3010013 Phoenix Contact Terminal Blocks
Part#:3010013
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
High-current terminal block, Screws with hexagonal socket, nom. voltage: 1000 V, nominal current: 232 A, connection method: Screw connection, number of connections: 2, cross section: 25 mm² - 95 mm², AWG: 4 - 3/0, width: 25 mm, height: 90 mm, color: gray,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3010013 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Overvoltage category III
- Conductor cross section short circuit testing 95 mm²
- Acceleration 30g
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Static insulating material application in cold -60 °C
- Width 25 mm
- Screw thread M8
- Stripping length 33 mm
- Conductor cross section AWG min. 4
- Min. AWG conductor cross section, flexible 2
- Conductor cross section flexible, with ferrule with plastic sleeve min. 35 mm²
- 2 conductors with same cross section, solid min. 25 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 16 mm²
- ECLASS 11.0 27141120
- ECLASS 7.0 27141120
- Color gray
- Degree of pollution 3
- Power frequency withstand voltage setpoint 2.2 kV
- Bending test conductor cross section/weight 25 mm² / 4.5 kg
- Conductor cross section tensile test 95 mm²
- Requirements, voltage drop U1 ≤ 3,2 mVU2 ≤ 1,5 x U1dT ≤ 45 K
- ETIM 4.0 EC000897
- UNSPSC 7.0901 39121410
- UNSPSC 20.0 39121410
- UNSPSC 21.0 39121410
- Surface flammability NFPA 130 (ASTM E 162) passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Height NS 35/15 97.5 mm
- Tightening torque, min 15 Nm
- Conductor cross section flexible min. 35 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 35 mm²
- Cross section with insertion bridge, solid max. 95 mm²
- 2 conductors with same cross section, stranded max. 35 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 35 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- Rated surge voltage 8 kV
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Bending test turns 135
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Shock form Half-sine
- ECLASS 4.1 27141100
- ECLASS 5.0 27141100
- ETIM 3.0 EC000897
- ETIM 7.0 EC000897
- UNSPSC 19.0 39121410
- Conductor cross section flexible max. 95 mm²
- Conductor cross section AWG max. 3/0
- Cross section with insertion bridge, stranded max. 70 mm²
- 2 conductors with same cross section, stranded min. 25 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 125°C)
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 4.0 27141100
- ECLASS 5.1 27141100
- ECLASS 9.0 27141120
- UNSPSC 6.01 30211811
- UNSPSC 18.0 39121410
- UNSPSC 11 39121410
- Finger protection guaranteed
- Tight fit on carrier NS 32/NS 35
- Result of temperature-rise test Test passed
- Result of thermal test Test passed
- Test spectrum Service life test category 2, bogie-mounted
- Flammability rating according to UL 94 V0
- Maximum load current 232 A
- Test duration per axis 5 h
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Height NS 32 95 mm
- Connection method Screw connection
- Conductor cross section solid min. 25 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 95 mm²
- 2 conductors with same cross section, solid max. 35 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 10.0.1 27141120
- ECLASS 6.0 27141100
- ETIM 2.0 EC000897
- ETIM 6.0 EC000897
- UNSPSC 13.2 39121410
- UNSPSC 12.01 39121410
- Insulating material PA
- Insulating material group I
- Result of power-frequency withstand voltage test Test passed
- Tractive force setpoint 351 N
- Result of voltage-drop test Test passed
- Short circuit stability result Test passed
- ASD level 6.12 (m/s2)2/Hz
- Number of shocks per direction 3
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Length 83 mm
- Connection in acc. with standard CSA
- Conductor cross section solid max. 95 mm²
- Max. AWG conductor cross section, flexible 3/0
- Conductor cross section flexible, with ferrule with plastic sleeve max. 95 mm²
- Result of flexion and pull-out test Test passed
- Result of tight fit on support Test passed
- Short-time current 11.4 kA
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Shock duration 18 ms
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height 90 mm
- Tightening torque max 20 Nm
- Maximum power dissipation for nominal condition 7.54 W
- Nominal voltage UN 1000 V
- Number of levels 1
- Nominal current IN 232 A
- Bending test rotation speed 10 rpm
- Open side panel No
- Shock protection test specification IEC 60529:2013-08
- Tensile test result Test passed
- Potentials 1
- Nominal cross section 95 mm²
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- Note Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
- Back of the hand protection guaranteed
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Number of connections 2
- Terminal block mounting 15 Nm ... 20 Nm
- Result of surge voltage test Test passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨