KFU8-GUT-1.D Pepperl + Fuchs Electronic Components

Pepperl + Fuchs KFU8-GUT-1.D Temperature Converter with Trip Values, 1-channel signal conditioner, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurabl
Pepperl + Fuchs

Part#:KFU8-GUT-1.D

Manufacturer:Pepperl + Fuchs

Product Lifecycle:Active

Get a quick Quote!

Temperature Converter with Trip Values, 1-channel signal conditioner, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurabl

Check out the KFU8-GUT-1.D Pepperl + Fuchs price in the box on the right side or send a quick quote.

Product Details

  • Supplementary information
    Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
  • Mass
    300 g
  • Mounting
    on 35 mm DIN mounting rail acc. to EN 60715:2001
  • Dimensions
    40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
  • Degree of protection
    IEC 60529:2001
  • Directive 2014/35/EU
    EN 61010-1:2010
  • Ambient temperature
    -20 ... 60 °C (-4 ... 140 °F)
  • Configuration
    via operating buttons, via PACTware
  • Electromagnetic compatibility
    NE 21:2007
  • Directive 2014/30/EU
    EN 61326-1:2013 (industrial locations)
  • Labeling
    space for labeling at the front
  • Control elements
    Control panel
  • Output III/power supply
    reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
  • Display elements
    LEDs , display
  • Output I, II/other circuits
    reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
  • Output I, II against eachother
    reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
  • Interface/power supply
    reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
  • Contact loading
    250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A
  • Current range
    0 ... 20 mA or 4 ... 20 mA
  • Sampling rate
    approx. 700 ms
  • Temperature effect
    Input: 0.005 %/K (50 ppm) of span ; current output: 0.005 %/K (50 ppm) of span
  • Current output
    max. 20 µA
  • Fault signal
    downscale I ≤ 3.6 mA, upscale I ≥ 21 mA (acc. NAMUR NE43)
  • Load
    max. 650 Ω
  • Output III
    Analog current output
  • Input/Other circuits
    reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
  • Mechanical life
    5 x 107switching cycles
  • Energized/De-energized delay
    approx. 20 ms / approx. 20 ms
  • Output I, II
    relay
  • Input resistance
    ≥ 250 kΩ (0 ... 10 V), min. 1 MΩ (0 ... 1 V, -100 ... 100 mV)
  • Cold junction compensation
    external and internal
  • Voltage
    0 ... 10 V , 2 ... 10 V , 0 ... 1 V , -100 ... 100 mV
  • Lead resistance
    max. 50 Ω
  • Open loop voltage
    max. 5 V with resistance measuring sensor
  • Measurement loop monitoring
    sensor breakage, sensor short-circuit
  • Thermocouples
    type B, E, J, K, L, N, R, S, T (IEC 584-1: 1995)
  • Potentiometer
    0.8 ... 20 kΩ
  • Types of measuring
    2-, 3-, 4-wire technology
  • Connection side
    field side
  • Safety Integrity Level (SIL)
    SIL 2
  • Programming interface
    programming socket
  • Connection
    terminals 23, 24
  • RTD
    Pt100, Pt500, Pt1000, Ni100, Ni1000
  • Measuring current
    approx. 400 µA
  • Power dissipation/power consumption
    ≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA
  • Rated voltage
    20 ... 90 V DC / 48 ... 253 V AC
  • Signal type
    Analog input

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



Related documents KFU8-GUT-1.D Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Pepperl + Fuchs

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Pepperl + Fuchs Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Pepperl + Fuchs Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Pepperl + Fuchs, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo