Filters
Manufacturer
Signal Isolators
part#
description
manufacturer
IM12-AI01-2I-2IU-HPR/24VDC
Isolating transducer, 2-channel, , Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IM35-11-HI/24VDC
Analog Signal Isolator, 1-channel, , Output isolator, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, TR CU
Turck
Quick Quote
IM12-TI02-2TCURTDR-2I-CPR/24VDC/CC
Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IMX12-AO01-1I-1I-HPR/24VDC/CC
Analog Signal Isolator, 1-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, HART transparent, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cFM, cUL,NEPSI, INMETRO, Kosha, TR CU EAC CMI, TIIS, Russia Pattern Approval, Installation in zone 2, SIL 2
Turck
Quick Quote
IMX12-AO01-1I-1I-HPR/24VDC
Analog Signal Isolator, 1-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, HART transparent, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cFM, cUL,NEPSI, INMETRO, Kosha, TR CU EAC CMI, TIIS, Russia Pattern Approval, Installation in zone 2, SIL 2
Turck
Quick Quote
IM12-DI03-1S-2R-S/24VDC
Isolating switching amplifier, 1-channel, , Relay output (changeover contact), Alarm output (changeover contact), Switchable between: Alarm output or signal doubling, Output mode adjustable (open-circuit/closed current mode), Input circuits monitored for wire break/short circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IM12-TI02-1TCURTDR-1I1R-C0/24VDC/CC
Temperature measuring amplifier, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IM73-12-R/230VAC
Relay coupler, 1-channel, , Output circuit: 2 relays each with 1 changeover contact, 5 A switching current at 250 VAC, Operating voltage 184…276 VDC, SIL3, , Galvanic isolation between input circuits and output circuits, TR CU
Turck
Quick Quote
IM12-DI01-2S-2PP-PR/24VDC
Isolating switching amplifier, 2-channel, , Two transistor outputs (push-pull), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IMX12-AO01-2I-2I-H0/24VDC/CC
Analog Signal Isolator, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX, IECEx, cFM, cUL,NEPSI, INMETRO, Kosha, TR CU EAC CMI, TIIS, Russia Pattern Approval, Installation in zone 2, SIL 2
Turck
Quick Quote
IMX12-FI01-1SF-1I1R-CPR/24VDC/CC
Frequency Transducer/Pulse Counter, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cFM, cUL, NEPSI, INMETRO, KOSHA, TR CU EAC CMI, TIIS, Installation in zone 2, SIL 2
Turck
Quick Quote
IMX12-DO01-2U-2U-0/24VDC/CC
Solenoid Driver, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2
Turck
Quick Quote
IMX12-FI01-1SF-1I1R-CPR/24VDC
Frequency Transducer/Pulse Counter, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cFM, cUL, NEPSI, INMETRO, KOSHA, TR CU EAC CMI, TIIS, Installation in zone 2, SIL 2
Turck
Quick Quote
IM12-AO01-1I-1I-H0/24VDC
Analog Signal Isolator, 1-channel, , Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IMXK12-AO01-1I-1I-H0/24VDC/CC
Analog Signal Isolator, 1-channel, Operating voltage 10…30 VDC, Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable cage clamp terminals, ATEX, IECEx, cULus, Use in zone 2, SIL 2
Turck
Quick Quote
IMXK12-DO01-1U-1U-0/24VCD/CC
Solenoid Driver, 1-channel, Operating voltage 10…30 VDC, Output circuits monitored for wire break and short circuit, Complete galvanic isolation, Input reverse-polarity protected, Removable cage clamp terminals, ATEX, IECEx, cULus, Use in zone 2, SIL 2
Turck
Quick Quote
IMX12-TI02-1TCURTDR-1I1R-C0/24VDC
Temperature measuring amplifier, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2
Turck
Quick Quote
IMX12-DO01-1U-1U-PR/24VDC/CC
Solenoid Driver, 1-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2
Turck
Quick Quote
IM12-FI01-2SF-2I-C0/24VDC
Frequency Transducer/Pulse Counter, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IMX12-CCM05-MTI-1I2T-HC/L
Turck - IMX12-CCM05-MTI-1I2T-HC/L
Turck
Quick Quote
Items per page: