2320898 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2320898 Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 1-phase, output: 24 V DC / 20 A
Phoenix Contact

Part#:2320898

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 17

Apr 26, 2024

About the product: Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 1-phase, output: 24 V DC / 20 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2320898 Phoenix Contact price in the box on the right side or send a quick quote.

2320898 Product Details

  • Installation distance right/left
    5 mm / 5 mm
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Dielectric strength maximum
    300 V AC
  • Input fuse
    12 A (slow-blow, internal)
  • Nominal output voltage
    24 V DC ±1 %
  • Selective Fuse Breaking (ISFB)
    120 A (12 ms)
  • Residual ripple
    < 30 mVPP (with nominal values)
  • Protection against overvoltage at the output (OVP)
    < 32 V DC
  • Height
    130 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Max. permissible relative humidity (operation)
    100 % (at 25 °C, non-condensing)
  • Depth with alternative assembly
    93 mm
  • Discharge in air
    15 kV (Test Level 4)
  • Width
    90 mm
  • Width with alternative assembly
    122 mm
  • Recommended breaker for input protection
    10 A ... 16 A (AC: Characteristics B, C, D, K)
  • Electromagnetic HF field
    EN 61000-4-3
  • Degree of pollution
    2
  • AC frequency range
    45 Hz ... 65 Hz
  • Mains buffering time
    typ. 32 ms (120 V AC)
  • Setting range of the output voltage (USet)
    18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Installation height
    6000 m
  • Frequency range DC
    0 Hz
  • Nominal power consumption
    569 VA
  • Type of protection
    Transient surge protection
  • POWER BOOST (IBoost)
    26 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC )
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Maximum power dissipation in no-load condition
    8 W
  • Efficiency
    > 93 % (for 230 V AC and nominal values)
  • Net weight
    1.7 kg
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Conductor cross section AWG max.
    10
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Stripping length
    7 mm
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Rail applications
    EN 50121-4
  • UL approvals
    UL/C-UL listed UL 508
  • DeviceNet approval
    DeviceNet™ Power Supply Conformance Tested
  • Fast transients (burst)
    EN 61000-4-4
  • Degree of protection
    IP20
  • Current consumption
    5.1 A (120 V AC)
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Depth
    125 mm
  • Height with alternative assembly
    130 mm
  • Ambient temperature (operation)
    -40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Input voltage range
    85 V AC ... 264 V AC
  • Inrush current
    < 20 A
  • Discharge current to PE
    < 3.5 mA
  • Protective circuit/component
    Varistor, gas-filled surge arrester
  • Nominal output current (IN)
    20 A (-25 °C ... 60 °C, UOUT = 24 V DC)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Connection in series
    yes
  • Power loss nominal load max.
    40 W
  • Insulation voltage input/output
    4 kV AC (type test)
  • Insulation voltage output / PE
    500 V DC (routine test)
  • Protection class
    I
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section solid max.
    6 mm²
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Standard - Equipment safety
    BG (design tested)
  • Mains variation/undervoltage
    SEMI F47-0706 Compliance Certificate
  • Shipbuilding approval
    DNV GL (EMC B, only with upstream filter)
  • Input
    2 kV (Test Level 3 - symmetrical)
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 4.0
    27040700
  • ECLASS 4.1
    27040700
  • ECLASS 6.0
    27049000
  • UNSPSC 11
    39121004
  • UNSPSC 13.2
    39121004
  • Feedback voltage resistance
    max. 35 V DC
  • Output power
    480 W
  • Typical response time
    < 0.6 s
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG min.
    18
  • HART FSK Physical Layer Test Specification Compliance
    Output voltage UOut compliant
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Contact discharge
    8 kV (Test Level 4)
  • Frequency range
    0.15 MHz ... 80 MHz
  • Surge voltage load (surge)
    EN 61000-4-5
  • Criterion A
    Normal operating behavior within the specified limits.
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.0
    27049000
  • ETIM 6.0
    EC002540
  • ETIM 7.0
    EC002540
  • UNSPSC 7.0901
    39121004
  • UNSPSC 19.0
    39121004
  • UNSPSC 21.0
    39121004
  • MTBF (IEC 61709, SN 29500)
    > 900000 h (25 °C)
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • Connection method
    Screw connection
  • Conductor cross section flexible max.
    4 mm²
  • Screw thread
    M4
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Explosive atmosphere
    EN 60079-15 (Zone 2)
  • SIQ
    BG (type approved)
  • Electrostatic discharge
    EN 61000-4-2
  • Test field strength
    10 V/m (Test Level 3)
  • Conducted interference
    EN 61000-4-6
  • Voltage
    10 V (Test Level 3)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27040701
  • ECLASS 5.1
    27049000
  • UNSPSC 6.01
    30211502
  • ECLASS 9.0
    27040701
  • UNSPSC 12.01
    39121004
  • UNSPSC 20.0
    39121004
  • Comments
    Criterion A
  • Output
    1 kV (Test Level 2 - symmetrical)
  • I/O/S
    asymmetrical
  • ECLASS 10.0.1
    27040701
  • ETIM 4.0
    EC000599
  • ECLASS 7.0
    27049002
  • UNSPSC 18.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 3 days!

1-year warranty

$531.56

2320898

Stock:

17

Select Qty:

$531.56

$531.56 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo