Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3046485 Phoenix Contact Terminal Blocks

Phoenix Contact 3046485 Disconnect terminal block, nom. voltage: 500 V, nominal current: 20 A, connection method: Screw connection, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, length: 57.8 mm, width: 8.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3046485

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Disconnect terminal block, nom. voltage: 500 V, nominal current: 20 A, connection method: Screw connection, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, length: 57.8 mm, width: 8.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3046485 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Nominal current IN
    20 A
  • Back of the hand protection
    guaranteed
  • Surge voltage test setpoint
    7.2 kV
  • Result of flexion and pull-out test
    Test passed
  • Result of voltage-drop test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Static insulating material application in cold
    -60 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/15
    55 mm
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible min.
    0.2 mm²
  • 2 conductors with same cross section, solid max.
    2.5 mm²
  • Internal cylindrical gage
    A5
  • Potentials
    1
  • Color
    gray
  • Maximum load current
    20 A (with 10 mm² conductor cross section)
  • Open side panel
    No
  • Result of surge voltage test
    Test passed
  • Bending test turns
    135
  • Setpoint
    5 N
  • Requirements, voltage drop
    U1 ≤ 6,4 mV (1,6 mV x number of conductorclamping units or disconnect unit contactpoints)U2 ≤ 1,5 x U1
  • Conductor cross section short circuit testing
    2.5 mm²
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of shocks per direction
    3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Width
    8.2 mm
  • Screw thread
    M4
  • Connection in acc. with standard
    CSA
  • Max. AWG conductor cross section, flexible
    8
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 5.0
    27141100
  • ETIM 4.0
    EC000902
  • ETIM 7.0
    EC000902
  • UNSPSC 12.01
    39121410
  • Number of connections
    2
  • Area of application
    Railway industry
  • Rated surge voltage
    6 kV
  • Maximum power dissipation for nominal condition
    1.31 W
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test duration per axis
    5 h
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Height NS 35/7,5
    47.5 mm
  • Connection method
    Screw connection
  • Tightening torque, min
    1.5 Nm
  • Conductor cross section AWG max.
    8
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • 2 conductors with same cross section, stranded min.
    0.2 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.0
    27141100
  • ECLASS 5.1
    27141100
  • ETIM 2.0
    EC000902
  • UNSPSC 11
    39121410
  • UNSPSC 19.0
    39121410
  • Number of levels
    1
  • Insulating material
    PA
  • Degree of pollution
    3
  • Insulating material group
    I
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Bending test rotation speed
    10 (+/- 2) rpm
  • Result of tight fit on support
    Test passed
  • Result of temperature-rise test
    Test passed
  • Short-time current
    0.3 kA
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Acceleration
    30g
  • Shock form
    Semi-sinusoidal
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Length
    57.8 mm
  • Tightening torque max
    1.8 Nm
  • Conductor cross section solid min.
    0.2 mm²
  • Min. AWG conductor cross section, flexible
    24
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    4 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27141100
  • ECLASS 9.0
    27141126
  • UNSPSC 7.0901
    39121410
  • UNSPSC 21.0
    39121410
  • Note
    Current and voltage are determined by the plug used.
  • Nominal cross section
    6 mm²
  • Flammability rating according to UL 94
    V0
  • Overvoltage category
    III
  • Nominal voltage UN
    500 V
  • Finger protection
    guaranteed
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Tight fit on carrier
    NS 32/NS 35
  • Short circuit stability result
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock duration
    18 ms
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Stripping length
    10 mm
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section flexible max.
    10 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, stranded max.
    2.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 10.0.1
    27141126
  • ECLASS 7.0
    27141126
  • ETIM 6.0
    EC000902
  • UNSPSC 13.2
    39121410
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141126
  • ECLASS 6.0
    27141100
  • ETIM 3.0
    EC000902
  • UNSPSC 6.01
    30211811
  • UNSPSC 18.0
    39121410
  • UNSPSC 20.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo