Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

X67BCD321.L12 B&R Electronic Components

B&R X67BCD321.L12 X67 bus controller, 1 EtherNet/IP interface, X2X Link power supply 15 W, 16 digital channels configurable as inputs or outputs, 24 VDC, 0.5 A, configurable input filter, 2 event counters 50 kHz, M12 connectors, high-density module
B&R

Part#:X67BCD321.L12

Manufacturer:B&R

Product Lifecycle:Active

Get a quick Quote!

X67 bus controller, 1 EtherNet/IP interface, X2X Link power supply 15 W, 16 digital channels configurable as inputs or outputs, 24 VDC, 0.5 A, configurable input filter, 2 event counters 50 kHz, M12 connectors, high-density module

Check out the X67BCD321.L12 B&R price in the box on the right side or send a quick quote.

Product Details

  • Weight355 g
  • Torque for connections M12
    Max. 0.6 Nm
  • Dimensions Depth
    42 mm
  • Installation elevation above sea level 0 to 2000 m
    No limitation
  • Temperature Transport
    -40 to 85°C
  • Dimensions Width
    53 mm
  • Dimensions Height
    155 mm
  • Torque for connections M8
    Max. 0.4 Nm
  • Temperature Storage
    -40 to 85°C
  • Switching delay 1 → 0
    <400 µs
  • Installation elevation above sea level >2000 m
    Reduction of ambient temperature by 0.5°C per 100 m
  • Mounting orientation Any
    Yes
  • Temperature Operation
    -25 to 60°C
  • Input filter Software
    Default 0 ms, configurable between 0 and 25 ms in 0.2 ms intervals
  • Switching delay 0 → 1
    <400 µs
  • Temperature Derating
    -
  • Switching frequency Resistive load
    Max. 100 Hz
  • Power consumption Sensor/Actuator power supply
    Max. 12 W
  • Switching frequency Inductive load
    See section "Switching inductive loads".
  • Input filter Hardware
    ≤10 μs (channels 1 to 4) / ≤70 µs (channels 5 to 8)
  • Counter frequency Internal
    48 MHz, 3 MHz, 187.5 kHz
  • Min. cycle time X2X Link
    500 μs
  • Transfer Auto-MDI/MDIX
    Yes
  • Switching threshold High
    >15 VDC
  • Switching threshold Low
    <5 VDC
  • Transfer Half-duplex
    Yes
  • Min. cycle time Fieldbus
    1 ms
  • Transfer Autonegotiation
    Yes
  • Certifications UL
    cULus E115267; Industrial control equipment
  • B&R ID code Bus controller
    0xACF7
  • Certifications ATEX
    Zone 2, II 3G Ex nA IIA T5 Gc; IP67, Ta = 0 - Max. 60°C; TÜV 05 ATEX 7201X
  • Transfer Full-duplex
    Yes
  • Diagnostics Outputs
    Yes, using LED status indicator and software
  • Braking voltage when switching off inductive loads
    50 VDC
  • Certifications KC
    Yes
  • Certifications EAC
    Yes
  • Power consumption Fieldbus
    2.5 W
  • Residual voltage
    <0.3 V at 0.5 A nominal current
  • Certifications UKCA
    Yes
  • Transfer Physical layer
    10BASE-T/100BASE-TX
  • Nominal output current
    0.5 A
  • Certifications HazLoc
    cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
  • Power consumption X2X Link power supply
    20.5 W at maximum power output for connected I/O modules
  • Certifications CE
    Yes
  • Degree of protection per EN 60529
    IP67
  • Connection type I/O power supply
    M8, 4-pin
  • Power consumption Internal I/O
    3.3 W
  • Diagnostics I/O power supply
    Yes, using LED status indicator and software
  • B&R ID code Internal I/O module
    0xB1E7
  • Switching on after overload shutdown
    Approx. 10 ms (depends on the module temperature)
  • Connection type X2X Link
    M12, B-coded
  • Length of pause between pulses
    ≥100 µs
  • Electrical isolation
    Channel isolated from bus; EtherNet/IP not isolated from bus and channel not isolated from channel
  • Input current at 24 VDC
    Typ. 4 mA
  • Pulse length
    ≥20 µs
  • Diagnostic status
    Output monitoring with 10 ms delay
  • Leakage current when the output is switched off
    5 µA
  • Switching voltage
    I/O power supply minus residual voltage
  • Counter size
    16-bit
  • Output protection
    Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply
  • Output circuit
    Source
  • Input circuit
    Sink
  • Input characteristics per EN 61131-2
    Type 1
  • Counter 2
    Input 3
  • Additional functions
    50 kHz event counting, gate measurement
  • Bus controller
    EtherNet/IP Adapter (slave)
  • Fieldbus
    EtherNet/IP Adapter (slave)
  • Variant
    Internal 3x switch, male M12 circular connector, 2 female connectors on the module
  • Connection type Inputs/Outputs
    8x M12, A-coded
  • Connection type Fieldbus
    M12, D-coded
  • Peak short-circuit current
    <12 A
  • Total nominal current
    8 A
  • Supported inputs
    Input 2 or input 4
  • Counter frequency
    Max. 50 kHz
  • Evaluation
    Each negative edge, cyclic counter
  • Signal form
    Square wave pulse
  • Counter 1
    Input 1
  • Input frequency
    Max. 50 kHz
  • Quantity
    2
  • Input resistance
    Typ. 6 kΩ
  • Short-circuit proof
    Yes
  • Input voltage
    18 to 30 VDC
  • Summation current
    Max. 0.5 A
  • Voltage drop for short-circuit protection at 0.5 A
    Max. 2 VDC
  • Voltage
    I/O power supply minus voltage drop for short-circuit protection
  • Synchronization between bus systems possible
    No
  • Integrated protection
    Reverse polarity protection
  • Voltage range
    18 to 30 VDC
  • Transfer rate
    10/100 Mbit/s
  • Line length
    Max. 100 m between 2 stations (segment length)
  • Status indicators
    I/O function per channel, supply voltage, bus function
  • Nominal voltage
    24 VDC
  • Power output
    15 W X2X Link power supply for I/O modules
  • Sensor/Actuator power supply
    0.5 A summation current
  • Insulation voltage between channel and bus
    500 Veff
  • Inputs/Outputs
    16 digital channels, configurable as inputs or outputs using Automation Studio or data point, inputs with additional functions

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo