3035700 Phoenix Contact Terminal Blocks

Phoenix Contact 3035700 Test disconnect terminal block, nom. voltage: 500 V, nominal current: 30 A, connection method: Spring-cage connection, number of connections: 2, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 8.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3035700

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 48

Nov 27, 2024

Test disconnect terminal block, nom. voltage: 500 V, nominal current: 30 A, connection method: Spring-cage connection, number of connections: 2, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 8.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3035700 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of connections
    2
  • Flammability rating according to UL 94
    V0
  • Maximum load current
    30 A (with 10 mm² conductor cross section)
  • Back of the hand protection
    guaranteed
  • Setpoint
    5 N
  • Color
    gray
  • Overvoltage category
    III
  • Nominal current IN
    30 A
  • Result of surge voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • ETIM 4.0
    EC000902
  • ETIM 7.0
    EC000902
  • UNSPSC 19.0
    39121410
  • Number of levels
    1
  • Insulating material
    PA
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of flexion and pull-out test
    Test passed
  • Degree of pollution
    3
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Tensile test result
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Maximum power dissipation for nominal condition
    1.31 W
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of aging test
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test duration per axis
    5 h
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Height NS 35/15
    57.1 mm
  • UNSPSC 7.0901
    39121410
  • Bending test turns
    135
  • Short circuit stability result
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Potentials
    1
  • Shock duration
    18 ms
  • Insulating material group
    I
  • Nominal voltage UN
    500 V
  • Shock test result
    Test passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    8.2 mm
  • Connection method
    Spring-cage connection
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ETIM 3.0
    EC000902
  • Nominal cross section
    6 mm²
  • Rated surge voltage
    6 kV
  • Open side panel
    Yes
  • Finger protection
    guaranteed
  • Tight fit on carrier
    NS 35
  • Short-time current
    1.25 kA
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Acceleration
    30g
  • Shock form
    Half-sine
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Stripping length
    12 mm
  • Conductor cross section flexible max.
    6 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • UNSPSC 6.01
    30211811
  • UNSPSC 18.0
    39121410
  • UNSPSC 21.0
    39121410
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • Conductor cross section AWG max.
    8
  • ECLASS 7.0
    27141126
  • ETIM 6.0
    EC000902
  • UNSPSC 12.01
    39121410
  • UNSPSC 13.2
    39121410
  • ASD level
    6.12 (m/s2)2/Hz
  • Conductor cross section solid min.
    0.2 mm²
  • Result of temperature-rise test
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Result of voltage-drop test
    Test passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Oscillation, broadband noise test result
    Test passed
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Conductor cross section short circuit testing
    4 mm²
  • Height NS 35/7,5
    49.6 mm
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Min. AWG conductor cross section, flexible
    24
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141126
  • ETIM 2.0
    EC000902
  • UNSPSC 11
    39121410
  • UNSPSC 20.0
    39121410
  • ECLASS 4.0
    27141100
  • ECLASS 6.0
    27141100
  • ECLASS 9.0
    27141126
  • Result of thermal test
    Test passed
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Length
    100.8 mm
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.1
    27141100
  • Result of tight fit on support
    Test passed
  • Number of shocks per direction
    3
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Connection in acc. with standard
    CUL
  • Max. AWG conductor cross section, flexible
    10
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • Internal cylindrical gage
    A4
  • ECLASS 5.0
    27141100
  • ECLASS 10.0.1
    27141126

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$19.94

Stock:

48

Select Qty:

$19.94

$19.94 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo