Distribution block, bridged internally, nom. voltage: 450 V, nominal current: 32 A, connection method: Push-in connection, Push-in connection, number of connections: 13, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 46.3 mm, height: 22.7 mm, color:
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3274010 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of connections 13
- Overvoltage category III
- Maximum total current 63 A
- Finger protection guaranteed
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Shock test result Test passed
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 11.0 27141120
- ECLASS 6.0 27141100
- ETIM 7.0 EC000897
- UNSPSC 11 39121410
- Insulating material PA
- Rated surge voltage 6 kV
- Open side panel No
- Nominal voltage UN 450 V
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- Acceleration 30g
- Shock form Half-sine
- Surface flammability NFPA 130 (ASTM E 162) passed
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.5 mm²
- Min. AWG conductor cross section, flexible 20
- Ambient temperature (actuation) -5 °C ... 70 °C
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 4.0 27141121
- ECLASS 7.0 27141120
- ETIM 6.0 EC000897
- UNSPSC 6.01 30211811
- UNSPSC 19.0 39121410
- Nominal cross section feed-in 10 mm²
- Degree of pollution 3
- Nominal current IN 57 A
- Conductor cross section flexible, with ferrule without plastic sleeve max. 10 mm²
- Connection cross sections directly pluggable 1 mm² 16 mm²
- Internal cylindrical gage A3
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 5.0 27141120
- ETIM 3.0 EC000897
- UNSPSC 18.0 39121410
- UNSPSC 20.0 39121410
- Number of levels 1
- Nominal cross section 4 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 10 mm²
- Value 1 mm²
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 4.1 27141121
- ECLASS 5.1 27141120
- UNSPSC 7.0901 39121410
- UNSPSC 13.2 39121410
- Potentials 1
- Color gray
- Maximum load current 57 A
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.5 mm²
- Connection Feed-in stage
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- ECLASS 10.0.1 27141120
- ECLASS 9.0 27141120
- ETIM 4.0 EC000897
- UNSPSC 12.01 39121410
- UNSPSC 21.0 39121410
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test spectrum Service life test category 2, bogie-mounted
- Number of shocks per direction 3
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Connection method Push-in connection
- Conductor cross section solid max. 16 mm²
- Conductor cross section AWG max. 6
- Flammability rating according to UL 94 V0
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Back of the hand protection guaranteed
- Oscillation, broadband noise test result Test passed
- Test duration per axis 5 h
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Connection in acc. with standard IEC 60998-2-2
- Conductor cross section flexible min. 0.5 mm²
- Max. AWG conductor cross section, flexible 8
- Result of thermal test Test passed
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Shock duration 18 ms
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Static insulating material application in cold -60 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Length 28.6 mm
- Stripping length 12 mm ... 14 mm
- Conductor cross section flexible max. 10 mm²
- Insulating material group I
- ASD level 6.12 (m/s2)2/Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2018-05
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Width 46.3 mm
- Height 22.7 mm
- Conductor cross section solid min. 1 mm²
- Conductor cross section AWG min. 20
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$8.73
Stock:
6
Select Qty:
$8.73
$8.73 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨