Filters
Manufacturer
IO Type
Input Type
Output Type
Network Protocol
I/O Modules
part#
description
manufacturer
BL67-4IOL
BL67 Electronic Module, 4 IO-Link Master Channels, 16 Bytes of I/O Data, 4 Configurable Digital Channels, PNP, Channel Diagnostics, 0.5 A, Independent of the type of fieldbus and connection technology used, Protection class IP67, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 4 IO-Link master acc. to specification V1.1, 4 universal digital channels, PNP, channel diagnostics, 0.5 A
Turck
Quick Quote
MT16-2G/MSA
excom I/O System, Module Rack, Zone 1, for 16 Modules, Marine Ship Approved, , Module rack for max. 16 I/O modules, 2 gateways and 2 power supply modules, The terminals for the signal connection level are available as accessories, Module rack approved for maritime applications (certification according to GL, DNV, BV and LR)
Turck
Quick Quote
BL67-16DI-P
BL67 electronic module, 16 Digital Inputs, PNP, , Independent of the type of fieldbus and connection technology used, Protection class IP67, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 16 digital inputs, 24 VDC, PNP, From version VN 01-01 and higher, the module supports accelerated start-up for applications with Fast Start-Up (FSU) and QuickConnect (QC).
Turck
Quick Quote
BM1
excom I/O System, Dummy Module, , Dummy module for unused slots on the module rack
Turck
Quick Quote
BL67-B-4M12-P
BL67 base module, 4 × M12 Connector, 5-pin, Paired, , Passive connection components for sensors and actuators, Quick replacement of electronics in wired state, Mechanical coding prevents accidental plugging of the wrong electronic module, Protection class IP67, M12 connection technology, 5-pin, 4 slots, Pairwise assignment
Turck
Quick Quote
BL20-E-4IOL-10
BL20 Economy Module, 4 IO-Link Master Channels, 32 Bytes of I/O Data, 4 Configurable Digital Channels, PNP, Channel Diagnostics, 0.5 A, Fieldbus-independent, Electronics and connection technology in one housing, Connectivity: Push-in terminals, Protection class IP20, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, IO-Link master acc. to specification V1.1, 4-channel, 4 universal digital channels, PNP, channel diagnostics, 0.5 A
Turck
Quick Quote
DI80-N
excom I/O System, Input Module, Digital, 8-channel, , Input module for 3-wire sensors (NPN and PNP), Supply of sensors reverse polarity protected via auxiliary power
Turck
Quick Quote
BL67-4AO-V
BL67 electronic module, 4 Analog Outputs for Voltage, , Independent of the type of fieldbus and connection technology used, Protection class IP67, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 4 analog outputs, -10/0…+10 VDC
Turck
Quick Quote
BL67-8DO-R-NO
BL67 electronic module, 8 Isolated Relay Outputs, NO, , Independent of the type of fieldbus and connection technology used, Protection class IP67, LEDs for status display, Electronics galvanically separated from the field level via optocouplers, 8 isolated relay outputs, Potential-free electronic relay contact (MOSFET), Max. 0.1A
Turck
Quick Quote
BL20-P4S-SBBC-B
BL20 base module, Screw connection, , Passive connection components for sensors and actuators, Quick replacement of electronics in wired state, Mechanical coding prevents plugging of wrong electronic module, Protection class IP20, Screw connection, Disc design, Access to C rail
Turck
Quick Quote
AOH40-N
excom I/O System, Output Module, Analog, HART, 4-channel, , Output module for the connection of analog actuators, Transmission of HART data
Turck
Quick Quote
BL67-8XSG-P
BL67 electronic module, 8 Configurable Digital Channels, PNP, 0.5 A, , Independent of the type of fieldbus and connection technology used, Protection class IP67, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 8 configurable digital channels, 24 VDC, PNP, Max. 0.5 A, Adjustable filter times, Invertible inputs, From version VN 01-01 and higher, the module supports accelerated start-up for applications with Fast Start-Up (FSU) and Quic
Turck
Quick Quote
PSM24-N.1
excom I/O System, Power Supply Module, 24 VDC, Non-Ex, , DC power supply module, supplies a module rack in the non-Ex area
Turck
Quick Quote
BL20-E-16GNDL
BL20 Economy Module, Potential Distribution Module, 16x GND, , Fieldbus-independent, Electronics and connection technology in one housing, Connectivity: Push-in terminals, Protection class IP20, 16 connection terminals for wiring the GND potential from the U, L, field supply
Turck
Quick Quote
TBEN-S1-8DXP
Compact Multiprotocol I/O Module for Ethernet, 8 Universal Digital Channels, Configurable as PNP Inputs or 2 A Outputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps / 100 Mbps, 2x M8, 4-pin, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 4-pin M8 male connector for power supply, Galvanically isolated voltage groups, ATEX Zone
Turck
Quick Quote
AO40-N
excom I/O System, Output Module, Analog, 4-channel, , Output module for the connection of analog actuators, Complete galvanic isolation
Turck
Quick Quote
AI41-N
excom I/O System, Input Module, Analog, Passive, 4-channel, , Input module for the connection of active transmitters (passive inputs), Complete galvanic isolation
Turck
Quick Quote
AI401EX
excom I/O System, Input Module, Analog, 4-channel, , Input module for the connection of passive transmitters (active inputs) or active transmitters (passive inputs)., Complete galvanic isolation
Turck
Quick Quote
BL67-B-2M12-8
BL67 base module, 2 × M12 Connector, 8-pin, , Passive connection components for sensors and actuators, Quick replacement of electronics in wired state, Mechanical coding prevents accidental plugging of the wrong electronic module, Protection class IP67, M12 connection technology, 8-pin, 2 slots
Turck
Quick Quote
BL67-2RFID-S
BL67 Electronic Module, 2 RFID Channels (HF/UHF), Cable length (L) 50 m, A special software (function module) for integration in PLC systems is not required., 8 byte user data per read/write cycle, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, Connection of two BL ident read/write heads, Mixed operation of HF and UHF read/write heads, Transmission rate: 115.2 kbps, Cable length max. 50 m
Turck
Quick Quote
Items per page:
I/O Modules
General Guide & Overview
In the world of control systems, I/O modules play a crucial role in facilitating the seamless exchange of data between the control system and external devices. These modules come in various types and offer a wide range of functionalities to meet the specific automation needs of different industries.
Before we dive into the types and options available, let's explore the fundamental functions of I/O modules. These modules serve as the intermediaries between the control system and sensors, actuators, and other peripheral devices. They ensure efficient communication, allowing the control system to receive input signals from sensors and provide output signals to actuators for precise control and automation.
Now, let's take a closer look at the different types of I/O modules. There are digital I/O modules, analog I/O modules, and specialty I/O modules. Digital I/O modules handle binary signals, such as on/off or high/low, while analog I/O modules process continuous signals like voltage or current. Specialty I/O modules are designed for specific purposes, such as temperature sensing or motor control.
When selecting an I/O module, it's important to consider the specific requirements of your control system. Factors such as the number of I/O points, communication protocols, and compatibility with the control system should all be taken into account.
With the rapid advancement of technology, I/O modules now come with a multitude of options. These options include various communication interfaces like Ethernet, USB, or serial ports, as well as additional features such as built-in diagnostics, hot-swapping capabilities, and LED indicators for easy troubleshooting.
In the next sections, we will explore the installation and management of I/O modules, as well as delve into the supported I/O modules and their features. So, keep reading to gain a comprehensive understanding of I/O modules and how they can enhance your control systems.
Installation and Management of I/O Modules
Proper setup, installation, and management of I/O modules is essential to ensure their correct functioning and compatibility with the control system. To achieve optimal performance, follow these key steps:
I/O Module Setup
1. Identify the specific I/O module required for your system based on the desired functionality.
2. Consult the manufacturer's documentation to verify compatibility with your control system and ensure that any required software or firmware updates are performed.
3. Determine the appropriate physical location for the I/O module, considering factors such as cable lengths, environmental conditions, and accessibility for maintenance and troubleshooting.
4. Connect the I/O module to the control system using the provided cables, ensuring proper alignment and secure connections.
I/O Module Installation
1. Power off the control system and any devices connected to it.
2. Insert the I/O module into the designated slot, following the manufacturer's instructions. Take note of any specific alignment or positioning requirements.
3. Secure the I/O module in place using the provided mounting brackets, ensuring a stable and vibration-free installation.
4. Power on the control system and verify that the I/O module is detected and recognized by the system.
I/O Module Management
1. Access the control system's configuration software or interface to manage and monitor the I/O module.
2. Configure the I/O module settings, such as input/output assignments, signal range, and communication protocols, according to the system requirements.
3. Regularly check the status and health of the I/O module, monitoring for any errors, malfunctions, or communication issues.
4. Perform firmware updates and maintenance tasks as recommended by the manufacturer to ensure optimal performance and reliability.
By following these installation and management guidelines, you can ensure the proper setup, installation, and ongoing functionality of your I/O modules within your control system.
Supported I/O Modules and their Features
When it comes to control systems and automation, having the right I/O modules is crucial. These modules offer a range of features and functionalities to meet specific system requirements. Let's take a closer look at some of the supported optional I/O modules and what they bring to the table.
One important aspect to consider is the I/O module's features. Different modules offer a variety of capabilities, such as analog input/output, digital input/output, temperature input, and specialty input/output. These features ensure that the I/O module can effectively communicate with and control external devices as needed, enabling seamless integration within the control system.
In addition to features, I/O modules also come with various ports for connectivity. These ports allow for easy communication and data exchange between the module and external devices. Some common ports include Ethernet ports for network connectivity, serial ports for device communication, and USB ports for easy configuration and firmware updates.
When working with I/O modules, visual feedback is essential. That's why many modules come equipped with LEDs. These LEDs provide status indicators, such as power, communication, and module health. They offer a quick and convenient way to monitor the module's operation and ensure everything is functioning as expected.
FAQ
What are I/O modules?
I/O modules are essential components in control systems that facilitate the exchange of data between the control system and external devices.
What are the major functions of an I/O module?
The major functions of an I/O module include data exchange between the control system and external devices, data buffering, data format conversion, and error detection and reporting.
What types of I/O modules are available?
There are various types of I/O modules available, including digital I/O modules, analog I/O modules, and interrupt-driven I/O modules.
How should I set up and install I/O modules?
Proper setup and installation of I/O modules are crucial for ensuring correct functioning and compatibility with the control system. It is recommended to follow the manufacturer's instructions and guidelines for installation.
How do I manage I/O modules?
I/O module management involves tasks such as configuring settings, monitoring module performance, and troubleshooting any issues that may arise.
What are some of the supported I/O modules and their features?
Supported I/O modules offer various features and functionalities to cater to specific system requirements. Some examples include modules with different types of ports such as digital and analog inputs and outputs, and modules with LED indicators for status monitoring.