About the manufacturer: Schneider Electric is one of the manufacturers that offers Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1D115BD Schneider Electric price in the box on the right side or send a quick quote.

LC1D115BD Product Details

  • Motor Power Kw
    30 kW 220...230 V AC 50/60 Hz AC-3) 55 kW 380...400 V AC 50/60 Hz AC-3) 59 kW 415...440 V AC 50/60 Hz AC-3) 75 kW 500 V AC 50/60 Hz AC-3) 80 kW 660...690 V AC 50/60 Hz AC-3) 65 kW 1000 V AC 50/60 Hz AC-3) 18.5 kW 400 V AC 50/
  • [Icw] Rated Short-Time Withstand Current
    250 A 104 °F (40 °C) - 10 min power circuit 550 A 104 °F (40 °C) - 1 min power circuit 950 A 104 °F (40 °C) - 10 s power circuit 1100 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling ci
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • Motor Power HP (UL / CSA)
    30 hp 200/208 V at AC 50/60 Hz for 3 phase 40 hp 230/240 V at AC 50/60 Hz for 3 phase 75 hp 460/480 V at AC 50/60 Hz for 3 phase 100 hp 575/600 V at AC 50/60 Hz for 3 phase
  • Connections - Terminals
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)fl
  • Control Circuit Voltage Limits
    0.75...1.2 Uc -40…131 °F (-40…55 °C) operational DC 0.15...0.4 Uc -40…158 °F (-40…70 °C) drop-out DC 1...1.2 Uc 131…158 °F (55…70 °C) operational DC
  • Irms Rated Making Capacity
    1260 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
  • Utilisation Category
    AC-4 AC-1 AC-3
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Mounting Support
    Plate Rail
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Power Dissipation Per Pole
    24 W AC-1 7.9 W AC-3
  • Operating Time
    20...35 ms closing 40...75 ms opening
  • Contactor Application
    Resistive load Motor control
  • [Ie] Rated Operational Current
    200 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 115 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • Electrical Durability
    0.8 Mcycles 200 A AC-1 <= 440 V 0.95 Mcycles 115 A AC-3 <= 440 V
  • [Ue] Rated Operational Voltage
    Power circuit <= 1000 V AC 25...400 Hz Power circuit <= 300 V DC
  • Product Certifications
    CCC UL BV CSA GL GOST DNV LROS (Lloyds register of shipping) RINA UKCA
  • Tightening Torque
    Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
  • Associated Fuse Rating
    250 A gG <= 690 V type 1 power circuit 200 A gG <= 690 V type 2 power circuit 10 A gG signalling circuit
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Minimum Switching Voltage
    17 V signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Time Constant
    25 ms
  • Hold-In Power Consumption In W
    2.4…5.1 W 68 °F (20 °C)
  • Maximum Operating Rate
    1200 cyc/h 140 °F (60 °C)
  • Coil Technology
    With integral suppression device
  • Inrush Power In W
    270…365 W 68 °F (20 °C))
  • Signalling Circuit Frequency
    25...400 Hz
  • Mechanical Durability
    8 Mcycles
  • Rated Breaking Capacity
    1100 A 440 V power circuit IEC 60947
  • Average Impedance
    0.6 mOhm - Ith 200 A 50 Hz power circuit
  • Front Cover
    With
  • [Ith] Conventional Free Air Thermal Current
    200 A 140 °F (60 °C) power circuit
  • [Uc] Control Circuit Voltage
    24 V DC
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Control Circuit Type
    DC standard
  • Overvoltage Category
    III
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Product Name
    TeSys D
  • Device Short Name
    LC1D
  • Product Or Component Type
    Contactor
  • Range
    TeSys

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


This item can ship within 3 days!

1-year warranty

$516.35

LC1D115BD

Stock:

4

Select Qty:

$516.35

$516.35 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo