X20CP1382 B&R Electronic Components
Part#:X20CP1382
Manufacturer:B&R
Product Lifecycle:Active
Get a quick Quote!
X20 PLC, with integrated I/O, x86-400, 256 MB DDR3 RAM, 32 kB FRAM, 2 GB onboard flash drive, 1 insert slot for X20 interface modules, 2 USB interfaces, 1 RS232 interface, 1 CAN bus interface, 1 POWERLINK interface, 1 Ethernet interface 10/100BASE-T, 14 d
Check out the X20CP1382 B&R price in the box on the right side or send a quick quote.
Product Details
- Weight310 g
- Temperature Operation Vertical mounting orientation -25 to 50°C
- Max. error Voltage Offset 0.04% (Rev.
- Temperature Operation Horizontal mounting orientation
-25 to 60°C- Max. error Current Offset
0 to 20 mA = 0.1% (Rev.- Permissible input signal Current
Max. ±50 mA- Max. gain drift Current
0 to 20 mA = 0.015 %/°C / 4 to 20 mA = 0.023 %/°C- Max. gain drift Voltage
0.017 %/°C- Permissible input signal Voltage
Max. ±30 V- Load Current
<300 Ω- Load Voltage
-- Input impedance in signal range Voltage
20 MΩ- Input impedance in signal range Current
-- Output format Current
INT 0x0000 - 0x7FFF / 1 LSB = 0x0008 = 4.883 μA- Output format Voltage
INT 0x8001 - 0x7FFF / 1 LSB = 0x0008 = 2.441 mV- Digital converter resolution Voltage
±12-bit- Output format Data type
INT- Digital converter resolution Current
12-bit- Switching threshold High
>15 VDC- Switching threshold Low
<5 VDC- Input filter Software
Default 1 ms, configurable between 0 and 25 ms in 0.1 ms increments- Input filter Hardware
Standard inputs and mixed channels: ≤200 μs; High-speed inputs: ≤2 μs, when used as standard inputs: ≤200 μs- Interface IF7 Controller
SJA 1000- Interface IF7 Terminating resistor
Integrated in module- Interface IF7 Transfer rate
Max. 1 Mbit/s- Interface IF7 Max. distance
1000 m- Interface IF7 Variant
Connection via 16-pin terminal block X20TB1F- Interface IF7 Signal
CAN bus- Interface IF6 Fieldbus
X2X Link master- Interface IF5 Max. output current
0.1 A- Interface IF5 Variant
Type A- Interface IF5 Type
USB 1.1/2.0- Interface IF4 Max. output current
0.5 A- Interface IF4 Variant
Type A- Interface IF4 Type
USB 1.1/2.0- Interface IF3 Transfer rate
100 Mbit/s- Interface IF3 Variant
1x RJ45 shielded- Interface IF3 Line length
Max. 100 m between 2 stations (segment length)- Interface IF3 Type
Type 4- Interface IF3 Fieldbus
POWERLINK managing or controlled node- Interface IF2 Transfer rate
10/100 Mbit/s- Interface IF2 Line length
Max. 100 m between 2 stations (segment length)- Interface IF2 Variant
1x RJ45 shielded- Interface IF2 Signal
Ethernet- Interface IF1 Transfer rate
Max. 115.2 kbit/s- Interface IF1 Signal
RS232- Interface IF1 Max. distance
900 m- Interface IF1 Variant
Connection via 16-pin terminal block X20TB1F- Processor L2 cache
128 kB- Application memory Error-correcting code (ECC)
Yes- Application memory Data retention
10 years- Application memory Guaranteed erase/write cycles
20,000- Application memory Type
2 GB eMMC flash memory- Standard memory RAM
256 MB DDR3 SDRAM- Processor Clock frequency
400 MHz- Processor Type
Vx86EX- Certifications EAC
Yes- Certifications ABS
Yes- Certifications KR
Yes- Certifications LR
ENV1- Certifications UL
cULus E115267; Industrial control equipment- Certifications DNV
Temperature: B (0 - 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)- Certifications ATEX
Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X- Certifications HazLoc
cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5- Certifications UKCA
Yes- Power consumption Internal I/O
2.3 W- Support reACTION-capable I/O channels
No- Certifications CE
Yes- Support Visual Components support
Yes- Support ACOPOS support
Yes- Support Controller redundancy
No- Diagnostics Terminating resistor
Yes, using LED status indicator- Diagnostics Temperature
Yes, using software register- Diagnostics Inputs
Analog inputs: Yes, using LED status indicator and software- Diagnostics I/O power supply
Yes, using LED status indicator- Diagnostics POWERLINK
Yes, using LED status indicator- Diagnostics Supply voltage monitoring
Yes, using LED status indicator- Diagnostics Ethernet
Yes, using LED status indicator- Diagnostics RS232 data transfer
Yes, using LED status indicator- Diagnostics CAN bus data transfer
Yes, using LED status indicator- Diagnostics CPU function
Yes, using LED status indicator- Diagnostics Outputs
Digital outputs: Yes, using LED status indicator and software (output error status)- Note
X20 end cover plate (right) included in delivery; 3 X20 terminal blocks (16-pin) included in delivery; Interface module slot cover included in delivery- Degree of protection per EN 60529
IP20- Electrical isolation
Ethernet (IF2), POWERLINK (IF3) and X2X (IF6) isolated from each other, from other interfaces and from PLC; Channel isolated from bus; Channel not isolated from channel or PLC- Braking voltage when switching off inductive loads
Standard outputs and mixed channels: Typ. 45 VDC- Switch-on in the event of overload shutdown or short-circuit shutdown
Standard outputs and mixed channels: Approx. 10 ms (depends on module temperature); High-speed outputs: No switch-on- Peak short-circuit current
Standard outputs and mixed channels: <3 A; High-speed outputs: <20 A- RDS(on)
140 mΩ- Residual voltage
Standard outputs and mixed channels: <0.1 V at nominal current 0.5 A; High-speed outputs: <0.9 V at nominal current 0.1 A- Leakage current when the output is switched off
Standard outputs and mixed channels: 5 µA; High-speed outputs: 25 µA- Diagnostic status
Standard outputs and mixed channels: Output monitoring with 10 ms delay; High-speed outputs: Output monitoring with 10 µs delay- Output circuit
Standard outputs and mixed channels: Source; High-speed outputs: Sink or source- Switching voltage
24 VDC -15% / +20%- Output protection
Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current"); Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")- Total nominal current
Standard outputs and mixed channels: 4 A; High-speed outputs: 0.8 A- Nominal output current
Standard outputs and mixed channels: 0.5 A; High-speed outputs: 0.2 A- Standardized range of values for resistance measurement
0.1 to 4000.0 Ω- Variant
Standard outputs and mixed channels: Current-sourcing FET; High-speed outputs: Push-Pull- Nonlinearity
<0.05%- Max. offset drift
0.012%/°C- Measurement current
1 mA- Resistance measurement resolution
1 LSB = 0x0005 = 0.49 Ω- Max. gain drift
0.023 %/°C- Linearization method
Internal- Permissible input signal
Short-term max. ±30 V- Sensor standard
EN 60751- Temperature sensor resolution
1 LSB = 0x0005 = 0.16°C- Output format
INT or UINT for resistance measurement- Resistance measurement range
0.1 to 4000 Ω- Crosstalk between channels
<-70 dB- Digital converter resolution
13-bit- Input voltage
24 VDC -15% / +20%- Common-mode range
±12 V- Output of digital value during overload
Configurable- Conversion procedure
SAR- Input filter
Third-order low-pass filter / Cutoff frequency 1 kHz- Input protection
Protection against wiring with supply voltage- Type of signal lines
Shielded lines must be used for all high-speed digital inputs/outputs, line length: Max. 20 m- Conversion time
1 channel enabled: 100 µs; 2 channels enabled: 200 µs- Max. error Current Gain
0 to 20 mA = 0.15% (Rev.- Max. error Voltage Gain
0.18% (Rev.- Interface IF3 Transfer Auto-MDI/MDIX
Yes- Interface IF3 Transfer Autonegotiation
Yes- Interface IF3 Transfer Full-duplex
POWERLINK mode: No / Ethernet mode: Yes- Interface IF3 Transfer Half-duplex
Yes- Interface IF2 Transfer Auto-MDI/MDIX
Yes- Interface IF2 Transfer Full-duplex
Yes- Interface IF2 Transfer Autonegotiation
Yes- Interface IF3 Transfer Physical layer
100BASE-TX- Interface IF2 Transfer Half-duplex
Yes- Interface IF2 Transfer Physical layer
10BASE-T/100BASE-TX- Application memory Writable data amount Results for 5 years
21.9 GB/day- Application memory Writable data amount Guaranteed
40 TB- Processor L1 cache Program code
16 kB- Processor L1 cache Data code
16 kB- Relative humidity Operation
5 to 95%, non-condensing- Dimensions Height
99 mm- Relative humidity Transport
5 to 95%, non-condensing- Dimensions Depth
75 mm- Dimensions Width
164 mm- Temperature Storage
-40 to 85°C- Temperature Transport
-40 to 85°C- Relative humidity Storage
5 to 95%, non-condensing- Temperature Derating
See section "Switching frequency derating for high-speed digital outputs".- Mounting orientation Vertical
Yes- Mounting orientation Horizontal
Yes- Installation elevation above sea level 0 to 2000 m
No limitation- Installation elevation above sea level >2000 m
Reduction of ambient temperature by 0.5°C per 100 m- Switching frequency Inductive load
See section "Switching inductive loads".- Switching frequency Resistive load
Standard outputs and mixed channels: Max. 500 Hz; High-speed outputs: 50 kHz, max. 200 kHz (see section "Switching frequency derating for high-speed digital outputs")- Switching delay 1 → 0
Standard outputs and mixed channels: <300 µs; High-speed outputs: <3 µs- Pulse width modulation Period duration
5 to 65535 µs corresponds to 200 kHz to 15 Hz- Pulse width modulation Pulse duration
0 to 100%, minimum 2.5 µs- Switching delay 0 → 1
Standard outputs and mixed channels: <300 µs; High-speed outputs: <3 µs- Pulse width modulation Resolution for pulse duration
0.1% of the configured frequency- Temperature sensor normalization Pt1000
-200 to 850°C- Sensor Pt1000
-200 to 850°C- Max. error at 25°C Offset
0.15% (Rev.- Nonlinearity Voltage
<0.025%- Nonlinearity Current
<0.05%- Max. error at 25°C Gain
0.3% (Rev.- Max. offset drift Current
0 to 20 mA = 0.008 %/°C / 4 to 20 mA = 0.012 %/°C- Common-mode rejection 50 Hz
70 dB- Common-mode rejection DC
70 dB- Max. offset drift Voltage
0.008 %/°C- Input
±10 V or 0 to 20 mA / 4 to 20 mA, via different terminal connections- Input type
Differential input- Power consumption for X2X Link power supply
0.8 W- Measurements per module
Each function up to 2x- Status indicators
CPU function, Ethernet, POWERLINK, RS232, CAN bus, CAN bus terminating resistor, PLC power supply, I/O power supply, I/O function per channel- Counter frequency
250 kHz- Timestamp
1 µs resolution- Possible measurements
Period measurement, gate measurement, differential time measurement, edge counter, edge times- Signal form
Square wave pulse- Encoder inputs
24 V, asymmetrical- Input frequency
Max. 100 kHz- Counter size
32-bit- Encoder power supply
Module-internal, max. 300 mA- Power consumption without interface module and USB
5.5 W- Evaluation
4x- Overload characteristics of encoder power supply
Short-circuit proof, overload-proof- Additional functions
X2 - High-speed digital inputs:; 2x 250 kHz event counting, 2x AB counter, ABR incremental encoder, direction/frequency, period measurement, gate measurement, differential time measurement, edge counters, edge times- Input resistance
X1 - Standard inputs: 6.8 kΩ; X2 - Standard inputs: 8.9 kΩ; X2 - High-speed inputs: 6.8 kΩ; X3 - Mixed channels: 8.9 kΩ- Input circuit
Sink- Connection type
1-wire connections- Input current at 24 VDC
X1 - Standard inputs: Typ. 3.5 mA; X2 - Standard inputs: Typ. 2.68 mA; X2 - High-speed inputs: Typ. 3.5 mA; X3 - Mixed channels: Typ. 2.68 mA- Nominal voltage
24 VDC- Shortest task class cycle time
1 ms- Typical instruction cycle time
0.0199 µs- Quantity
14 standard inputs, 4 high-speed inputs and 4 mixed channels, configuration as input or output using software- Remanent variables
32 kB FRAM, retention >10 years- Modular interface slots
1- Integrated I/O processor
Processes I/O data points in the background- FPU
Yes- Real-time clock
Retention for at least 300 hours, typ. 1000 hours at 25°C, 1 s resolution, -18 to 28 ppm accuracy at 25°C- Permissible contact load
10 A- Nominal output voltage
24 VDC- Parallel connection
Yes- Redundant operation
Yes- System module
Controller- Fuse
Integrated, cannot be replaced- Nominal output power
2 W- Input current
Max. 1 A- Reverse polarity protection
Yes- B&R ID code
0xDABB- Interfaces
1x RS232, 1x Ethernet, 1x POWERLINK, 2x USB, 1x X2X Link, 1x CAN bus- Cooling
FanlessProduct condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents X20CP1382 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.