1052459 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 1052459 Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Order configuration, freely programmable, 3-way electrical isolation, screw connection, SIL.
Phoenix Contact

Part#:1052459

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Order configuration, freely programmable, 3-way electrical isolation, screw connection, SIL.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1052459 Phoenix Contact price in the box on the right side or send a quick quote.

1052459 Product Details

  • Width
    12.5 mm
  • Degree of protection
    IP20
  • Sensor types that can be used (TC)
    B, E, J, K, N, R, S, T, L, U, C, D, A-1, A-2, A-3, M, Lr
  • Measuring range span
    Min. 50 K with thermocouple, 10% of the nominal span of the respective range with mV sources
  • Current output signal
    0 mA ... 20 mA
  • Nominal supply voltage
    24 V DC
  • Power consumption
    ≤ 1 W
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Torque
    0.5 Nm ... 0.6 Nm
  • Status display
    Green LED (supply voltage, PWR)
  • Housing material
    PA 6.6-FR
  • Standards/regulations
    GB 3836.1
  • Typical deviation from the measuring range final value
    1 %
  • DNV GL-Temperature
    B
  • DNV GL-EMC
    B
  • Temperature
    B
  • Vibration
    A
  • ECLASS 10.0.1
    27210129
  • Depth
    114.5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Input signal range
    -1000 mV ... 1000 mV
  • Temperature measuring range
    -250 °C ... 2500 °C (Range depending on the sensor type)
  • Output ripple (current)
    < 15 µAPP
  • Power dissipation
    ≤ 0.76 W
  • Connection method
    Screw connection
  • Temperature coefficient, typical
    0.01 %/K
  • Step response (0–99%)
    typ. 700 ms
  • Interference emission
    EN 61000-6-4
  • Color
    gray
  • Overvoltage category
    II
  • Noise emission
    EN 61000-6-4
  • DNV GL-Humidity
    B
  • Identification
    2
  • Humidity
    B
  • REACh SVHC
    Lead 7439-92-1
  • ETIM 6.0
    EC002919
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Test voltage
    2.5 kV AC (50 Hz, 1 min.)
  • Rated insulation voltage
    300 Vrms
  • Signal output
    Current output
  • Load/output load current output
    ≤ 600 Ω
  • Supply voltage range
    19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
  • Screw thread
    M3
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Cold point error, max.
    ± 2 K
  • Alignment span
    ± 5 %
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Designation
    Safety Integrity Level (SIL, IEC 61508)
  • Electrical isolation
    375 V (Peak value in accordance with IEC/EN 60079-11)
  • ATEX
     II 3 G Ex ec ic IIC T4 Gc
  • DNV GL-Vibration
    A
  • Additional text
    and EN 61326
  • EMC
    B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ETIM 7.0
    EC002919
  • Height
    112.5 mm
  • Ambient temperature (operation)
    49 °C
  • Altitude
    ≤ 5000 m
  • Input
    Intrinsically safe
  • Configurable/programmable
    Yes
  • Behavior in the event of a sensor error
    As per NE 43 or can be freely defined
  • Max. current consumption
    < 40 mA (24 V DC)
  • Stripping length
    7 mm
  • Conductor cross section AWG
    24 ... 14
  • Transmission error, typical
    0.1 % (E.g., for type J, 600 K span, 4 mA ... 20 mA)
  • Alignment zero
    ± 5 %
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • Degree of pollution
    2
  • Conformance
    CE-compliant, additionally EN 61326
  • IECEx
    Ex ec ic IIC T4 Gc
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Certificate
    DNV GL TAA00000AG
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 9.0
    27210129
  • ECLASS 11.0
    27210129

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

1052459

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo