3969916 Phoenix Contact Terminal Blocks

Phoenix Contact 3969916 Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Ring cable lug, number of connections: 26, number of positions: 13, width: 138.6 mm, height: 70.1 mm, color: gray, mounting type: Wall mounting
Phoenix Contact

Part#:3969916

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 2

Nov 22, 2024

Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Ring cable lug, number of connections: 26, number of positions: 13, width: 138.6 mm, height: 70.1 mm, color: gray, mounting type: Wall mounting

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3969916 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of positions
    13
  • Potentials
    13
  • Rated surge voltage
    4 kV
  • Terminal block mounting
    0.8 Nm ... 1 Nm
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of tight fit on support
    Test passed
  • Short circuit stability result
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock duration
    18 ms
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Number of levels
    1
  • Test surge voltage
    5 kV
  • Flammability rating according to UL 94
    V0
  • Note regarding shock protection
    Back of hand protection without cable lug, as well as with insulated and uninsulated cable lugs with shrink sleeve with tightened clamping screw.
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Result of thermal test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Acceleration
    30g
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Connection
    1 level
  • Insulating material
    PA
  • Maximum power dissipation for nominal condition
    1.31 W
  • Overvoltage category
    III
  • Result of surge voltage test
    Test passed
  • Setpoint
    5 N
  • Short-time current
    1250 A
  • Conductor cross section short circuit testing
    4 mm²
  • Test duration per axis
    5 h
  • Shock form
    Half-sine
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height
    70.1 mm
  • Conductor cross section flexible min.
    0.5 mm²
  • 2 conductors with same cross section, solid max.
    6 mm²
  • Nominal cross section
    6 mm²
  • Color
    gray
  • Insulating material group
    I
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Open side panel
    No
  • Result of temperature-rise test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Shock test result
    Test passed
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Plate thickness
    1 mm ... 4 mm
  • Connection method
    Ring cable lug
  • Tightening torque max
    1.8 Nm
  • Back of the hand protection
    guaranteed
  • Result of voltage-drop test
    Test passed
  • Note
    Test with 4 mm² / 500 A / 1 s includes test with 4 mm² / 480 A / 1 s in accordance with IEC 60947-7-1:2009-04.
  • Oscillation, broadband noise test result
    Test passed
  • Cable lug connection according to standard
    DIN 46237:1970-07
  • Cable lug width, max.
    8 mm
  • ASD level
    6.12 (m/s2)2/Hz
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of connections
    26
  • Nominal voltage UN
    400 V AC/DC
  • Maximum load current
    30 A (with 10 mm² conductor cross section)
  • Number of shocks per direction
    3
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Length
    81 mm
  • Pitch
    8.2 mm
  • Screw thread
    No 8 UNC
  • Max. AWG conductor cross section, flexible
    8
  • Width
    138.6 mm
  • Tightening torque, min
    1.5 Nm
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Conductor cross section flexible max.
    10 mm²
  • Connection in acc. with standard
    IEC 60947-7-1
  • 2 conductors with same cross section, solid min.
    0.5 mm²
  • Max. tightening torque of the mounting screw:
    1 Nm
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27141100
  • ETIM 6.0
    EC000902
  • UNSPSC 12.01
    39121410
  • UNSPSC 20.0
    39121410
  • Min. AWG conductor cross section, flexible
    24
  • Internal cylindrical gage
    A5
  • Mounting type
    Wall mounting
  • ECLASS 10.0.1
    27141126
  • ECLASS 5.0
    27141100
  • ETIM 7.0
    EC000902
  • UNSPSC 11
    39121410
  • UNSPSC 18.0
    39121410
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141126
  • ECLASS 9.0
    27141126
  • ECLASS 7.0
    27141126
  • UNSPSC 13.2
    39121410
  • Bolt diameter
    4.1 mm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 6.0
    27141100
  • ECLASS 5.1
    27141100
  • UNSPSC 6.01
    30211811
  • UNSPSC 19.0
    39121410
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 4.1
    27141100
  • ETIM 4.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 21.0
    39121410
  • 2 conductors with same cross section, stranded min.
    0.5 mm²
  • Hole diameter, min.
    4.3 mm
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Stripping length
    12 mm
  • Min. cross section for cable lug connection
    0.5 mm²
  • 2 conductors with same cross section, stranded max.
    6 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • Max. cross section for cable lug connection
    10 mm²
  • Min. tightening torque of the mounting screw:
    0.8 Nm

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$875.08

Stock:

2

Select Qty:

$875.08

$875.08 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo