Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3969918 Phoenix Contact Terminal Blocks

Phoenix Contact 3969918 Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Ring cable lug, number of connections: 6, number of positions: 3, width: 57.1 mm, height: 70.1 mm, color: gray, mounting type: Wall mounting
Phoenix Contact

Part#:3969918

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Ring cable lug, number of connections: 6, number of positions: 3, width: 57.1 mm, height: 70.1 mm, color: gray, mounting type: Wall mounting

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3969918 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Maximum power dissipation for nominal condition
    1.31 W
  • Nominal voltage UN
    400 V AC/DC
  • Result of surge voltage test
    Test passed
  • Result of tight fit on support
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Short-time current
    1250 A
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Shock test result
    Test passed
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Number of positions
    3
  • Number of levels
    1
  • Number of connections
    6
  • Nominal cross section
    6 mm²
  • Maximum load current
    30 A (with 10 mm² conductor cross section)
  • Note regarding shock protection
    Back of hand protection without cable lug, as well as with insulated and uninsulated cable lugs with shrink sleeve with tightened clamping screw.
  • Result of voltage-drop test
    Test passed
  • Result of temperature-rise test
    Test passed
  • Result of thermal test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Acceleration
    30g
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Length
    81 mm
  • Connection
    1 level
  • Tightening torque, min
    1.5 Nm
  • Max. AWG conductor cross section, flexible
    8
  • Min. AWG conductor cross section, flexible
    24
  • Max. cross section for cable lug connection
    10 mm²
  • Min. tightening torque of the mounting screw:
    0.8 Nm
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 4.1
    27141100
  • ETIM 7.0
    EC000902
  • UNSPSC 6.01
    30211811
  • Potentials
    3
  • Rated surge voltage
    4 kV
  • Terminal block mounting
    0.8 Nm ... 1 Nm
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Setpoint
    5 N
  • Conductor cross section short circuit testing
    4 mm²
  • Shock form
    Half-sine
  • Static insulating material application in cold
    -60 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    57.1 mm
  • Plate thickness
    1 mm ... 4 mm
  • Stripping length
    12 mm
  • Conductor cross section flexible max.
    10 mm²
  • ASD level
    6.12 (m/s2)2/Hz
  • 2 conductors with same cross section, solid min.
    0.5 mm²
  • Min. cross section for cable lug connection
    0.5 mm²
  • Bolt diameter
    4.1 mm
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 11.0
    27141126
  • ECLASS 5.1
    27141100
  • ECLASS 9.0
    27141126
  • UNSPSC 11
    39121410
  • UNSPSC 21.0
    39121410
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of power-frequency withstand voltage test
    Test passed
  • Note
    Test with 4 mm² / 500 A / 1 s includes test with 4 mm² / 480 A / 1 s in accordance with IEC 60947-7-1:2009-04.
  • Oscillation, broadband noise test result
    Test passed
  • ECLASS 4.0
    27141100
  • ECLASS 7.0
    27141126
  • ETIM 6.0
    EC000902
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Number of shocks per direction
    3
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Pitch
    8.2 mm
  • Screw thread
    No 8 UNC
  • 2 conductors with same cross section, stranded min.
    0.5 mm²
  • Color
    gray
  • Insulating material
    PA
  • Test surge voltage
    5 kV
  • Insulating material group
    I
  • Cable lug width, max.
    8 mm
  • Mounting type
    Wall mounting
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Flammability rating according to UL 94
    V0
  • Overvoltage category
    III
  • Open side panel
    No
  • Back of the hand protection
    guaranteed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Short circuit stability result
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test duration per axis
    5 h
  • Shock duration
    18 ms
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Tightening torque max
    1.8 Nm
  • Connection in acc. with standard
    IEC 60947-7-1
  • Cable lug connection according to standard
    DIN 46237:1970-07
  • Hole diameter, min.
    4.3 mm
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ECLASS 10.0.1
    27141126
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 6.0
    27141100
  • UNSPSC 7.0901
    39121410
  • UNSPSC 12.01
    39121410
  • UNSPSC 20.0
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height
    70.1 mm
  • Connection method
    Ring cable lug
  • Conductor cross section flexible min.
    0.5 mm²
  • 2 conductors with same cross section, solid max.
    6 mm²
  • 2 conductors with same cross section, stranded max.
    6 mm²
  • Internal cylindrical gage
    A5
  • Max. tightening torque of the mounting screw:
    1 Nm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141100
  • ETIM 4.0
    EC000897
  • UNSPSC 13.2
    39121410
  • UNSPSC 18.0
    39121410
  • UNSPSC 19.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo