About the product: X20 safe digital input module, 20 safe type A digital inputs, configurable input filter, 4 pulse outputs, 24 VDC
Check out the X20SI9100 B&R price in the box on the right side or send a quick quote.
X20SI9100 Product Details
- Temperature Operation Horizontal mounting orientation 0 to 60°C
- Temperature Operation Vertical mounting orientation 0 to 50°C
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wireless <1*10-14 * Number of openSAFETY packets per hour
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wired Negligible
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd Per channel <1*10-10
- Relative humidity Transport 5 to 95%, non-condensing
- Relative humidity Storage 5 to 95%, non-condensing
- Relative humidity Operation 5 to 95%, non-condensing
- Temperature Transport -40 to 85°C
- Temperature Derating See section "Derating".
- Temperature Storage -40 to 85°C
- Mounting orientation Vertical Yes
- Mounting orientation Horizontal Yes
- Switching threshold High >15 VDC
- Switching threshold Low <5 VDC
- Input filter Software Configurable between 0 and 500 ms
- Input filter Hardware ≤150 μs
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF >90%
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 Proof test interval (PT) 20 years
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFD <2*10-5
- EN ISO 13849-1:2015 Mission time Max. 20 years
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL SIL 3
- EN ISO 13849-1:2015 MTTFD 2500 years
- EN ISO 13849-1:2015 DC >94%
- EN ISO 13849-1:2015 PL PL e
- Certifications KC Yes
- EN ISO 13849-1:2015 Category Cat. 3 when using individual input channels, ; Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
- Certifications KR Yes
- Certifications DNV Temperature: A (0 - 45°C); Humidity: B (up to 100%); Vibration: A (0.7 g); EMC: B (bridge and open deck)
- Certifications ABS Yes
- Certifications LR ENV1
- Certifications EAC Yes
- Certifications HazLoc cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
- Certifications ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
- Certifications UL cULus E115267; Industrial control equipment
- Electrical isolation Channel - Channel No
- Power consumption Internal I/O 1.6 W
- Certifications Functional safety cULus FSPC E361559; Energy and industrial systems; Certified for functional safety; ANSI UL 1998:2013
- Certifications UKCA Yes
- Electrical isolation Channel - Bus Yes
- Power consumption Bus 0.4 W
- Certifications CE Yes
- Blackout mode Standalone mode No
- Blackout mode Function Module functionality
- Diagnostics Inputs Yes, using LED status indicator and software
- Blackout mode Scope Module
- Diagnostics Module run/error Yes, using LED status indicator and software
- System requirements Safety Release 1.3 or later
- System requirements mapp Technology Package mapp Safety 5.7.0 or later
- System requirements SafeDESIGNER 2.71 or later
- System requirements Automation Runtime 3.00 or later
- System requirements Automation Studio 3.0.81.15 or later
- Pitch 25+0.2 mm
- Note Order 2x safety-keyed terminal block separately.; Order 1x safety-keyed bus module separately.
- Degree of protection per EN 60529 IP20
- Installation elevation above sea level 0 to 2000 m, no limitation
- RDS(on) 60 Ω
- Total nominal current 200 mA
- Leakage current when the output is switched off 0.1 mA
- Short-circuit current 100 mAeff
- Switching voltage I/O power supply minus voltage drop due to RDS(on)
- Output protection Shutdown of individual channels in the event of overload or short circuit
- Nominal output current 50 mA
- Peak short-circuit current 25 A for 5 ms, hardware revision D0 and later: 25 A for 15 µs
- Line length between signal source (pulse output or external signal) and input Max. 60 m with unshielded line; Max. 400 m with shielded line
- Insulation voltage between channel and bus 500 Veff
- Error detection time 200 ms
- Input current at 24 VDC Min. 2 mA to max. 3.28 mA
- Input circuit Sink
- Variant Type A
- Input characteristics per EN 61131-2 Type 1
- Input resistance Min. 7.33 kΩ
- Voltage range 24 VDC -15% / +20%
- Input voltage 24 VDC -15% / +20%
- Additional power dissipation caused by actuators (resistive) [W] 0.6
- Nominal voltage 24 VDC
- Status indicators I/O function per channel, operating state, module status
- B&R ID code 0xAEC8
- I/O module 20 safe type A digital inputs, 4 pulse outputs, 24 VDC
- Quantity 20
- Integrated protection Reverse polarity protection
- Max. I/O cycle time 1600 µs
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
This item can ship within 3 days!
1-year warranty
$2,893.45
X20SI9100
Stock:
4
Select Qty:
$2,893.45
$2,893.45 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨