IM33-11EX-HI/24VDC
Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, SIL2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, CCEO, Kosha, Installation in zone 2
Turck
Quick Quote
IM34-12EX-CRI/K63
Temperature measuring amplifier, 1-channel, , Connection of thermocouples acc. to IEC 751 and GOST, Connection of thermocouples acc. to IEC 584 and GOST, Parametrized via FDT / DTM, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, UL, TR CU, INMETRO, CCOE, Installation in zone 2
Turck
Quick Quote
IM43-13-SR
Trip amplifier, 1-channel, , Monitors 3 limit values at a current or voltage input, Power supply of 2-wire or 3-wire transmitters/sensors, Input circuit: 0/4…20 mA; 0/2…10 V, Output circuit: 3 independent limit value relays, Limit value relay adjusted via TEACH button, Relay outputs adjusted via buttons on the front, Universal operating voltage, Complete galvanic isolation, Input reverse-polarity protected, , C, FM, US, TR CU
Turck
Quick Quote
IMX12-DI01-2S-2T-0/24VDC
Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, Kosha, TIIS, TR CU EAC, DNV, GL, Installation in zone 2, SIL 2
Turck
Quick Quote
IM12-AI01-2I-2IU-HPR/24VDC/CC
Isolating transducer, 2-channel, , Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IM12-FI01-1SF-1R-0/24VDC
Frequency Transducer/Pulse Counter, 1-channel, Operating voltage 10…30 VDC, Input circuits monitored for wire break and short circuit, Parameterized via DIP/rotary coding switch, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Installation in Zone 2, SIL 2
Turck
Quick Quote
IMX12-DI03-1S-1NAM1R-0/24VDC
Isolating switching amplifier, 1-channel, , Relay output (changeover), NAMUR Repeater, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2
Turck
Quick Quote
IM33-11-HI/24VDC
Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, SIL2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, TR CU
Turck
Quick Quote
IMX12-DO01-2U-2U-PR/24VDC
Solenoid Driver, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2
Turck
Quick Quote
IM12-TI02-2TCURTDR-2I-C0/24VDC
Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IMX12-AO01-1I-1I-H0/24VDC
Analog Signal Isolator, 1-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX, IECEx, cFM, cUL,NEPSI, INMETRO, Kosha, TR CU EAC CMI, TIIS, Russia Pattern Approval, Installation in zone 2, SIL 2
Turck
Quick Quote
IM33-12-HI/24VDC
Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, SIL 2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, TR CU
Turck
Quick Quote
IM12-DI01-2S-2R-0/24VDC
Isolating switching amplifier, 2-channel, , 2 relay outputs (complementary contact), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IMX12-DI03-1S-2R-S/24VDC
Isolating switching amplifier, 1-channel, , Relay output (changeover), Alarm output (changeover), Switchable: Alarm output or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2
Turck
Quick Quote
IMX12-DI03-1S-1NAM1R-PR/24VDC/CC
Isolating switching amplifier, 1-channel, , Relay output (changeover), NAMUR Repeater, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2
Turck
Quick Quote
IMX12-DI01-2S-2R-PR/24VDC/CC
Isolating switching amplifier, 2-channel, , 2 relay outputs (complementary contact), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, Kosha, TIIS, TR CU EAC, DNV, GL, Installation in zone 2, SIL 2
Turck
Quick Quote
IM1-22EX-R/230VAC
Isolating switching amplifier, 2-channel, , Adjustable output mode (NO/NC), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, ATEX, TR CU, Installation in zone 2
Turck
Quick Quote
IM33-14EX-CDRI
Isolating transducer, 1-channel, , Monitoring of analog values and ranges according to over and underrange, Line monitoring, Parameterized via PC (FDT/DTM), front-panel switch or HART, Ring buffer for up to 8000 measured values, Display, Power supply of 2 and 3-wire measuring transducers, Suited for active and passive signals, Output circuit: 0/4…20 mA, reversible, 3 relay outputs, Universal operating voltage, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, TR CU, KOS
Turck
Quick Quote
IM12-22EX-R/24VDC
Isolating switching amplifier, 2-channel, , Output mode adjustable (NO/NC mode), Multiplexing of signals possible, Complete galvanic isolation, Input reverse-polarity protected, ATEX, C, FM, US, TR CU
Turck
Quick Quote
IM21-14EX-CDTRI
Rotation speed monitor, 1-channel, , Monitoring of limit values and ranges according to over and underrange, Operating range 0.06…600,000 min, -1, Pulse output Ex [ic Gc] II C/II B, Parameterized via PC (FDT/DTM), front-panel switch or HART, Ring buffer for up to 8000 measured values, Display, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, TR CU, NEPSI, TIIS, Kosha, Installation in zone 2
Turck
Quick Quote