Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3209549 Phoenix Contact Terminal Blocks

Phoenix Contact 3209549 Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 3, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 35.2 mm, color: gray, mounting type: NS 35/7,5,
Phoenix Contact

Part#:3209549

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 79197

Nov 21, 2024

Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 3, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 35.2 mm, color: gray, mounting type: NS 35/7,5,

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3209549 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Maximum load current
    28 A (with 4 mm² conductor cross section, rigid)
  • Setpoint
    1 N
  • Result of temperature-rise test
    Test passed
  • Tensile test result
    Test passed
  • ECLASS 5.1
    27141100
  • Number of levels
    1
  • Color
    gray
  • Overvoltage category
    III
  • Maximum power dissipation for nominal condition
    0.77 W
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Bending test turns
    135
  • Tight fit on carrier
    NS 35
  • Note
    The max. load current must not be exceeded by the total current of all connected conductors.
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Acceleration
    30g
  • Shock form
    Half-sine
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height
    35.2 mm
  • Connection in acc. with standard
    CSA
  • Conductor cross section solid min.
    0.34 mm²
  • Min. AWG conductor cross section, flexible
    26
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 4.1
    27141100
  • Short-time current
    0.48 kA
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Height NS 35/7,5
    36.5 mm
  • Connection method
    Push-in connection
  • Conductor cross section AWG max.
    12
  • Max. AWG conductor cross section, flexible
    14
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    0.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Shock test result
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/15
    44 mm
  • Conductor cross section solid max.
    4 mm²
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Connection cross sections directly pluggable
    0.34 mm² 4 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • ETIM 3.0
    EC000897
  • UNSPSC 6.01
    30211811
  • Result of thermal test
    Test passed
  • End cover width
    2.2 mm
  • Stripping length
    8 mm ... 10 mm
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • ECLASS 10.0.1
    27141120
  • Conductor cross section short circuit testing
    4 mm²
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test duration per axis
    5 h
  • Shock duration
    18 ms
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Result of aging test
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Number of shocks per direction
    3
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Width
    5.2 mm
  • Length
    60.5 mm
  • Connection
    1 level
  • Conductor cross section AWG min.
    26
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Internal cylindrical gage
    A3
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 6.0
    27141100
  • ECLASS 7.0
    27141120
  • Short circuit stability result
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Number of connections
    3
  • Insulating material
    PA
  • Degree of pollution
    3
  • Nominal voltage UN
    800 V
  • Result of flexion and pull-out test
    Test passed
  • Result of tight fit on support
    Test passed
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 9.0
    27141120
  • ETIM 2.0
    EC000897
  • UNSPSC 19.0
    39121410
  • UNSPSC 21.0
    39121410
  • Area of application
    Railway industry
  • Insulating material group
    I
  • Back of the hand protection
    guaranteed
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • UNSPSC 12.01
    39121410
  • UNSPSC 11
    39121410
  • ETIM 4.0
    EC000897
  • ETIM 6.0
    EC000897
  • UNSPSC 20.0
    39121410
  • UNSPSC 18.0
    39121410
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • ETIM 7.0
    EC000897
  • Potentials
    1
  • Flammability rating according to UL 94
    V0
  • Nominal current IN
    24 A (with 2.5 mm² conductor connection cross section)
  • Finger protection
    guaranteed
  • Rated surge voltage
    8 kV
  • Result of surge voltage test
    Test passed
  • Nominal cross section
    2.5 mm²
  • Bending test rotation speed
    10 rpm
  • ECLASS 4.0
    27141100
  • ECLASS 5.0
    27141100
  • UNSPSC 13.2
    39121410
  • UNSPSC 7.0901
    39121410
  • Power frequency withstand voltage setpoint
    2 kV
  • Result of voltage-drop test
    Test passed
  • Open side panel
    Yes

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$2.37

Stock:

79,197

Select Qty:

$2.37

$2.37 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo