Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

1039829 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 1039829 TRIO POWER primary-switched power supply in IP67 die-cast housing, input: 3-phase, output: 24 V DC / 20 A
Phoenix Contact

Part#:1039829

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: TRIO POWER primary-switched power supply in IP67 die-cast housing, input: 3-phase, output: 24 V DC / 20 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1039829 Phoenix Contact price in the box on the right side or send a quick quote.

1039829 Product Details

  • Installation distance right/left
    20 mm / 20 mm
  • Ambient temperature (operation)
    -25 °C ... 85 °C (Derating > 60 °C (3 AC): 2,5 %/K / > 50 °C (2 AC): 2,5 %/K)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Current consumption
    3x 1.2 A (400 V AC)
  • Mains buffering time
    typ. 10 ms (400 V AC)
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Typical response time
    < 1 s
  • Protection class
    I
  • Coding
    A-coded
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Electrostatic discharge
    EN 61000-4-2
  • Depth
    120 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Installation height
    ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
  • Discharge current to PE
    < 3.5 mA
  • Input fuse
    3.15 A (internal (device protection), slow-blow)
  • Protective circuit/component
    Varistor
  • Protection against overvoltage at the output (OVP)
    ≤ 30 V DC
  • Net weight
    3.7 kg
  • MTBF (IEC 61709, SN 29500)
    > 1500000 h (25 °C)
  • Type of locking
    SPEEDCON M12
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Conducted noise emission
    EN 55016
  • Discharge in air
    8 kV (Test Level 4)
  • Input
    2 kV (Test Level 3 - symmetrical)
  • Voltage
    400 V AC
  • Voltage dip
    0 %
  • REACh SVHC
    Lead 7439-92-1
  • ETIM 6.0
    EC002540
  • Installation distance top/bottom
    50 mm / 100 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Degree of pollution
    4
  • Input voltage range
    3x 400 V AC ... 500 V AC -20 % ....+15 %
  • Nominal power consumption
    39 W
  • Nominal output voltage
    24 V DC ±1 %
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Output power
    480 W
  • Insulation voltage input/output
    4 kV AC (type test)
  • Connection method
    Circular connector
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Flicker
    EN 61000-3-3
  • Electromagnetic HF field
    EN 61000-4-3
  • Comments
    Criterion A
  • Conducted interference
    EN 61000-4-6
  • Additional text
    Test Level 2
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • Height
    304 mm
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Nominal input voltage range
    3x 400 V AC ... 500 V AC
  • Inrush current
    typ. 22 A (at 25 °C)
  • Type of protection
    Transient surge protection
  • Nominal output current (IN)
    20 A
  • Maximum power dissipation in no-load condition
    < 2 W (400 V AC)
  • Efficiency
    93 % (400 V AC)
  • Standard – Safety extra-low voltage
    EN 60204-1 (PELV)
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Noise emission
    EN 55016
  • Frequency range
    0.15 MHz ... 80 MHz
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Frequency
    50 Hz
  • ECLASS 9.0
    27040701
  • Width
    151 mm
  • Degree of protection
    IP67
  • Climatic class
    3K3 (in acc. with EN 60721)
  • AC frequency range
    50 Hz ... 60 Hz
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristics B, C, D, K)
  • Dynamic Boost (IDyn.Boost)
    30 A (5 s)
  • Residual ripple
    ≤ 20 mVPP
  • Power loss nominal load max.
    < 44 W (400 V AC)
  • Assembly instructions
    Alignable: 20 mm horizontally, 50 mm vertically above, 100 mm vertically below
  • Number of positions
    5
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Contact discharge
    6 kV (Test Level 4)
  • Test field strength
    10 V/m (Test Level 3)
  • Voltage dips
    EN 61000-4-11
  • Number of periods
    1 period
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27040701
  • Fast transients (burst)
    EN 61000-4-4
  • Signal
    1 kV (Test Level 1 - asymmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 11.0
    27040701
  • ETIM 7.0
    EC002540

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

1039829

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo