- ECLASS 7.0 27210120
- ETIM 2.0 EC001446
- UNSPSC 11 39121008
- UNSPSC 21.0 41112105
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Measuring range span ≥ 50 K
- Behavior in the event of a sensor error As per NE 43 or can be freely defined
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Screw thread M3
- Step response (0–99%) typ. 1 s
- Interference emission EN 61000-6-4
- Overvoltage category II
- Typical deviation from the measuring range final value 1 %
- ATEX II 3 G Ex ec ic IIC T4 Gc
- Identification 2
- Certificate DNV GL TAA00000AG
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 10.0.1 27210129
- ECLASS 5.1 27210120
- ETIM 6.0 EC002919
- UNSPSC 12.01 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
1052472
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨