Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3210230 Phoenix Contact Terminal Blocks

Phoenix Contact 3210230 Disconnect terminal block, with isolating plug, nom. voltage: 400 V, nominal current: 16 A, connection method: Push-in connection, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, length: 92.4 mm, width: 5.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3210230

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 95

Nov 26, 2024

Disconnect terminal block, with isolating plug, nom. voltage: 400 V, nominal current: 16 A, connection method: Push-in connection, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, length: 92.4 mm, width: 5.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3210230 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of levels
    2
  • Color
    gray
  • Degree of pollution
    3
  • Overvoltage category
    III
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Bending test rotation speed
    10 rpm
  • Bending test turns
    135
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Short-time current
    0.3 kA
  • Oscillation, broadband noise test result
    Test passed
  • Acceleration
    30g
  • Shock test result
    Test passed
  • Number of shocks per direction
    3
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Stripping length
    8 mm ... 10 mm
  • Conductor cross section AWG min.
    26
  • Min. AWG conductor cross section, flexible
    26
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Internal cylindrical gage
    A3
  • ECLASS 10.0.1
    27141120
  • Potentials
    2
  • Rated surge voltage
    6 kV
  • Nominal current IN
    16 A
  • Result of surge voltage test
    Test passed
  • Tight fit on carrier
    NS 35
  • Result of temperature-rise test
    Test passed
  • Conductor cross section short circuit testing
    2.5 mm²
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock duration
    18 ms
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Width
    5.2 mm
  • Height NS 35/7,5
    47.4 mm
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section AWG max.
    12
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    0.5 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 7.0
    27141120
  • UNSPSC 7.0901
    39121410
  • UNSPSC 13.2
    39121410
  • UNSPSC 19.0
    39121410
  • Flammability rating according to UL 94
    V0
  • Insulating material group
    I
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Finger protection
    guaranteed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Setpoint
    1 N
  • Result of aging test
    Test passed
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test duration per axis
    5 h
  • Shock form
    Half-sine
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • End cover width
    0.8 mm
  • Height NS 35/15
    54.9 mm
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • Connection cross sections directly pluggable
    0.34 mm² 4 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 125°C)
  • ECLASS 4.0
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 6.0
    EC000897
  • ETIM 7.0
    EC000897
  • UNSPSC 21.0
    39121410
  • Number of connections
    4
  • Insulating material
    PA
  • Maximum load current
    16 A (with 4 mm² conductor cross section)
  • Open side panel
    Yes
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Result of voltage-drop test
    Test passed
  • Result of thermal test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Length
    92.4 mm
  • Connection
    1st and 2nd level
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section flexible max.
    2.5 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 11.0
    27141120
  • ECLASS 5.0
    27141100
  • ECLASS 4.1
    27141100
  • UNSPSC 6.01
    30211811
  • UNSPSC 11
    39121410
  • UNSPSC 18.0
    39121410
  • Nominal cross section
    2.5 mm²
  • Maximum power dissipation for nominal condition
    0.77 W (the value is multiplied when connecting multiple levels)
  • Nominal voltage UN
    400 V
  • Back of the hand protection
    guaranteed
  • Result of flexion and pull-out test
    Test passed
  • Result of tight fit on support
    Test passed
  • Short circuit stability result
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height
    45.8 mm
  • Connection method
    Push-in connection
  • Conductor cross section solid max.
    4 mm²
  • Max. AWG conductor cross section, flexible
    14
  • ECLASS 5.1
    27141100
  • ECLASS 9.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 20.0
    39121410
  • UNSPSC 12.01
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$14.22

Stock:

95

Select Qty:

$14.22

$14.22 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo