3049039 Phoenix Contact Terminal Blocks
Part#:3049039
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 27
Nov 2, 2024
Test disconnect terminal block, nom. voltage: 1000 V, nominal current: 41 A, connection method: Bolt connection, length: 91.4 mm, width: 16.3 mm, color: gray, mounting: NS 35/7,5, NS 35/15
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3049039 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of connections 2
- Insulating material PA
- Overvoltage category III
- Maximum load current 41 A (with 6 mm² conductor cross section)
- Finger protection guaranteed
- Setpoint 5 N
- Short-time current 0.72 kA
- Test spectrum Service life test category 1, class B, body mounted
- Shock test result Test passed
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Width 16.3 mm
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Connection method Bolt connection
- Hole diameter, min. 5.3 mm
- Bolt diameter 5 mm
- Permissible humidity (storage/transport) 30 % ... 70 %
- Note Note: the BE-RT... path extension is to be used for non-insulated cable lugs (see accessories).
- Maximum power dissipation for nominal condition 1.31 W
- Nominal voltage UN 1000 V (Rated voltage for open disconnect point 500 V)
- Result of surge voltage test Test passed
- Result of tight fit on support Test passed
- Result of temperature-rise test Test passed
- Proof of thermal characteristics (needle flame) effective duration 30 s
- ASD level 1.857 (m/s2)2/Hz
- Number of shocks per direction 3
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Potentials 1
- Color gray
- Rated surge voltage 6 kV
- Shock protection test specification IEC 60529:2001-02
- Open side panel Yes
- Result of power-frequency withstand voltage test Test passed
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Result of thermal test Test passed
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Height NS 35/7,5 51 mm
- Connection in acc. with standard CUL
- Cable lug connection according to standard DIN 46237:1970-07
- Cable lug width, max. 10 mm
- Ambient temperature (assembly) -5 °C ... 70 °C
- Flammability rating according to UL 94 V0
- Degree of pollution 3
- Nominal current IN 41 A
- Power frequency withstand voltage setpoint 1.89 kV
- Number of levels 1
- Result of voltage-drop test Test passed
- Short circuit stability result Test passed
- Oscillation, broadband noise test result Test passed
- Test duration per axis 5 h
- Shock form Half-sine
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- End cover width 2.2 mm
- Connection 1 level
- AWG min 18
- Screw thread M4
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 10.0.1 27141126
- ECLASS 11.0 27141126
- UNSPSC 7.0901 39121410
- ETIM 4.0 EC000902
- UNSPSC 21.0 39121410
- Area of application Railway industry
- Back of the hand protection guaranteed
- Tight fit on carrier NS 35
- Conductor cross section short circuit testing 6 mm²
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Acceleration 5g
- Shock duration 30 ms
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height NS 35/15 58.5 mm
- Max. cross section for cable lug connection 6 mm²
- Tightening torque, min 1.5 Nm
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- AWG max 10
- Tightening torque max 1.8 Nm
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27141100
- ECLASS 5.1 27141100
- Length 91.4 mm
- ECLASS 7.0 27141126
- ETIM 6.0 EC000902
- UNSPSC 12.01 39121410
- UNSPSC 18.0 39121410
- ECLASS 6.0 27141100
- ETIM 2.0 EC000902
- UNSPSC 13.2 39121410
- Min. cross section for cable lug connection 1 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.0 27141100
- UNSPSC 6.01 30211811
- Stripping length The stripping length depends on the specification provided by the cable lug manufacturer.
- ETIM 3.0 EC000902
- UNSPSC 20.0 39121410
- Nominal cross section 6 mm²
- Insulating material group I
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- ECLASS 5.0 27141100
- ECLASS 9.0 27141126
- ETIM 7.0 EC000902
- UNSPSC 11 39121410
- UNSPSC 19.0 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$8.64
Stock:
27
Select Qty:
$8.64
$8.64 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨