Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2320115 Phoenix Contact DC/DC Converters

Phoenix Contact 2320115 Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 24 V DC, output: 12 V DC/8 A
Phoenix Contact

Part#:2320115

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 343

Nov 21, 2024

Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 24 V DC, output: 12 V DC/8 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2320115 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height
    130 mm
  • Height with alternative assembly
    130 mm
  • Installation distance right/left
    0 mm / 0 mm (≤ 70 °C)
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C derating, 2.5 %/K, startup at -40°C type-tested)
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Nominal input voltage range
    24 V DC
  • Extended input voltage range in operation
    14 V DC ... 18 V DC (Consider derating during operation)
  • Inrush current
    < 15 A (typical)
  • Setting range of the output voltage (USet)
    5 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
  • POWER BOOST (IBoost)
    10 A (-25 °C ... 40 °C permanent, UOUT = 12 V DC )
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Connection in series
    yes
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Width
    32 mm
  • Width with alternative assembly
    122 mm
  • Installation distance top/bottom
    50 mm / 50 mm (≤ 70 °C)
  • Degree of protection
    IP20
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of pollution
    2
  • Current consumption
    6 A (24 V, IBOOST)
  • Mains buffering time
    > 10 ms (24 V DC)
  • Type of protection
    Transient surge protection
  • Nominal output current (IN)
    8 A (-25 °C ... 60 °C)
  • Selective Fuse Breaking (ISFB)
    48 A (12 ms)
  • Feedback voltage resistance
    25 V DC
  • Max. capacitive load
    unlimited
  • Peak switching voltages nominal load
    < 10 mVPP (20 MHz)
  • Power loss nominal load max.
    10.5 W
  • Depth
    125 mm
  • Depth with alternative assembly
    35 mm
  • Installation distance top/bottom (active)
    50 mm / 50 mm (≤ 70 °C)
  • Installation distance right/left (active)
    15 mm / 15 mm (≤ 70 °C)
  • Ambient temperature (start-up type tested)
    -40 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Input voltage range
    18 V DC ... 32 V DC
  • Input fuse
    15 A (internal (device protection))
  • Protective circuit/component
    Varistor
  • Nominal output voltage
    12 V DC ±1 %
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Protection against overvoltage at the output (OVP)
    < 25 V DC
  • Active current limitation
    15 A
  • Residual ripple
    < 20 mVPP
  • Net weight
    0.7 kg
  • Insulation voltage input/output
    1.5 kV (type test)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible max.
    2.5 mm²
  • Conductor cross section AWG max.
    12
  • Screw thread
    M3
  • EMC requirements for noise immunity
    EN 61000-6-1
  • UL approvals
    UL/C-UL listed UL 508
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Comments
    Criterion A
  • Surge voltage load (surge)
    EN 61000-4-5
  • Voltage
    10 V (Test Level 3)
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 11.0
    27210901
  • ECLASS 5.0
    27210900
  • ETIM 4.0
    EC002542
  • UNSPSC 11
    39121004
  • UNSPSC 19.0
    39121041
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Electrostatic discharge
    EN 61000-4-2
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    0.15 MHz ... 80 MHz
  • Input
    1 kV (Test Level 2 - symmetrical)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27210900
  • ETIM 7.0
    EC002046
  • UNSPSC 7.0901
    39121004
  • UNSPSC 18.0
    39121041
  • UNSPSC 21.0
    39121041
  • Maximum power dissipation in no-load condition
    2 W
  • Efficiency
    > 90 %
  • Protection class
    III
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Conductor cross section flexible min.
    0.2 mm²
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - Electrical safety
    EN 60950-1/VDE 0805 (SELV)
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Shipbuilding approval
    DNV GL (EMC B)
  • Discharge in air
    15 kV (Test Level 4)
  • Test field strength
    10 V/m
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 10.0.1
    27210901
  • ECLASS 6.0
    27210900
  • ECLASS 7.0
    27210901
  • ETIM 6.0
    EC002046
  • UNSPSC 13.2
    39121041
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Connection method
    Pluggable screw connection
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG min.
    24
  • Stripping length
    7 mm
  • Standard – Safety extra-low voltage
    EN 60950-1 (SELV)
  • Rail applications
    EN 50121-4
  • Contact discharge
    8 kV (Test Level 4)
  • Fast transients (burst)
    EN 61000-4-4
  • I/O/S
    asymmetrical
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 4.0
    27210900
  • ECLASS 5.1
    27210900
  • ECLASS 9.0
    27210901
  • UNSPSC 6.01
    30211502
  • UNSPSC 12.01
    39121004
  • UNSPSC 20.0
    39121041

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$391.56

Stock:

343

Select Qty:

$391.56

$391.56 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo