Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3247051 Phoenix Contact Terminal Blocks

Phoenix Contact 3247051 High-current terminal block, nom. voltage: 1000 V, nominal current: 192 A, connection method: Screw connection, number of connections: 2, number of positions: 1, cross section: 16 mm² - 95 mm², AWG: 4 - 3/0, width: 20.3 mm, height: 80 mm, color: gray, mou
Phoenix Contact

Part#:3247051

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 5

May 11, 2024

About the product: High-current terminal block, nom. voltage: 1000 V, nominal current: 192 A, connection method: Screw connection, number of connections: 2, number of positions: 1, cross section: 16 mm² - 95 mm², AWG: 4 - 3/0, width: 20.3 mm, height: 80 mm, color: gray, mou

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3247051 Phoenix Contact price in the box on the right side or send a quick quote.

3247051 Product Details

  • Shock form
    Half-sine
  • Number of levels
    1
  • Color
    gray
  • Insulating material
    PA
  • Overvoltage category
    III
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Back of the hand protection
    guaranteed
  • Power frequency withstand voltage setpoint
    2.2 kV
  • Result of flexion and pull-out test
    Test passed
  • Short circuit stability result
    Test passed
  • Result of thermal test
    Test passed
  • Acceleration
    5g
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Number of connections
    2
  • Area of application
    Railway industry
  • Insulating material group
    I
  • Nominal current IN
    192 A
  • Nominal voltage UN
    1000 V
  • Finger protection
    guaranteed
  • Tensile test result
    Test passed
  • Conductor cross section short circuit testing
    70 mm²
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • ASD level
    1.857 (m/s2)2/Hz
  • Shock test result
    Test passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height
    80 mm
  • Tightening torque max
    10 Nm
  • Conductor cross section solid min.
    16 mm²
  • Conductor cross section flexible min.
    25 mm²
  • Max. AWG conductor cross section, flexible
    2/0
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    16 mm²
  • Internal cylindrical gage
    A11
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • ECLASS 6.0
    27141100
  • ECLASS 9.0
    27141120
  • UNSPSC 11
    39121410
  • UNSPSC 13.2
    39121410
  • Nominal cross section
    70 mm²
  • Rated surge voltage
    8 kV
  • Maximum power dissipation for nominal condition
    6.27 W
  • Open side panel
    No
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test conductor cross section/weight
    25 mm² / 4.5 kg
  • Result of tight fit on support
    Test passed
  • Result of temperature-rise test
    Test passed
  • Short-time current
    8.4 kA
  • Test spectrum
    Service life test category 1, class B, body mounted
  • Test duration per axis
    5 h
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Width
    20.3 mm
  • Screw thread
    M8
  • Connection method
    Screw connection
  • Conductor cross section AWG min.
    4
  • Min. AWG conductor cross section, flexible
    3
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    16 mm²
  • 2 conductors with same cross section, stranded min.
    16 mm²
  • 2 conductors with same cross section, stranded max.
    25 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 10.0.1
    27141120
  • ECLASS 5.0
    27141100
  • ECLASS 5.1
    27141100
  • UNSPSC 7.0901
    39121410
  • UNSPSC 18.0
    39121410
  • UNSPSC 21.0
    39121410
  • Number of positions
    1
  • Potentials
    1
  • Flammability rating according to UL 94
    V0
  • Degree of pollution
    3
  • Maximum load current
    192 A (in case of a 70 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
  • Result of surge voltage test
    Test passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Setpoint
    10 N
  • Result of voltage-drop test
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of shocks per direction
    3
  • Shock duration
    30 ms
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Length
    103.4 mm
  • Note
    Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    70 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    70 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    16 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    25 mm²
  • 2 conductors with same cross section, solid max.
    25 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 11.0
    27141120
  • ETIM 6.0
    EC000897
  • ETIM 4.0
    EC000897
  • UNSPSC 19.0
    39121410
  • Tightening torque, min
    8 Nm
  • Conductor cross section AWG max.
    3/0
  • Conductor cross section solid max.
    95 mm²
  • Conductor cross section flexible max.
    70 mm²
  • 2 conductors with same cross section, solid min.
    16 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 4.0
    27141100
  • ECLASS 7.0
    27141120
  • ETIM 7.0
    EC000897
  • UNSPSC 12.01
    39121410
  • UNSPSC 6.01
    30211811
  • UNSPSC 20.0
    39121410
  • Stripping length
    24 mm

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$35.61

3247051

Stock:

5

Select Qty:

$35.61

$35.61 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo