X67BC8513.L12 B&R Electronic Components

B&R X67BC8513.L12 X67 bus controller, 1 POWERLINK interface, X2X Link power supply 15 W, 12 digital channels configurable as inputs or outputs, 24 VDC, 0.5 A, configurable input filter, 1 event counters 50 kHz, 1 analog input 0 to 20 mA, 12-bit, M12 connectors, high-densit
B&R

Part#:X67BC8513.L12

Manufacturer:B&R

Product Lifecycle:Active

Get a quick Quote!

X67 bus controller, 1 POWERLINK interface, X2X Link power supply 15 W, 12 digital channels configurable as inputs or outputs, 24 VDC, 0.5 A, configurable input filter, 1 event counters 50 kHz, 1 analog input 0 to 20 mA, 12-bit, M12 connectors, high-densit

Check out the X67BC8513.L12 B&R price in the box on the right side or send a quick quote.

Product Details

  • Weight360 g
  • Dimensions Height
    155 mm
  • Torque for connections M8
    Max. 0.4 Nm
  • Dimensions Depth
    42 mm
  • Torque for connections M12
    Max. 0.6 Nm
  • Temperature Transport
    -40 to 85°C
  • Dimensions Width
    53 mm
  • Temperature Storage
    -40 to 85°C
  • Temperature Operation
    -25 to 60°C
  • Temperature Derating
    -
  • Installation elevation above sea level >2000 m
    Reduction of ambient temperature by 0.5°C per 100 m
  • Switching delay 0 → 1
    <400 µs
  • Switching frequency Inductive load
    See section "Switching inductive loads".
  • Installation elevation above sea level 0 to 2000 m
    No limitation
  • Switching frequency Resistive load
    Max. 100 Hz
  • Mounting orientation Any
    Yes
  • Input filter Cutoff frequency
    1 kHz
  • Input filter Slope
    40 dB
  • Switching delay 1 → 0
    <400 µs
  • Output of digital value during overload Overshoot
    0x7FFF
  • Common-mode rejection DC
    >50 dB
  • Max. error Gain
    0.1%
  • Max. error Offset
    0.05%
  • Common-mode rejection 50 Hz
    >50 dB
  • Output of digital value during overload Undershoot
    0x0000
  • Switching threshold Low
    <5 VDC
  • Switching threshold High
    >15 VDC
  • Counter frequency Internal
    48 MHz, 3 MHz, 187.5 kHz
  • Input filter Software
    Default 0 ms, configurable between 0 and 25 ms in 0.2 ms intervals
  • Output format Current
    0x0000 - 0x7FFF / 1 LSB = 0x0008 = 4.883 μA
  • Input filter Hardware
    ≤10 μs (channels 1 to 4) / ≤70 µs (channels 5 to 12)
  • Transfer Auto-MDI/MDIX
    Yes
  • Transfer Autonegotiation
    Yes
  • Min. cycle time Fieldbus
    200 μs
  • Power consumption Sensor/Actuator power supply
    Max. 12 W
  • Transfer Half-duplex
    Yes
  • Transfer Full-duplex
    No
  • Min. cycle time X2X Link
    200 μs
  • Certifications EAC
    Yes
  • Certifications KC
    Yes
  • Certifications ATEX
    Zone 2, II 3G Ex nA IIA T5 Gc; IP67, Ta = 0 - Max. 60°C; TÜV 05 ATEX 7201X
  • Certifications HazLoc
    cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
  • Transfer Physical layer
    100BASE-TX
  • Certifications UL
    cULus E115267; Industrial control equipment
  • Certifications CE
    Yes
  • Power consumption X2X Link power supply
    17.25 W at maximum power output for connected I/O modules
  • Power consumption Fieldbus
    2.5 W
  • Certifications UKCA
    Yes
  • Power consumption Internal I/O
    0.6 W
  • Connection type I/O power supply
    M8, 4-pin
  • Connection type Fieldbus
    M12, D-coded
  • Connection type X2X Link
    M12, B-coded
  • Connection type Inputs/Outputs
    8x M12, A-coded
  • Diagnostics I/O power supply
    Yes, using LED status indicator and software
  • B&R ID code Bus controller
    0xB3AC
  • Diagnostics Outputs
    Yes, using LED status indicator and software
  • B&R ID code Internal I/O module
    0xB3CD
  • Degree of protection per EN 60529
    IP67
  • Braking voltage when switching off inductive loads
    50 VDC
  • Electrical isolation
    Bus isolated from POWERLINK and channel; Channel not isolated from channel
  • Type
    Type 2
  • RDS(on)
    150 mΩ
  • Bus controller
    POWERLINK (V1/V2) controlled node
  • Residual voltage
    <0.3 V at 0.5 A nominal current
  • Peak short-circuit current
    <12 A
  • Leakage current when the output is switched off
    5 µA
  • Switching on after overload shutdown
    Approx. 10 ms (depends on the module temperature)
  • Diagnostic status
    Output monitoring with 10 ms delay
  • Total nominal current
    8 A
  • Output protection
    Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply
  • Output circuit
    Source
  • Nominal output current
    0.5 A
  • Voltage drop at 20 mA
    Typ. 4.5 V
  • Fieldbus
    POWERLINK (V1/V2) controlled node
  • Switching voltage
    I/O power supply minus residual voltage
  • Insulation voltage between input and bus
    500 Veff
  • Nonlinearity
    <0.1%
  • Inputs/Outputs
    12 digital channels (configurable as inputs or outputs using the software, inputs with additional functions), 1 analog channel
  • Power output
    15 W X2X Link power supply for I/O modules
  • Max. offset drift
    0.02 %/°C
  • Status indicators
    I/O function per channel, supply voltage, bus function
  • Sensor/Actuator power supply
    0.5 A summation current
  • Common-mode range
    ±2 V
  • Max. gain drift
    0.013 %/°C
  • Crosstalk between channels
    >70 dB
  • Insulation voltage between channel and bus
    500 Veff
  • Conversion procedure
    Successive approximation
  • Load
    <300 Ω
  • Permissible input signal
    Max. ±30 mA
  • Output format
    INT
  • Input protection
    Protection against wiring with supply voltage
  • Input type
    Differential input
  • Conversion time
    200 µs
  • Digital converter resolution
    12-bit
  • Supported inputs
    Input 2
  • Input
    0 to 20 mA
  • Nominal voltage
    24 VDC
  • Pulse length
    ≥20 µs
  • Counter size
    16-bit
  • Counter frequency
    Max. 50 kHz
  • Evaluation
    Each negative edge, cyclic counter
  • Short-circuit proof
    Yes
  • Integrated protection
    Reverse polarity protection
  • Length of pause between pulses
    ≥100 µs
  • Counter 1
    Input 1
  • Input frequency
    Max. 50 kHz
  • Quantity
    1
  • Signal form
    Square wave pulse
  • Additional functions
    50 kHz event counting, gate measurement
  • Input circuit
    Sink
  • Input voltage
    18 to 30 VDC
  • Input characteristics per EN 61131-2
    Type 1
  • Input resistance
    Typ. 6 kΩ
  • Synchronization between bus systems possible
    Yes
  • Voltage
    I/O power supply minus voltage drop for short-circuit protection
  • Input current at 24 VDC
    Typ. 4 mA
  • Summation current
    Max. 0.5 A
  • Voltage drop for short-circuit protection at 0.5 A
    Max. 2 VDC
  • Hub propagation delay
    0.96 to 1 µs
  • Transfer rate
    100 Mbit/s
  • Variant
    2x M12 interface (hub), 2x female connector on module
  • Voltage range
    18 to 30 VDC
  • Line length
    Max. 100 m between 2 stations (segment length)

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo