Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

LTMR100PBD Schneider Electric Industrial Automation Components

Schneider Electric LTMR100PBD Schneider Electric LTMR100PBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The device offers multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and Custom mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and more. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current and voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, number of starts per hour, last start I max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. The LTMR100PBD uses 3 measurement current transformers with a screw-clamp connection type and communicates via Profibus protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, earth fault, and frequent starting. Rated for currents from 5-100 A, it offers adjustable protection settings for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, current load limit variations, and earth fault. The supply voltage is 24 V DC with a rated voltage for AC phase-to-phase of 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, catering to a wide range of monitoring and protection needs.
Schneider Electric

Part#:LTMR100PBD

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric LTMR100PBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The device offers multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and Custom mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and more. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current and voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, number of starts per hour, last start I max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. The LTMR100PBD uses 3 measurement current transformers with a screw-clamp connection type and communicates via Profibus protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, earth fault, and frequent starting. Rated for currents from 5-100 A, it offers adjustable protection settings for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, current load limit variations, and earth fault. The supply voltage is 24 V DC with a rated voltage for AC phase-to-phase of 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, catering to a wide range of monitoring and protection needs.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LTMR100PBD Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Protection Type
    Load fluctuation Reverse polarity protection Locked rotor Thermal protection Overload (long time) Overload Power factor variation Earth-leakage protection Thermal overload protection Phase unbalance Phase
  • Measurement Accuracy
    5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 5 % active and reactive power 0,02
  • Metering Type
    Imbalance current Temperature Average current Iavg Phase current I1, I2, I3 RMS Earth-fault current
  • Electromagnetic Compatibility
    Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
  • [Ui] Rated Insulation Voltage
    690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
  • Connections - Terminals
    Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2
  • Permissible Power
    480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
  • Associated Fuse Rating
    4 A gG output 0.5 A gG control circuit
  • Contacts Type And Composition
    1 NO + 1 NC fault signal 3 NO
  • Network And Machine Diagnosis Type
    Trip context information Event recording Waiting time after overload tripping Running hours counter/operating time Remaining operating time before overload tripping Fault recording Motor control command recording Trip hi
  • Bus Type
    Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, SUB-D 9 2 shielded twisted pairs, type A Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, terminal block 2 shielded twisted pairs, type A
  • Load Current
    5 A 250 V AC logic output 5 A 30 V DC logic output
  • Depth
    4.82 in (122.5 mm)
  • Width
    3.58 in (91 mm)
  • Compatibility Code
    LTMR
  • Height
    2.40 in (61 mm)
  • Pollution Degree
    3
  • Web Services
    Web server
  • Net Weight
    1.17 lb(US) (0.53 kg)
  • Overvoltage Category
    III
  • Tightening Torque
    Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
  • Connection Pitch
    0.20 in (5.08 mm)
  • Maximum Operating Rate
    1800 cyc/h
  • Current State 1 Guaranteed
    Logic input < 15 V 2...15 mA 15 ms
  • Maximum Output Switching Frequency
    2 Hz
  • Logic Input Number
    6
  • Current State 0 Guaranteed
    Logic input < 5 V <= 15 mA 5 ms
  • Short-Circuit Withstand
    100 kA EN/IEC 60947-4-1
  • Input Current
    7 mA
  • Communication Port Protocol
    Profibus DP
  • Current Consumption
    56...127 mA
  • Supply Voltage Limits
    20.4…26.24 V DC
  • Product Or Component Type
    Motor controller
  • Device Application
    Equipment monitoring and control
  • Device Short Name
    LTMR
  • Product Name
    TeSys T
  • Range
    TeSys
  • [Us] Rated Supply Voltage
    24 V DC
  • Measurement Current
    5…100 A

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

This item can ship within 5 days!

LTMR100MBD Part Image. Manufactured by Schneider Electric.

LTMR100MBD

$588.72

Verified stock: 1

Schneider Electric LTMR100MBD, part of the LTMR (TeSys T) sub-range, is designed for motor management with a variety of control modes including local via terminal block, local via HMI terminal, and remote via network. It supports operating modes such as overload, independent, reverser, 2-step, 2-speed, and custom mode. The part offers comprehensive fault management capabilities with manual, automatic, and remote reset options, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics cover time to trip and time to restart, while system operating statistics include run, on, start, alarm, and fault indicators. The connection type is 3 measurement current transformers with screw-clamp terminals, and it uses the Modbus communication protocol. It is a 3 Pole device with protection functions for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. Rated current ranges from 5-100 A with protection settings adjustable for various conditions. The supply voltage is 24 V DC, and the rated voltage for AC phase-to-phase is up to 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, accommodating a wide range of monitoring and protection needs for motor management.

Schneider Electric

LTMR08DFM Part Image. Manufactured by Schneider Electric.

LTMR08DFM

Verified stock: 0

Schneider Electric LTMR08DFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation via network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and more. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, starts per hour, last start I max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. The connection type is through 3 measurement current transformers with a screw-clamp mechanism. It uses the DeviceNet communication protocol and is a 3 Pole device. Protection functions include thermal overload, motor temperature monitoring with up to 3 sensors, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, and earth fault detection. It also features protection against frequent starting to prevent motor overheating. The rated current ranges from 0.4-8 A, with a maximum of 800 A using CT. Protection settings are comprehensive, covering thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, current load limit variations, and earth fault with specific thresholds and response times. The supply voltage is AC 100-240 V, with a rated voltage for phase-to-phase of 690 V at 50-60Hz. The minimum current is 0.4 A, and the maximum is 8 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.

Schneider Electric

LTMR08PFM Part Image. Manufactured by Schneider Electric.

LTMR08PFM

Verified stock: 0

Schneider Electric LTMR08PFM, part of the LTMR (TeSys T) sub-range, is designed for motor management with a variety of control modes including local via terminal block, local via HMI terminal, and remote via network. It supports operating modes such as overload, independent, reverser, 2-step, 2-speed, and custom mode. The part offers comprehensive fault management capabilities with manual, automatic, and remote reset options, alongside protection fault, alarm, diagnostic fault, and motor control function counters. It also includes fault history and diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, and motor control commands. The LTMR08PFM features a connection type of 3 measurement current transformers with screw-clamp terminals and uses the Profibus communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. It also includes a frequent starting protection mechanism. The rated current ranges from 0.4-8 A, with a maximum of 800 A using CT, and offers various protection settings for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, current load limit variations, and earth fault. The supply voltage is AC 100-240 V, with a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz. The minimum current is 0.4 A, and the maximum is 8 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.

Schneider Electric

LTMR08CFM Part Image. Manufactured by Schneider Electric.

LTMR08CFM

Verified stock: 0

Schneider Electric LTMR08CFM, part of the LTMR (TeSys T) sub-range, is designed for motor management with a variety of control modes including local operation via terminal block or HMI terminal, and remote operation via network. It supports multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and "Custom" mode. The part offers comprehensive fault management capabilities with manual, automatic, and remote reset options, alongside detailed fault statistics including protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and more. Fault diagnostics cover internal watchdog fault, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics are provided, including the number of motor control commands, operating time, number of starts per hour, last start I max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. The LTMR08CFM features a 3-pole configuration with a screw-clamp connection type and utilizes 3 measurement current transformers for the control circuit. It supports the CANopen communication protocol. Protection functions include thermal overload, motor temperature monitoring with up to 3 sensors, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and protection against frequent starting. Rated current ranges from 0.4-8 A, with a maximum of 800 A using CT. Protection settings are extensive, covering thermal overload classes, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, current load limit variations, and earth fault parameters. The supply voltage is AC 100-240 V, with a rated voltage for phase-to-phase operation at 50-60Hz being 690 V. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.

Schneider Electric

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo