Bolt connection terminal block, nom. voltage: 800 V, nominal current: 125 A, connection method: Bolt connection, number of connections: 2, number of positions: 1, width: 17 mm, color: gray, mounting type: NS 35/7,5, NS 35/15, NS 32
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3075896 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of connections 2
- Insulating material group I
- Nominal current IN 125 A
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Result of tight fit on support Test passed
- Result of voltage-drop test Test passed
- Result of thermal test Test passed
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Width 17 mm
- Height NS 35/7,5 49.8 mm
- Connection in acc. with standard CUL
- Short-time current 4.2 kA
- Test spectrum Service life test category 1, class B, body mounted
- Potentials 1
- Flammability rating according to UL 94 V0
- Overvoltage category III
- Nominal voltage UN 800 V
- Result of power-frequency withstand voltage test Test passed
- Setpoint 10 N
- Short circuit stability result Test passed
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- ASD level 1.857 (m/s2)2/Hz
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- End cover width 2.2 mm
- Pitch 17 mm
- Cable lug connection according to standard DIN 46237:1970-07
- AWG min 14
- Bolt diameter 6 mm
- Tightening torque, min 3.2 Nm
- Ambient temperature (assembly) -5 °C ... 70 °C
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 6.0 27141100
- ETIM 3.0 EC000897
- UNSPSC 6.01 30211811
- Number of positions 1
- Color gray
- Degree of pollution 3
- Maximum power dissipation for nominal condition 4.06 W
- Open side panel No
- Tight fit on carrier NS 32/NS 35
- Result of temperature-rise test Test passed
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Acceleration 5g
- Shock test result Test passed
- Shock form Half-sine
- Surface flammability NFPA 130 (ASTM E 162) passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Height NS 35/15 57.3 mm
- Height NS 32 54.8 mm
- Connection method Bolt connection
- Additional text only use with shrink sleeve
- AWG max 10
- Tightening torque max 3.7 Nm
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 4.0 27141100
- ECLASS 4.1 27141100
- ECLASS 7.0 27141120
- ETIM 6.0 EC000897
- UNSPSC 13.2 39121410
- UNSPSC 19.0 39121410
- Number of levels 1
- Nominal cross section 35 mm²
- Insulating material PA
- Rated surge voltage 8 kV
- Maximum load current 125 A (with 35 mm² conductor cross section)
- Result of surge voltage test Test passed
- Power frequency withstand voltage setpoint 2 kV
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Conductor cross section short circuit testing 35 mm²
- Oscillation, broadband noise test result Test passed
- Test duration per axis 5 h
- Shock duration 30 ms
- Number of shocks per direction 3
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Length 80.8 mm
- Connection 1 level
- Stripping length The stripping length depends on the specification provided by the cable lug manufacturer.
- Max. cross section for cable lug connection 6 mm²
- Cable lug width, max. 11 mm
- Screw thread M6
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 10.0.1 27141120
- ECLASS 5.0 27141100
- ECLASS 9.0 27141120
- ETIM 4.0 EC000897
- UNSPSC 7.0901 39121410
- UNSPSC 18.0 39121410
- Min. cross section for cable lug connection 2.5 mm²
- Hole diameter, min. 6.5 mm
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 11.0 27141120
- ECLASS 5.1 27141100
- ETIM 2.0 EC000897
- ETIM 7.0 EC000897
- UNSPSC 12.01 39121410
- UNSPSC 21.0 39121410
- UNSPSC 11 39121410
- UNSPSC 20.0 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$4.44
Stock:
1440
Select Qty:
$4.44
$4.44 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨