Filters
Manufacturer
Current (AC-1)
Current (AC-3)
Number of Poles
UL Certification
More in this category
Contactors
part#
description
manufacturer
LC1D50A3LE7
Schneider Electric LC1D50A3LE7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). The contactor is rated for currents of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A3LE7 offers a degree of protection rated at IP20 and operates with a control voltage range of 167-228Vac at 50Hz and 176.8-228.8Vac at 60Hz. Its rated operating voltage (Ue) reaches up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type. The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. It supports various rated powers in horsepower (HP) for different voltages and phases, including 3HP at 115Vac and up to 40HP at 575-600Vac. The mechanical durability of the LC1D50A3LE7 is rated at 6 million operations without load, and its electrical durability with load is 1.45 million operations. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50A3L7
Schneider Electric LC1D50A3L7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It offers spring connections for control and screw connections for power, with a 3-pole (3P; 3NO) configuration. The rated current is 80A for AC-1 and 50A for 440Vac in AC-3, designed for DIN rail mounting. The net width of the contactor is 55 mm, and it has an IP20 degree of protection. Control voltage ranges from 160-220Vac at 50Hz and 170-220Vac at 60Hz, with a nominal control voltage of 200Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3. It also features 1 normally closed (NC) auxiliary contact with instantaneous aux. contacts type 1NO+1NC. Rated power in horsepower (HP) ranges from 3HP at 115Vac to 40HP at 575-600Vac, suitable for both single-phase and 3-phase systems under UL/CSA standards. Mechanical durability is rated at 6 million operations, and electrical durability at 1.45 million operations with load. The rated voltage for phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D50A3K7
Schneider Electric LC1D50A3K7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and operates with 3 poles (3P; 3NO). The contactor is rated for currents of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A3K7 offers an IP20 degree of protection and operates with a control voltage of 80-110Vac at 50Hz and 85-110Vac at 60Hz. Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. It also supports rated power in horsepower (HP) for various voltages and phases, including 3HP at 115Vac and up to 40HP at 575-600Vac. The mechanical durability of the LC1D50A3K7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.45 million operations with load. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50A3GD
Schneider Electric LC1D50A3GD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for connection. It is equipped with spring connections for control and screw connections for power. This contactor has 3 poles (3P; 3NO) and is rated for currents of 80A (AC-1) and 50A (440Vac; AC-3). It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. The control voltage (DC) ranges from 94-156Vdc (125Vdc nominal; 0.75...1.25 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. The rated active power (kW) spans from 15kW at 220-230Vac to 33kW at 660-690Vac, all under AC-3 classification. It also has 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power (HP) varies from 3HP at 115Vac to 40HP at 575-600Vac, with specifications for both single-phase and 3-phase systems under UL/CSA standards. The mechanical durability is rated at 6,000,000 operations, and electrical durability with load is 1,450,000 operations. The rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D50A3G7
Schneider Electric LC1D50A3G7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for connection. It is equipped with spring connections for control and screw connections for power. This 3-pole (3P; 3NO) contactor supports a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A3G7 offers a degree of protection rated at IP20 and operates with a control voltage of 96-132Vac (120Vac nominal; 50Hz; 0.8...1.1 x Uc) and 102-132Vac (120Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. It also supports rated power in horsepower (HP) for various voltages and phases, including 3HP at 115Vac and up to 40HP at 575-600Vac, under UL/CSA standards. The mechanical durability of the LC1D50A3G7 is rated at 6 million operations, and its electrical durability with load is 1.45 million operations. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50A3FE7
Schneider Electric LC1D50A3FE7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for connection. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). The rated current is 80A for AC-1 and 50A for 440Vac in AC-3, with a mounting mode designed for DIN rail installation. The net width of the contactor is 55 mm, and it offers a degree of protection rated at IP20. Control voltage ranges from 92-126Vac at 115Vac nominal for 50Hz and 98-126Vac at 115Vac nominal for 60Hz. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Rated active power varies with voltage, offering 15kW at 220-230Vac, 22kW at 380-400Vac, 25kW at 415Vac, 30kW at 440Vac and 500Vac, and 33kW at 660-690Vac in AC-3. It also has 1 normally closed (NC) auxiliary contact with a contact type of 1NO+1NC instantaneous aux. Rated power in horsepower (HP) includes 3HP at 115Vac single-phase, 7.5HP at 230-240Vac single-phase, 15HP at 200-208Vac and 230-240Vac 3-phase, and 40HP at 460-480Vac and 575-600Vac 3-phase, all under UL/CSA standards. Mechanical durability is rated at 6 million operations at no load, and electrical durability at 1.45 million operations with load. The rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D50A3FC7
Schneider Electric LC1D50A3FC7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for connection. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). The contactor is rated for 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. The control voltage (AC) ranges from 102-139Vac at 50Hz and 108-139Vac at 60Hz, with a nominal voltage of 127Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. It supports rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, according to UL/CSA standards. The mechanical durability of the contactor is up to 6,000,000 operations, and its electrical durability with load reaches 1,450,000 operations. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50A3F7
Schneider Electric LC1D50A3F7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). The contactor is rated for currents of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A3F7 offers an IP20 degree of protection and operates with a control voltage of 88-121Vac at 50Hz and 93.5-121Vac at 60Hz. Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. It supports rated power in horsepower (HP) from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, according to UL/CSA standards. The mechanical durability of the LC1D50A3F7 is rated at 6 million operations without load, and its electrical durability with load is 1.45 million operations. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50A3ED
Schneider Electric LC1D50A3ED is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). The contactor is rated for currents of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A3ED offers an IP20 degree of protection and operates with a control voltage of 36-60Vdc (48Vdc nominal). Its rated operating voltage (Ue) reaches up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. It also features 1 normally closed (NC) auxiliary contact and instantaneous auxiliary contacts type 1NO+1NC. The rated power in horsepower varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, according to UL/CSA standards. Its mechanical durability is rated at 6 million operations, and its electrical durability with load is 1.45 million operations. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50A3D7
Schneider Electric LC1D50A3D7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design with spring connections for control and screw connections for power. This 3-pole (3P; 3NO) contactor supports a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A3D7 offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 33.6-46.2Vac at 50Hz and 35.7-46.2Vac at 60Hz, with a nominal voltage of 42Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. It also supports rated power in horsepower (HP) for various voltages and phases under UL/CSA standards, including 3HP at 115Vac single-phase and up to 40HP at 575-600Vac 3-phase. The mechanical durability of the LC1D50A3D7 is rated at 6,000,000 operations, and its electrical durability with load is 1,450,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50A3CD
Schneider Electric LC1D50A3CD is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminals. It is designed with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor supports a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is suitable for DIN rail mounting and has a net width of 55 mm. The LC1D50A3CD offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 27-45Vdc (36Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) reaches up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. It also features 1 normally closed (NC) auxiliary contact with a contact type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, according to UL/CSA standards. Its mechanical durability is rated at 6 million operations at no load, and its electrical durability at 1.45 million operations with load. The rated voltage (AC) for phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D50A3B7
Schneider Electric LC1D50A3B7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). The contactor is rated for 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. Control voltage ranges from 19.2-26.4Vac at 50Hz and 20.4-26.4Vac at 60Hz, with a nominal control voltage of 24Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. Rated power in horsepower (HP) ranges from 3HP at 115Vac single-phase to 40HP at 575-600Vac three-phase, according to UL/CSA standards. Mechanical durability is rated at 6 million operations at no load, and electrical durability is rated at 1.45 million operations with load. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D506K7
Schneider Electric LC1D506K7 is a magnetic contactor from the Deca sub-range, designed for ring-lugs connections. It features 3 poles (3P; 3NO) and is suitable for mounting on a DIN rail. The contactor has a rated current of 80A for AC-1 applications and 50A for AC-3 applications at 440Vac. It offers a degree of protection of IP20 and operates with a control voltage range of 80-110Vac at 50Hz and 85-110Vac at 60Hz. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power reaches up to 33kW for AC-3 applications across various voltages, and the rated power in horsepower (HP) spans from 3HP in single-phase to 40HP in three-phase applications, compliant with UL/CSA standards. The mechanical durability of the LC1D506K7 is rated at 15 million operations at no load, and its phase-to-phase rated voltage is 690 V.
Schneider Electric
Quick Quote
LC1D506M7
Schneider Electric LC1D506M7 is a magnetic contactor from the Deca sub-range designed for efficient operation. It features ring-lugs connections and is equipped with 3 poles (3P; 3NO), supporting a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. This contactor is suitable for DIN rail mounting and offers an IP20 degree of protection. The control voltage (AC) ranges from 176-242Vac at 50Hz and 187-242Vac at 60Hz, with a nominal voltage of 220Vac. It operates at a rated operating voltage (Ue) of up to 690 V and includes 1 Normally Open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power capacity spans from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. Additionally, it features 1 Normally Closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, according to UL/CSA standards. Its mechanical durability is rated at 15,000,000 operations at no load, and the rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D506FW
Schneider Electric LC1D506FW is a magnetic contactor from the Deca sub-range designed with a wide-range coil (0.75-1.2 x Uc) for flexibility in control voltage, which ranges from 82.5-132Vdc (110Vdc nominal). It features ring-lugs connections for secure wiring and is equipped with 3 poles (3P; 3NO) suitable for various applications. The contactor supports a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and offers an IP20 degree of protection. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power capacity spans from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. Additionally, it has 1 Normally Closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac to 40HP at 575-600Vac, accommodating a wide range of motor applications. The mechanical durability of the LC1D506FW is rated at 15 million operations at no load, and its phase-to-phase rated voltage (AC) reaches up to 690 V.
Schneider Electric
Quick Quote
LC1D40Q7
Schneider Electric LC1D40Q7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 60A (AC-1) and 40A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 304-418Vac (380Vac nominal; 50Hz; 0.8...1.1 x Uc) and 323-418Vac (380Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power (kW) spans from 11kW at 220-230Vac to 30kW at 660-690Vac, all under AC-3 classification. The rated power (HP) ranges from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, compliant with UL/CSA standards. The mechanical durability of this contactor is rated at 15 million operations at no load, and it supports a phase-to-phase rated voltage (AC) of 690 V.
Schneider Electric
Quick Quote
LC1D40N7
Schneider Electric LC1D40N7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 60A under AC-1 conditions and 40A at 440Vac under AC-3 conditions. This contactor is suitable for DIN rail mounting and offers an IP20 degree of protection. The control voltage (AC) ranges from 332-456Vac at 50Hz and 353-456Vac at 60Hz, with a nominal control voltage of 415Vac. The rated operating voltage (Ue) is up to 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac under AC-3 conditions. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, according to UL/CSA standards. The mechanical durability of the LC1D40N7, at no load, is rated at 15,000,000 operations, and its phase-to-phase rated voltage (AC) is 690 V.
Schneider Electric
Quick Quote
LC1D40FD
Schneider Electric LC1D40FD is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 60A (AC-1) and 40A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The degree of protection provided is IP20, and it operates with a control voltage (DC) range of 82.5-137.5Vdc (110Vdc nom.; 0.75...1.25 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor supports a rated active power of 11kW (220-230Vac; AC-3) up to 30kW (660-690Vac; AC-3), and it also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) ranges from 3HP at 115Vac to 30HP at 575-600Vac, suitable for various applications. It boasts a mechanical durability of 15 million operations at no load, and the rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D40D7
Schneider Electric LC1D40D7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3NO). It has a rated current of 60A for AC-1 and 40A for AC-3 at 440Vac. This contactor is suitable for DIN rail mounting and offers an IP20 degree of protection. The control voltage (AC) ranges from 33.6-46.2Vac at 50Hz and 35.7-46.2Vac at 60Hz, with a nominal voltage of 42Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both types being instantaneous. The rated impulse voltage (Uimp) is 6 kV. It supports rated active power up to 30kW for AC-3 at 660-690Vac and rated power in horsepower varies from 3HP to 30HP across different voltages and phases, adhering to UL/CSA standards. The mechanical durability of this contactor is rated at 15 million operations at no load, with a phase-to-phase rated voltage of 690 V.
Schneider Electric
Quick Quote
LC1D40AYC7
Schneider Electric LC1D40AYC7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and screw connections. This 3-pole (3P; 3NO) contactor supports a rated current of 60A (AC-1) and 40A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. It has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 528-726Vac (660Vac nominal; 50Hz; 0.8...1.1 x Uc) to 561-726Vac (660Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) spans from 11kW (220-230Vac; AC-3) to 30kW (660-690Vac; AC-3). The rated power (HP) ranges from 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). This contactor is designed for mechanical durability of 6 000 000 operations and electrical durability of 1 500 000 operations with load, with a phase-to-phase rated voltage (AC) of 690 V.
Schneider Electric
Quick Quote
Items per page: