X20SI9100 B&R Electronic Components

B&R X20SI9100 X20 safe digital input module, 20 safe type A digital inputs, configurable input filter, 4 pulse outputs, 24 VDC
B&R

Part#:X20SI9100

Manufacturer:B&R

Product Lifecycle:Active

In-stock parts: 4

Jun 16, 2024

About the product: X20 safe digital input module, 20 safe type A digital inputs, configurable input filter, 4 pulse outputs, 24 VDC

Check out the X20SI9100 B&R price in the box on the right side or send a quick quote.

X20SI9100 Product Details

  • Temperature Operation Horizontal mounting orientation
    0 to 60°C
  • Temperature Operation Vertical mounting orientation
    0 to 50°C
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wireless
    <1*10-14 * Number of openSAFETY packets per hour
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wired
    Negligible
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd Per channel
    <1*10-10
  • Relative humidity Transport
    5 to 95%, non-condensing
  • Relative humidity Storage
    5 to 95%, non-condensing
  • Relative humidity Operation
    5 to 95%, non-condensing
  • Temperature Transport
    -40 to 85°C
  • Temperature Derating
    See section "Derating".
  • Temperature Storage
    -40 to 85°C
  • Mounting orientation Vertical
    Yes
  • Mounting orientation Horizontal
    Yes
  • Switching threshold High
    >15 VDC
  • Switching threshold Low
    <5 VDC
  • Input filter Software
    Configurable between 0 and 500 ms
  • Input filter Hardware
    ≤150 μs
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF
    >90%
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 Proof test interval (PT)
    20 years
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFD
    <2*10-5
  • EN ISO 13849-1:2015 Mission time
    Max. 20 years
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL
    SIL 3
  • EN ISO 13849-1:2015 MTTFD
    2500 years
  • EN ISO 13849-1:2015 DC
    >94%
  • EN ISO 13849-1:2015 PL
    PL e
  • Certifications KC
    Yes
  • EN ISO 13849-1:2015 Category
    Cat. 3 when using individual input channels, ; Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
  • Certifications KR
    Yes
  • Certifications DNV
    Temperature: A (0 - 45°C); Humidity: B (up to 100%); Vibration: A (0.7 g); EMC: B (bridge and open deck)
  • Certifications ABS
    Yes
  • Certifications LR
    ENV1
  • Certifications EAC
    Yes
  • Certifications HazLoc
    cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
  • Certifications ATEX
    Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
  • Certifications UL
    cULus E115267; Industrial control equipment
  • Electrical isolation Channel - Channel
    No
  • Power consumption Internal I/O
    1.6 W
  • Certifications Functional safety
    cULus FSPC E361559; Energy and industrial systems; Certified for functional safety; ANSI UL 1998:2013
  • Certifications UKCA
    Yes
  • Electrical isolation Channel - Bus
    Yes
  • Power consumption Bus
    0.4 W
  • Certifications CE
    Yes
  • Blackout mode Standalone mode
    No
  • Blackout mode Function
    Module functionality
  • Diagnostics Inputs
    Yes, using LED status indicator and software
  • Blackout mode Scope
    Module
  • Diagnostics Module run/error
    Yes, using LED status indicator and software
  • System requirements Safety Release
    1.3 or later
  • System requirements mapp Technology Package
    mapp Safety 5.7.0 or later
  • System requirements SafeDESIGNER
    2.71 or later
  • System requirements Automation Runtime
    3.00 or later
  • System requirements Automation Studio
    3.0.81.15 or later
  • Pitch
    25+0.2 mm
  • Note
    Order 2x safety-keyed terminal block separately.; Order 1x safety-keyed bus module separately.
  • Degree of protection per EN 60529
    IP20
  • Installation elevation above sea level
    0 to 2000 m, no limitation
  • RDS(on)
    60 Ω
  • Total nominal current
    200 mA
  • Leakage current when the output is switched off
    0.1 mA
  • Short-circuit current
    100 mAeff
  • Switching voltage
    I/O power supply minus voltage drop due to RDS(on)
  • Output protection
    Shutdown of individual channels in the event of overload or short circuit
  • Nominal output current
    50 mA
  • Peak short-circuit current
    25 A for 5 ms, hardware revision D0 and later: 25 A for 15 µs
  • Line length between signal source (pulse output or external signal) and input
    Max. 60 m with unshielded line; Max. 400 m with shielded line
  • Insulation voltage between channel and bus
    500 Veff
  • Error detection time
    200 ms
  • Input current at 24 VDC
    Min. 2 mA to max. 3.28 mA
  • Input circuit
    Sink
  • Variant
    Type A
  • Input characteristics per EN 61131-2
    Type 1
  • Input resistance
    Min. 7.33 kΩ
  • Voltage range
    24 VDC -15% / +20%
  • Input voltage
    24 VDC -15% / +20%
  • Additional power dissipation caused by actuators (resistive) [W]
    0.6
  • Nominal voltage
    24 VDC
  • Status indicators
    I/O function per channel, operating state, module status
  • B&R ID code
    0xAEC8
  • I/O module
    20 safe type A digital inputs, 4 pulse outputs, 24 VDC
  • Quantity
    20
  • Integrated protection
    Reverse polarity protection
  • Max. I/O cycle time
    1600 µs

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


This item can ship within 3 days!

1-year warranty

$2,893.45

X20SI9100

Stock:

4

Select Qty:

$2,893.45

$2,893.45 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo