1052458 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 1052458 Ex i temperature transducer: converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4…20 mA signal to a load in the safe area. Order configuration, freely programmable. 3-way isolation, SIL.
Phoenix Contact

Part#:1052458

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Ex i temperature transducer: converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4…20 mA signal to a load in the safe area. Order configuration, freely programmable. 3-way isolation, SIL.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1052458 Phoenix Contact price in the box on the right side or send a quick quote.

1052458 Product Details

  • Depth
    114.5 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Input
    Intrinsically safe
  • Measuring range span
    Min. 50 K with thermocouple, 10% of the nominal span of the respective range with mV sources
  • Current output signal
    0 mA ... 20 mA
  • Output ripple (current)
    < 15 µAPP
  • Power consumption
    ≤ 1 W
  • Connection method
    Screw connection
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • No. of channels
    1
  • Cold point error, max.
    ± 2 K
  • Alignment zero
    ± 5 %
  • Interference emission
    EN 61000-6-4
  • Color
    gray
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • Max. output voltage Uo
    3.5 V
  • Max. internal capacitance Ci
    47 µF
  • Max. external inductivity Lo
    20 µH
  • Input voltage Ui
    7 V
  • Typical deviation from the measuring range final value
    1 %
  • Conformance
    CE-compliant, additionally EN 61326
  • DNV GL-Humidity
    B
  • DNV GL-EMC
    B
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Temperature
    B
  • Width
    12.5 mm
  • Ambient temperature (operation)
    49 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Altitude
    ≤ 5000 m
  • Sensor types that can be used (TC)
    B, E, J, K, N, R, S, T, L, U, C, D, A-1, A-2, A-3, M, Lr
  • Temperature measuring range
    -250 °C ... 2500 °C (Range depending on the sensor type)
  • Configurable/programmable
    Yes
  • Behavior in the event of a sensor error
    As per NE 43 or can be freely defined
  • Nominal supply voltage
    24 V DC
  • Max. current consumption
    < 40 mA (24 V DC)
  • Screw thread
    M3
  • Torque
    0.5 Nm ... 0.6 Nm
  • Transmission error, typical
    0.1 % (E.g., for type J, 600 K span, 4 mA ... 20 mA)
  • Step response (0–99%)
    typ. 700 ms
  • Status display
    Green LED (supply voltage, PWR)
  • Designation
    EAC Ex
  • Alignment span
    ± 5 %
  • Electrical isolation
    375 V (Peak value in accordance with IEC/EN 60079-11)
  • Max. output current Io
    400 mA
  • Safety-related maximum voltage Um
    253 V AC (125 V DC, Zone 2: 3.1, 3.2 = 30 V DC)
  • Input power Pi
    550 mW
  • Noise emission
    EN 61000-6-4
  • ATEX
     I (M1) [Ex ia Ma] I
  • DNV GL-Vibration
    A
  • Certificate
    RU C-DE.AB72.B.00093/19
  • Humidity
    B
  • EMC
    B
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 9.0
    27210129
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Height
    112.5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Degree of protection
    IP20
  • Test voltage
    2.5 kV AC (50 Hz, 1 min.)
  • Rated insulation voltage
    300 Vrms
  • Input signal range
    -1000 mV ... 1000 mV
  • Signal output
    Current output
  • Load/output load current output
    ≤ 600 Ω
  • Power dissipation
    ≤ 0.76 W
  • Supply voltage range
    19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Conductor cross section AWG
    24 ... 14
  • Temperature coefficient, typical
    0.01 %/K
  • Stripping length
    7 mm
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Housing material
    PA 6.6-FR
  • Overvoltage category
    II
  • Degree of pollution
    2
  • Max. output power Po
    350 mW
  • Group
    IIC/IIB/IIA
  • Input current Ii
    100 mA
  • Standards/regulations
    GB 3626.20
  • Max. external capacitance Co
    2 µF
  • IECEx
    [Ex ia Ma] I
  • DNV GL-Temperature
    B
  • Identification
     [Ex ia Ga] IIC
  • Vibration
    A
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27210129
  • ETIM 6.0
    EC002919
  • Additional text
    and EN 61326
  • ECLASS 10.0.1
    27210129
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ETIM 7.0
    EC002919

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

1052458

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo