2700357 Phoenix Contact Electrical Safety Devices
Part#:2700357
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Coupling relay for SIL 2 high- and low-demand applications, couples digital output signals to the I/O, 1 enabling current path, 1 confirmation current path, 1 digital signal output, safe state off applications, test pulse filter, fixed screw terminal bloc
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2700357 Phoenix Contact price in the box on the right side or send a quick quote.
2700357 Product Details
- Width 6.8 mm
- Ambient temperature (operation) -40 °C ... 65 °C (observe derating)
- Input current range "0" signal 0 mA ... 2 mA (for safe Off)
- Inrush current at UD typ. 2.5 A (Δt < 20 µs at UD)
- Number of outputs 1 (non-safety-related)
- Switching capacity min. 20 mW
- Mechanical service life 10x 106 cycles
- Current max. 100 mA
- Recovery time 500 ms
- Nominal operating mode 100% operating factor
- Housing material PBT
- Housing color yellow
- pluggable no
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Torque 0.5 Nm ... 0.6 Nm
- Shock 15g
- Conformance CE-compliant
- ECLASS 4.0 40020600
- ECLASS 5.1 27371900
- ETIM 6.0 EC001449
- Height 93.1 mm
- Maximum altitude ≤ 2000 m (Above sea level)
- Output description PNP
- Switching voltage min. 20.4 V DC
- Sq. Total current 36 A2 (observe derating)
- Designation Air clearances and creepage distances between the power circuits
- Voltage approx. 22 V DC (UD - 2 V)
- Assembly instructions See derating curve
- Connection method Screw connection
- Stop category 0
- Safety Integrity Level (SIL) 2
- Overvoltage category III
- Environmental simulation test ISA-S71.04 (G3)
- ECLASS 4.1 40020600
- ECLASS 5.0 27371900
- Depth 102.5 mm
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Input voltage range "0" signal 0 V DC ... 5 V DC (for safe Off)
- Filter time max. 2 ms (at A1-A2; test pulse width)
- Output name Confirmation current path
- Protective circuit Serial protection against polarity reversal Suppressor diode 33 V (A1/A2), 38 V (21/A2)
- Contact material AgCuNi, + Au
- Maximum inrush current 500 mA (Δt = 1 ms at Us)
- Net weight 63.593 g
- Mounting type DIN rail mounting
- Degree of protection IP20
- Min. degree of protection of inst. location IP54
- Indication 1 x red LED
- Stripping length 12 mm
- Rated surge voltage/insulation Safe isolation, 6 kV reinforced insulation from control circuit, start circuit, confirmation current path, signal output to the enabling current path; 4 kV/basic insulation between all current paths and housing
- ATEX II 3 G Ex nA nC IIC T4 Gc
- IECEx Ex nA nC IIC T4 Gc
- REACh SVHC Lead 7439-92-1
- ECLASS 6.0 27371800
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Rated control supply current IS typ. 45 mA
- Power consumption at US typ. 1.08 W
- Input current at UD 6 mA (at 21-A2 for UD; depending on load + 100 mA at M1 and 22)
- Contact type 1 confirmation current path
- Limiting continuous current 100 mA
- Switching capacity according to IEC 60947-5-1 4 A (24 V (DC13))
- Output fuse 150 mA fast blow
- Typical pickup time at US < 100 ms (with Us when controlled via A1)
- Typical release time at US < 35 ms (when controlled via A1)
- Operating voltage display 1 x yellow LED
- Status display 2 x green LEDs
- Conductor cross-section AWG 24 ... 12
- Standards/regulations DIN EN 50178, EN 60079-15
- Degree of pollution 2
- UL, USA/Canada cULus
- ECLASS 10.0.1 27371819
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 7.0 27371819
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Rated control circuit supply voltage US 24 V DC -15 % / +10 % (A1/A2)
- Inrush current min. 1 mA
- Diagnostic supply voltage UD 24 V DC -15 % / +10 % (21/A2)
- Switching frequency max. 1 Hz
- Short-circuit protection no
- Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Mounting position vertical, horizontal, with front of module upward
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Screw thread M3
- Rated insulation voltage 250 V AC
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- GL C, EMC2
- ECLASS 11.0 27371819
- ECLASS 9.0 27371819
- ETIM 7.0 EC001449
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2700357
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨