LTMR100DBD Schneider Electric Industrial Automation Components
Part#:LTMR100DBD
Manufacturer:Schneider Electric
Product Lifecycle:Active
Get a quick Quote!
Schneider Electric LTMR100DBD, part of the LTMR (TeSys T) sub-range, is designed for motor management with a variety of control modes including local via terminal block, local via HMI terminal, and remote via network. It supports operating modes such as overload, independent, reverser, 2-step, 2-speed, and "Custom" mode. The device offers comprehensive fault management capabilities with manual, automatic, and remote reset options, alongside detailed fault statistics including protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, duration of last start, while thermal overload statistics cover time to trip and time to restart. System operating statistics include run, on, start, alarm, and fault statuses. The connection type is 3 measurement current transformers with a screw-clamp control circuit. It uses the DeviceNet communication protocol and is a 3 Pole device. Protection functions include thermal overload, motor temperature monitoring with up to 3 sensors in series, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and protection against frequent starting. Rated current ranges from 5-100 A with protection settings adjustable for various conditions. Supply voltage is DC 24 V, and the rated voltage for AC phase-to-phase is 690 V at 50-60Hz. Measurement functions cover a wide range of current and temperature monitoring capabilities, ensuring comprehensive protection and management of motor operations.
About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LTMR100DBD Schneider Electric price in the box on the right side or send a quick quote.
Product Details
- Protection Type Earth-leakage protection Overload Reverse polarity protection Thermal protection Overload (long time) Load fluctuation Phase failure Thermal overload protection Power factor variation Locked rotor Phase un
- Network And Machine Diagnosis Type Running hours counter/operating time Starting current and time Trip context information Remaining operating time before overload tripping Fault recording Phase fault and earth fault trip counters Event recording Trip his
- Measurement Accuracy 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 5 % active and reactive power 0,02
- Metering Type Temperature Average current Iavg Imbalance current Earth-fault current Phase current I1, I2, I3 RMS
- Electromagnetic Compatibility Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
- [Ui] Rated Insulation Voltage
690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508- Connections - Terminals
Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2- [Uimp] Rated Impulse Withstand Voltage
6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1- Permissible Power
480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)- Contacts Type And Composition
1 NO + 1 NC fault signal 3 NO- Associated Fuse Rating
4 A gG output 0.5 A gG control circuit- Load Current
5 A 250 V AC logic output 5 A 30 V DC logic output- Depth
4.82 in (122.5 mm)- Net Weight
1.17 lb(US) (0.53 kg)- Web Services
Web server- Compatibility Code
LTMR- Height
2.40 in (61 mm)- Width
3.58 in (91 mm)- Connection Pitch
0.20 in (5.08 mm)- Overvoltage Category
III- Pollution Degree
3- Tightening Torque
Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)- Maximum Operating Rate
1800 cyc/h- Current State 0 Guaranteed
Logic input < 5 V <= 15 mA 5 ms- Current State 1 Guaranteed
Logic input < 15 V 2...15 mA 15 ms- Maximum Output Switching Frequency
2 Hz- Logic Input Number
6- Short-Circuit Withstand
100 kA EN/IEC 60947-4-1- Input Current
7 mA- Communication Port Protocol
DeviceNet- Bus Type
DeviceNet ISO 1198 1...64 125...500 kbit/s, terminal block 4 twisted shielded pairs cable- Supply Voltage Limits
20.4…26.24 V DC- Current Consumption
56...127 mA- [Us] Rated Supply Voltage
24 V DC- Measurement Current
5…100 A- Device Application
Equipment monitoring and control- Product Or Component Type
Motor controller- Device Short Name
LTMR- Product Name
TeSys T- Range
TeSysProduct condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents LTMR100DBD Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Schneider Electric
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
- [Ui] Rated Insulation Voltage
Schneider Electric Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨