Filters
Manufacturer
More in this category
Electrical Measuring & Monitoring Instruments
part#
description
manufacturer
2905321
VARIOFACE front adapter, for Honeywell C300, series C I/O, max. 1 x 16 channels with configuration plug and 37-pos. D-SUB connector
Phoenix Contact
STOCK: 11
Fast shipping2838241
PT protective connector with protective circuit for two 2-wire floating signal circuits. 5 V DC nominal voltage. HART-compatible.
Phoenix Contact
STOCK: 10
Fast shipping2942124
Setpoint value potentiometer, to set setpoints individually, resistance value 10 kΩ
Phoenix Contact
STOCK: 11
Fast shipping2800035
Surge protection for one floating signal circuit in screw-on module with IP67 degree of protection for sensor heads, connection: ½-inch 14 NPT. Tested in accordance with types of protection in Ex areas Ex d / Ex tD / Ex ia IIC / Ex iaD. Suitable for use i
Phoenix Contact
STOCK: 16
Fast shipping2905249
Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Push-in connection technology, standard configuration
Phoenix Contact
STOCK: 25
Fast shipping2905028
Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Push-in connection technology, standard configuration.
Phoenix Contact
STOCK: 54
Fast shipping2906595
VIP base module with input/output accessories (IOA) provide universal channel configuration. This module with the D-SUB 25 connector is pin compatable to the Foxboro I/A series DCS.
Phoenix Contact
STOCK: 11
Fast shipping2908788
VIP base module with input/output accessories (IOA) provide universal channel configuration. This module with the D-SUB 50 connector is pin compatable to the Tricon CX series DCS.
Phoenix Contact
STOCK: 9
Fast shipping2908209
Surge protection, consisting of protective plug and base element, with integrated status indicator for two signal wires with common reference potential, e.g., Digital IN/OUT. Indirect grounding via gas-filled surge arrester.
Phoenix Contact
STOCK: 9
Fast shipping2865997
NAMUR signal conditioners for operating proximity sensors and switches. The signals are transmitted to the control level via relay output (changeover contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, with screw connection.
Phoenix Contact
STOCK: 8
Fast shipping2839282
Base element for protective plug PT, for mounting on NS 35/7.5 and NS 35/15, housing width: 17.5 mm
Phoenix Contact
STOCK: 8
Fast shipping2865450
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Phoenix Contact
STOCK: 2
Fast shipping2838306
Protective plug PT with protective circuit for 4 conductors of signal circuits grounded on one side. Nominal voltage: 5 V DC
Phoenix Contact
STOCK: 7
Fast shipping2864095
MCR potiposition transducer for conversion of potentiometer positions into a standard analog signal, 0 Ω input... 100 Ω to 0 kΩ ... 100 kΩ
Phoenix Contact
STOCK: 5
Fast shipping2277022
Bus-bar current transformer, 100 A AC primary current; 5 A AC secondary current; accuracy class 1; 2.5 VA rated power
Phoenix Contact
STOCK: 7
Fast shipping2865382
Ex i measuring transducer repeater power supply, 2-channel; HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, screw connection, up to SIL 3, PL
Phoenix Contact
STOCK: 8
Fast shipping2924304
2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in conn
Phoenix Contact
STOCK: 6
Fast shipping2811446
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), screw connection, SIL.
Phoenix Contact
STOCK: 6
Fast shipping2907715
Safety divider provides physical separation between field terminals and power bus terminals on VIP base module
Phoenix Contact
STOCK: 6
Fast shipping2277051
Bus-bar current transformer, 400 A AC primary current; 5 A AC secondary current; accuracy class 1; 5 VA rated power
Phoenix Contact
STOCK: 6
Fast shipping
Items per page:
Electrical Measuring & Monitoring Instruments
General Guide & Overview
Electrical measuring instruments play a crucial role in ensuring the safety and efficiency of electrical systems. From measuring voltage and current to diagnosing electrical issues, these instruments provide valuable information for maintenance and troubleshooting purposes.
There are various types of electrical measuring instruments available, each designed for specific applications. Whether you are a professional electrician, an engineer, or a DIY enthusiast, understanding these instruments is essential when working with electricity.
In this guide, we will provide an overview of different electrical measuring instruments and their functions. From multimeters to megohmmeters, we will explore the types of instruments used in electrical testing and the safety precautions associated with them.
By the end of this guide, you will have a better understanding of the various tools and devices available for measuring and monitoring electrical parameters. Whether you are a beginner or an experienced professional, this guide will serve as a valuable resource in your electrical testing journey.
Multimeter
A multimeter, also known as a Volt-Ohm meter (VOM), is a handheld device that combines multiple measurement functions, including voltage, current, resistance, and frequency, into a single unit.
The multimeter is a versatile device that can be used to test and troubleshoot electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems. Its portable and compact design makes it convenient to carry and use in different locations or on the go.
With a multimeter, you can accurately measure voltage to check if electrical circuits are delivering the expected power. It allows you to determine the current flowing through a circuit, helping you analyze the performance and efficiency of electrical devices. The resistance measurement function helps identify faulty or damaged components in a circuit, allowing for timely repairs.
In addition, a multimeter can measure frequency, which is essential for diagnosing issues in electrical systems that rely on specific frequency ranges, such as motor controls and power supplies.
With its ability to measure voltage, current, resistance, and frequency, this handheld device helps you ensure the proper functioning of electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems, making it an essential addition to any toolkit.
Megohmmeter
A megohmmeter, commonly known as a "megger," is a specialized type of ohmmeter used to measure the electrical resistance of insulators. It plays a crucial role in ensuring the safety and efficiency of electrical systems. Megohmmeters are designed to accurately measure resistance values ranging from several megohms to several million megohms, allowing technicians to evaluate the insulation properties of various equipment and components.
Megohmmeters are extensively used in industries such as power generation, transmission, and distribution. They are particularly valuable for assessing the insulation integrity of critical equipment like circuit breakers, transformers, switchgear, and cables. By measuring the resistance, technicians can identify potential issues like degraded insulation, moisture ingress, or other faults that may compromise the safety and functionality of electrical systems.
Unlike standard ohmmeters, which measure low resistance values, megohmmeters utilize high voltage levels to test the insulation properties of materials. This high voltage helps to identify leaks or weak spots in the insulation and ensures that the materials meet the required safety standards. Megohmmeters provide valuable insights into the electrical health of different components, allowing technicians to diagnose problems and take preventive actions.
When using a megohmmeter, it is important to follow safety precautions and use the appropriate personal protective equipment (PPE) to protect against potential electrical hazards. Technicians should carefully follow the manufacturer's instructions and ensure that the equipment is properly calibrated and maintained for accurate measurements. By utilizing megohmmeters in regular testing and maintenance procedures, electrical systems can operate at their optimum level, ensuring reliable performance and reducing the risk of malfunctions and costly downtime.
Safety Precautions and Conclusion
Before using a multimeter or any electrical testing equipment, it is crucial to understand the necessary safety precautions and guidelines. This ensures not only the accuracy of the measurements but also the personal safety of the operator.
To begin, it is essential to check the multimeter's electrical parameters, such as voltage range and current capacity, to ensure they are suitable for the intended application. Additionally, understanding the multimeter's Category (CAT) rating is crucial in assessing its safety level for various electrical environments. The CAT rating indicates the maximum voltage and current the multimeter can safely withstand.
Furthermore, performing a visual inspection of the multimeter before use is vital. One must check for any physical damage, loose connections, or worn-out leads or probes. If any defects are identified, the multimeter should be repaired or replaced to avoid potential hazards.
When working with electricity, personal protective equipment (PPE) is essential. This may include insulating gloves, safety glasses, and non-conductive footwear. Using PPE not only protects against electrical shock but also ensures overall safety in case of accidents.
In conclusion, adhering to proper safety precautions and guidelines when using multimeters or any electrical testing equipment is of utmost importance. By considering multimeter CAT ratings, performing visual inspections, and wearing appropriate PPE, the operator can minimize the risk of electrical hazards. These preventive measures ensure the accurate and safe functioning of the multimeter, allowing for reliable measurements and effective troubleshooting in various electrical systems. Remember, safety should always be the top priority when working with electricity.
FAQ
What is electrical testing and why is it important?
Electrical testing involves applying voltage or current to a circuit and comparing the measured value to an expected result. It is important because it helps verify the calculations within a circuit and diagnose electrical issues.
What are some commonly used electrical measuring instruments?
Some commonly used electrical measuring instruments include multimeters, megohmmeters, low-resistance ohmmeters, hipotential test sets, high current test sets, secondary test sets, relay test sets, power factor test sets, and winding resistance test sets.
What is a multimeter used for?
A multimeter, also known as a Volt-Ohm meter (VOM), is a handheld device that combines multiple measurement functions, such as voltage, current, resistance, and frequency, into a single unit. It is primarily used to diagnose electrical issues in a wide range of industrial and household devices.
What is a megohmmeter used for?
A megohmmeter, commonly known as a "megger," is a specialized type of ohmmeter used to measure the electrical resistance of insulators. It is frequently used to measure the insulation of various types of equipment, including circuit breakers, transformers, switchgear, and cables.
What safety precautions should be followed when using electrical measuring instruments?
Before using any electrical testing equipment, it is important to understand the electrical parameters and safety precautions associated with them. This includes checking for appropriate CAT ratings, understanding the IP codes for dust and water resistance, and visually inspecting the meter for any physical damage. It is also crucial to take proper safety measures when working with electricity, such as using personal protective equipment (PPE) and following specific guidelines to prevent electrical hazards.