KFU8-GUT-EX1.D Pepperl + Fuchs Electronic Components

Pepperl + Fuchs KFU8-GUT-EX1.D Temperature Converter with Trip Values, 1-channel isolated barrier, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable
Pepperl + Fuchs

Part#:KFU8-GUT-EX1.D

Manufacturer:Pepperl + Fuchs

Product Lifecycle:Active

Get a quick Quote!

Temperature Converter with Trip Values, 1-channel isolated barrier, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable

Check out the KFU8-GUT-EX1.D Pepperl + Fuchs price in the box on the right side or send a quick quote.

Product Details

  • IECEx marking
    [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
  • Supplementary information
    Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
  • Directive 2014/34/EU
    EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012
  • IECEx certificate
    IECEx TUN 09.0019
  • Power Po
    67 mW
  • Voltage Uo
    13.1 V
  • Power
    67 mW
  • Current Io
    21 mA
  • Inputs
    terminals 1, 2, 3, 4, 6 (for passive equipment)
  • Input
    Ex ia
  • Current
    8 mA
  • Marking
    Ex-HexagonII (1)G [Ex ia Ga] IIC, Ex-HexagonII (1)D [Ex ia Da] IIIC, Ex-HexagonI (M1) [Ex ia Ma] I
  • Maximum safe voltage
    40 V DC (Attention! The rated voltage can be lower.)
  • EU-type examination certificate
    TÜV 03 ATEX 2140
  • Mounting
    on 35 mm DIN mounting rail acc. to EN 60715:2001
  • Dimensions
    40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
  • Electromagnetic compatibility
    NE 21:2007
  • Mass
    300 g
  • Ambient temperature
    -20 ... 60 °C (-4 ... 140 °F)
  • Labeling
    space for labeling at the front
  • Degree of protection
    IEC 60529:2001
  • Directive 2014/35/EU
    EN 61010-1:2010
  • Directive 2014/30/EU
    EN 61326-1:2013 (industrial locations)
  • Control elements
    Control panel
  • Configuration
    via operating buttons, via PACTware
  • Display elements
    LEDs , display
  • Output I, II/other circuits
    reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
  • Interface/power supply
    reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
  • Output I, II against eachother
    reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
  • Input/Other circuits
    reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
  • Output III/power supply
    reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
  • Current output
    max. 20 µA
  • Temperature effect
    Input: 0.005 %/K (50 ppm) of span ; current output: 0.005 %/K (50 ppm) of span
  • Sampling rate
    approx. 700 ms
  • Load
    max. 650 Ω
  • Fault signal
    downscale I ≤ 3.6 mA, upscale I ≥ 21 mA (acc. NAMUR NE43)
  • Open loop voltage
    max. 24 V DC
  • Current range
    0 ... 20 mA or 4 ... 20 mA
  • Contact loading
    250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A
  • Mechanical life
    5 x 107switching cycles
  • Energized/De-energized delay
    approx. 20 ms / approx. 20 ms
  • Potentiometer
    0.8 ... 20 kΩ
  • Measuring current
    approx. 400 µA with resistance measuring sensor
  • Output III
    Analog current output
  • Output I, II
    relay
  • Voltage
    0 ... 10 V , 2 ... 10 V , 0 ... 1 V , -100 ... 100 mV
  • Cold junction compensation
    external and internal
  • Input resistance
    ≥ 250 kΩ (0 ... 10 V), min. 1 MΩ (0 ... 1 V, -100 ... 100 mV)
  • Measurement loop monitoring
    sensor breakage, sensor short-circuit
  • Thermocouples
    type B, E, J, K, L, N, R, S, T (IEC 584-1: 1995)
  • Signal type
    Analog input
  • Safety Integrity Level (SIL)
    SIL 2
  • Connection
    terminals 23, 24
  • Lead resistance
    max. 50 Ω
  • Types of measuring
    2-, 3-, 4-wire technology
  • Programming interface
    programming socket
  • Rated voltage
    20 ... 90 V DC / 48 ... 253 V AC
  • RTD
    Pt100, Pt500, Pt1000, Ni100, Ni1000
  • Power dissipation/power consumption
    ≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA
  • Connection side
    field side

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



Related documents KFU8-GUT-EX1.D Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Pepperl + Fuchs

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Pepperl + Fuchs Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Pepperl + Fuchs Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Pepperl + Fuchs, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo