Filters
Manufacturer
Current (AC-1)
Current (AC-3)
Number of Poles
UL Certification
More in this category
Contactors
part#
description
manufacturer
LC1D40AY7
Schneider Electric LC1D40AY7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) device with a rated current of 60A for AC-1 and 40A for 440Vac in AC-3. This contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection rated at IP20. The control voltage (AC) ranges from 552-759Vac at 50Hz and 586.5-759Vac at 60Hz, with a nominal voltage of 690Vac. The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D40AY7 is up to 6,000,000 operations, and its electrical durability with load reaches 1,500,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D40AW7
Schneider Electric LC1D40AW7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) range of 222-304Vac (277Vac nominal; 50Hz; 0.8...1.1 x Uc) and 236-304Vac (277Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it comes with 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated current is 60A (AC-1) and 40A (440Vac; AC-3), with a rated impulse voltage (Uimp) of 6 kV. It supports rated active power of up to 30kW (660-690Vac; AC-3) and rated power in horsepower ranging from 3HP to 30HP across various voltages and phases, as specified. The mechanical durability of the LC1D40AW7 is rated at 6,000,000 operations, and its electrical durability (with load) is rated at 1,500,000 operations.
Schneider Electric
Quick Quote
LC1D40AUD
Schneider Electric LC1D40AUD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. This 3-pole (3P; 3NO) contactor is rated for currents of 60A (AC-1) and 40A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. It has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (DC) ranges from 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc), and it operates at a rated voltage (Ue) of up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. This contactor is designed for mechanical durability of 6 million operations at no load and electrical durability of 1.5 million operations with load, with a phase-to-phase rated voltage of 690 V.
Schneider Electric
Quick Quote
LC1D40ASD
Schneider Electric LC1D40ASD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections. This 3-pole (3P; 3NO) contactor supports a rated current of 60A for AC-1 applications and 40A for 440Vac in AC-3 scenarios. It is designed for DIN rail mounting, with a net width of 55 mm and an IP20 degree of protection. The control voltage (DC) ranges from 54-90Vdc, with a nominal value of 72Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) stands at 6 kV. Its rated active power capacity spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3. It also features 1 normally closed (NC) auxiliary contact with 1NO+1NC instantaneous auxiliary contacts type. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase applications, according to UL/CSA standards. The mechanical durability of the LC1D40ASD is rated at 6 million operations at no load, and its electrical durability with load is rated at 1.5 million operations. The rated voltage (AC) for phase-to-phase applications is 690 V.
Schneider Electric
Quick Quote
LC1D40ASC7
Schneider Electric LC1D40ASC7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and screw connections. It is a 3-pole (3P; 3NO) device with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 460-632Vac (575Vac nominal; 50Hz; 0.8...1.1 x Uc) to 489-632Vac (575Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW (220-230Vac; AC-3) to 30kW (660-690Vac; AC-3), and the rated power (HP) ranges from 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability at no load is 6,000,000 operations, and the electrical durability with load is 1,500,000 operations. The rated voltage (AC) - phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D40ARD
Schneider Electric LC1D40ARD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. This 3-pole (3P; 3NO) contactor supports a rated current of 60A (AC-1) and 40A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. It has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (DC) ranges from 330-550Vdc (440Vdc nominal; 0.75...1.25 x Uc), and the rated operating voltage (Ue) is up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D40ARD is up to 6 million operations at no load, and its electrical durability reaches 1.5 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D40AND
Schneider Electric LC1D40AND is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminals and screw connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) of 45-75Vdc (60Vdc nom.; 0.75...1.25 x Uc). The LC1D40AND is rated for currents of 60A (AC-1) and 40A (440Vac; AC-3), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D40AND is rated at 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D40AMD
Schneider Electric LC1D40AMD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 60A for AC-1 and 40A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 165-275Vdc (220Vdc nominal; 0.75...1.25 x Uc), and the rated operating voltage (Ue) is up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor supports rated active power ranging from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3, and rated power (HP) from 3HP at 115Vac to 30HP at 575-600Vac, according to UL/CSA standards for single-phase and 3-phase connections. It boasts a mechanical durability of 6,000,000 operations and an electrical durability of 1,500,000 operations with load, with a phase-to-phase rated voltage (AC) of 690 V.
Schneider Electric
Quick Quote
LC1D40AK7
Schneider Electric LC1D40AK7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and screw connections. This 3-pole (3P; 3NO) contactor is designed for a rated current of 60A (AC-1) and 40A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. It has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 80-110Vac (100Vac nominal; 50Hz; 0.8...1.1 x Uc) to 85-110Vac (100Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW (220-230Vac; AC-3) to 30kW (660-690Vac; AC-3), and the rated power (HP) ranges from 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability is specified at 6,000,000 operations, with electrical durability (with load) at 1,500,000 operations. The rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D40AJ5
Schneider Electric LC1D40AJ5 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 60A for AC-1 and 40A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 9.6-13.2Vac (12Vac nominal; 50Hz; 0.8...1.1 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. The rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3. It also features 1 normally closed (NC) auxiliary contact with a contact type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in 3-phase, according to UL/CSA standards. Its mechanical durability is rated at 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D40AFD
Schneider Electric LC1D40AFD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections. This 3-pole (3P; 3NO) contactor supports a rated current of 60A for AC-1 and 40A for AC-3 at 440Vac. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D40AFD offers a degree of protection of IP20 and operates with a control voltage (DC) range of 82.5-137.5Vdc (110Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3. It also supports rated power in horsepower (HP) for various voltages and phases under UL/CSA standards. The mechanical durability of the LC1D40AFD is rated at 6 million operations at no load, and its electrical durability is rated at 1.5 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D40AED
Schneider Electric LC1D40AED is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 60A for AC-1 and 40A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers an IP20 degree of protection. The control voltage (DC) ranges from 36-60Vdc, with a nominal 48Vdc, and it operates at a rated voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power reaches up to 30kW for 660-690Vac in AC-3, and the rated power in horsepower varies from 3HP to 30HP across different voltages and phases, according to UL/CSA standards. The mechanical durability of the LC1D40AED is rated at 6 million operations, and its electrical durability with load is 1.5 million operations. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D40ACD
Schneider Electric LC1D40ACD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) device with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). This contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) of 27-45Vdc (36Vdc nom.; 0.75...1.25 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. It also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac to 30HP at 575-600Vac, covering both single-phase and 3-phase applications. The mechanical durability of the LC1D40ACD is rated at 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) for phase-to-phase applications is 690 V.
Schneider Electric
Quick Quote
LC1D40AC7
Schneider Electric LC1D40AC7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) device with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). This contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) of 25.6-35.2Vac (32Vac nom.; 50Hz; 0.8...1.1 x Uc) and 27.2-35.2Vac (32Vac nom.; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW (220-230Vac; AC-3) to 30kW (660-690Vac; AC-3), and the rated power (HP) spans from 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability of the LC1D40AC7 is rated at 6,000,000 operations, and its electrical durability (with load) is 1,500,000 operations. The rated voltage (AC) - phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D40A6V7
Schneider Electric LC1D40A6V7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor is rated for currents of 60A (AC-1) and 40A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. It has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 320-440Vac (400Vac nominal; 50Hz; 0.8...1.1 x Uc) to 340-440Vac (400Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D40A6V7 is up to 6,000,000 operations, and its electrical durability with load reaches 1,500,000 operations. The rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D40A6Y7
Schneider Electric LC1D40A6Y7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) range of 552-759Vac (690Vac nominal; 50Hz; 0.8...1.1 x Uc) and 586.5-759Vac (690Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated current is 60A (AC-1) and 40A (440Vac; AC-3), with a rated impulse voltage (Uimp) of 6 kV. It supports rated active power of up to 30kW (660-690Vac; AC-3) and rated power (HP) up to 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability of the LC1D40A6Y7 is rated at 6,000,000 operations, and its electrical durability (with load) is rated at 1,500,000 operations.
Schneider Electric
Quick Quote
LC1D40A6SD
Schneider Electric LC1D40A6SD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 54-90Vdc (72Vdc nominal; 0.75...1.25 x Uc). The LC1D40A6SD is rated for a current of 60A (AC-1) and 40A (440Vac; AC-3), with a rated operating voltage (Ue) of up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D40A6SD is rated at 6 million operations, and its electrical durability with load is rated at 1.5 million operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D40A6S7
Schneider Electric LC1D40A6S7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 400-550Vac (500Vac nominal; 50Hz; 0.8...1.1 x Uc) and 425-550Vac (500Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated current is 60A (AC-1) and 40A (440Vac; AC-3), with a rated impulse voltage (Uimp) of 6 kV. It supports rated active power outputs of 11kW (220-230Vac; AC-3) up to 30kW (660-690Vac; AC-3) and rated power in horsepower ranging from 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability of the LC1D40A6S7 is rated at 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D40A6R7
Schneider Electric LC1D40A6R7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 60A for AC-1 and 40A for AC-3 at 440Vac. It is designed for DIN rail mounting with a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 352-484Vac at 50Hz and 374-484Vac at 60Hz, with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power reaches up to 11kW at 220-230Vac, 18.5kW at 380-400Vac, 22kW at 415-440-500Vac, and 30kW at 660-690Vac, all in AC-3. The rated power in horsepower (HP) varies from 3HP at 115Vac to 30HP at 575-600Vac, covering both single-phase and 3-phase applications under UL/CSA standards. The mechanical durability of the LC1D40A6R7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.5 million operations with load. The rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D40A6RD
Schneider Electric LC1D40A6RD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor is rated for currents of 60A (AC-1) and 40A (440Vac; AC-3), and can be mounted on a DIN rail. It has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 330-550Vdc (440Vdc nominal; 0.75...1.25 x Uc), with a rated operating voltage (Ue) of up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D40A6RD is rated at 6 million operations at no load, and its electrical durability is rated at 1.5 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
Items per page: