IMX12-DI01-2S-2PP-0/24VDC/CC
Isolating switching amplifier, 2-channel, , Two transistor outputs (push-pull), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX, IECEx, NEPSI, cUL, cFM INMETRO, Kosha, TR CU EAC, Installation in zone 2, SIL 2
Turck
Quick Quote
IMX12-DI01-2S-2PP-PR/24VDC
Isolating switching amplifier, 2-channel, , Two transistor outputs (push-pull), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM INMETRO, Kosha, TR CU EAC, Installation in zone 2, SIL 2
Turck
Quick Quote
IM1-451-T
Isolating switching amplifier, 4-channel, , 5 transistor outputs, short-circuit proof, potential-free and reverse-polarity protected, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Common alarm output, Complete galvanic isolation, Input reverse-polarity protected, TR CU
Turck
Quick Quote
IMC-AO-11EX-I/L
Analog Signal Isolator, 1-channel, , Analog signal isolator, 1-channel, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, Protection class IP67, Connection with M12 male connectors, ATEX, C, FM, US, IECEx, Use in Zone 2/22
Turck
Quick Quote
IM36-22EX-I
Potentiometer Amplifier, 2-channel, , Transmission of potentiometer signals from the Ex area, Potentiometer, nominal resistance: 0.8…100 kΩ, Output circuit: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, TR CU, KOSHA, Installation in zone 2
Turck
Quick Quote
IMX12-FI01-2SF-2I-C0/24VDC/CC
Frequency Transducer/Pulse Counter, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX, IECEx, cFM, cUL, NEPSI, INMETRO, KOSHA, TR CU EAC CMI, TIIS, Installation in zone 2, SIL 2
Turck
Quick Quote
IM12-DI01-2S-2R-0/24VDC/CC
Isolating switching amplifier, 2-channel, , 2 relay outputs (complementary contact), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IM34-11EX-CI/K60
Temperature measuring amplifier, 1-channel, , Input for Pt100/ Ni100 resistors, thermocouples and millivolt signals in 2, 3 or 4-wire technology, Suitable for fast temperature changes, starting with a thermal gradient of 200 µV/s, Parameterized using PACTware, Output: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, UL, TR CU, INMETRO, CCOE, Installation in zone 2
Turck
Quick Quote
IM12-AO01-1I-1I-HPR/24VDC/CC
Analog Signal Isolator, 1-channel, , Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IM12-DI03-1S-1NAM1T-0/24VDC/CC
Isolating switching amplifier, 1-channel, , Transistor output (≤ 10 kHz), NAMUR repeater, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IMX12-DI01-2S-2T-0/24VDC/CC
Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, Kosha, TIIS, TR CU EAC, DNV, GL, Installation in zone 2, SIL 2
Turck
Quick Quote
IM33-FSD-EX/L
Isolating transducer for fire and smoke detectors, 2-channel, , Isolating transducer without auxiliary power, Power supply for fire and smoke detectors, Signal transmission: 0…40 mA, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, ATEX, C, FM, US
Turck
Quick Quote
IM12-DI03-1S-1NAM1R-PR/24VDC
Isolating switching amplifier, 1-channel, , Relay output (changeover contact), NAMUR repeater, Output mode adjustable (open-circuit/closed current mode), Input circuits monitored for wire break/short circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IM12-AI01-1I-2IU-HPR/24VDC
Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IMC-AIA-11EX-I/24VDC
Isolating transducer, 1-channel, , Isolating transducer, 1-channel, Output circuit: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, Protection class IP67, Connection with M12 male connectors, ATEX, C, FM, US, IECEx, Use in Zone 2/22
Turck
Quick Quote
IM12-AI01-1I-2IU-H0/24VDC
Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IM73-22EX-R/24VUC
Relay coupler, 2-channel, , Relay coupler for switching of intrinsically safe and current limited circuits, High-quality reed relays with rhodium contacts, Switching frequency up to 50 Hz, Galvanic isolation between input and output circuits, ATEX, TR CU, Installation in zone 2
Turck
Quick Quote
IM12-AI01-1I-2IU-HPR/24VDC/CC
Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
IM34-12EX-CRI
Temperature measuring amplifier, 1-channel, , Input for Pt100/ Ni100 resistors, thermocouples and millivolt signals in 2, 3 or 4-wire technology, Output circuit: 0/4…20 mA, limit value relay, Parameterized via PC (FDT / DTM), Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, UL, TR CU, INMETRO, Installation in zone 2
Turck
Quick Quote
IM12-AO01-2I-2I-HPR/24VDC
Analog Signal Isolator, 2-channel, , Output circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Turck
Quick Quote
Items per page: