1052463 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:1052463
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, SIL, screw connection, order configuration.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1052463 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- UNSPSC 18.0 41112105
- Ambient temperature (operation) 49 °C
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Input signal range 0 Ω ... 50 kΩ
- Signal output Current output
- Behavior in the event of a sensor error As per NE 43 or can be freely defined
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Configurable/programmable Yes
- Width 12.5 mm
- Nominal supply voltage 24 V DC
- Conductor cross section AWG 24 ... 14
- Transmission error, typical 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
- Status display Green LED (supply voltage, PWR)
- Color gray
- Overvoltage category II
- Group IIC/IIB/IIA
- ATEX I (M1) [Ex ia Ma] I
- Degree of protection IP20
- Height 112.5 mm
- Altitude ≤ 5000 m
- Measuring range span ≥ 50 K
- Depth 114.5 mm
- Sensor types (RTD) that can be used Sensors (2-, 3-, 4-conductor)
- Current output signal 0 mA ... 20 mA
- Power dissipation ≤ 0.76 W
- Max. permissible overall conductor resistance 50 Ω (Per cable)
- Output ripple (current) < 15 µAPP
- Power consumption ≤ 1 W
- Screw thread M3
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Temperature measuring range -200 °C ... 850 °C (Range depending on the sensor type)
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Rated insulation voltage 300 Vrms
- Torque 0.5 Nm ... 0.6 Nm
- Alignment zero ± 5 %
- Temperature coefficient, typical 0.01 %/K
- Housing material PA 6.6-FR
- Max. internal capacitance Ci 47 µF
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- Input voltage Ui 7 V
- Safety-related maximum voltage Um 253 V AC (125 V DC, Zone 2: 3.1, 3.2 = 30 V DC)
- Conformance CE-compliant, additionally EN 61326
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- DNV GL-Vibration A
- Temperature B
- EMC B
- ECLASS 5.1 27210120
- ECLASS 5.0 27210120
- ETIM 2.0 EC001446
- ETIM 3.0 EC001446
- UNSPSC 13.2 41112105
- Sensor input current 10 µA ... 210 µA (Up to 2x 210 µA with 3-conductor technology)
- Load/output load current output ≤ 600 Ω
- Stripping length 7 mm
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- No. of channels 1
- Electromagnetic compatibility Conformance with EMC directive
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Degree of pollution 2
- Max. output current Io 400 mA
- Max. external inductivity Lo 20 µH
- Input current Ii 100 mA
- Standards/regulations GB 3626.20
- IECEx [Ex ia Ma] I
- DNV GL-EMC B
- Certificate RU C-DE.AB72.B.00093/19
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 4.1 27210120
- ECLASS 6.0 27210120
- Connection method Screw connection
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Interference emission EN 61000-6-4
- Designation EAC Ex
- Max. output voltage Uo 3.5 V
- Input power Pi 550 mW
- Noise emission EN 61000-6-4
- DNV GL-Temperature B
- Additional text and EN 61326
- Vibration A
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 10.0.1 27210129
- ECLASS 11.0 27210129
- ECLASS 9.0 27210129
- ETIM 7.0 EC002919
- UNSPSC 11 39121008
- UNSPSC 19.0 41112105
- Step response (0–99%) typ. 1 s
- Alignment span ± 5 %
- Max. output power Po 350 mW
- Max. external capacitance Co 2 µF
- Typical deviation from the measuring range final value 1 %
- DNV GL-Humidity B
- Identification [Ex ia Ga] IIC
- Humidity B
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27210120
- ECLASS 7.0 27210120
- ETIM 6.0 EC002919
- UNSPSC 12.01 39121008
- UNSPSC 20.0 41112105
- ETIM 4.0 EC001446
- UNSPSC 7.0901 39121008
- UNSPSC 6.01 30211506
- UNSPSC 21.0 41112105
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨