3209510 Phoenix Contact Terminal Blocks

Phoenix Contact 3209510 Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 2, number of positions: 1, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 35.3 mm, color: gray, m
Phoenix Contact

Part#:3209510

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 51259

Nov 21, 2024

Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 2, number of positions: 1, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 35.3 mm, color: gray, m

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3209510 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Result of tight fit on support
    Test passed
  • Tight fit on carrier
    NS 35/7.5
  • Nominal current IN
    24 A (at 2.5 mm²)
  • Result of surge voltage test
    Test passed
  • Acceleration
    30g
  • Shock form
    Half-sine
  • Static insulating material application in cold
    -60 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Nominal voltage UN
    800 V
  • Result of flexion and pull-out test
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Shock test result
    Test passed
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2018-05
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/7,5
    36.5 mm
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Finger protection
    guaranteed
  • Setpoint
    1 N
  • Result of aging test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • ASD level
    6.12 (m/s2)2/Hz
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Length
    48.6 mm
  • Maximum power dissipation for nominal condition
    0.77 W
  • Surge voltage test setpoint
    9.8 kV
  • Bending test turns
    135
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test duration per axis
    5 h
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Stripping length
    8 mm ... 10 mm
  • Connection in acc. with standard
    CSA
  • Result of thermal test
    Test passed
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Number of shocks per direction
    3
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Connection method
    Push-in connection
  • ECLASS 6.0
    27141100
  • ETIM 3.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • Power frequency withstand voltage setpoint
    2 kV
  • Requirements, voltage drop
    ≤ 3.2 mV
  • Conductor cross section solid max.
    4 mm²
  • Conductor cross section flexible min.
    0.14 mm²
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Short-time current
    0.48 kA
  • Result of temperature-rise test
    Test passed
  • Connection
    1 level
  • Min. AWG conductor cross section, flexible
    26
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • Result of voltage-drop test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Height NS 35/15
    44 mm
  • Conductor cross section solid min.
    0.14 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • Connection cross sections directly pluggable
    0.34 mm² 4 mm²
  • ECLASS 4.0
    27141100
  • ECLASS 5.1
    27141100
  • ECLASS 7.0
    27141120
  • UNSPSC 13.2
    39121410
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Conductor cross section short circuit testing
    4 mm²
  • Short circuit stability result
    Test passed
  • Conductor cross section AWG max.
    12
  • Conductor cross section flexible max.
    2.5 mm²
  • Internal cylindrical gage
    A3
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 11.0
    27141120
  • ECLASS 10.0.1
    27141120
  • ETIM 4.0
    EC000897
  • ETIM 7.0
    EC000897
  • UNSPSC 11
    39121410
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Width
    5.2 mm
  • Height
    35.3 mm
  • Conductor cross section AWG min.
    26
  • Max. AWG conductor cross section, flexible
    14
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    0.5 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141100
  • UNSPSC 6.01
    30211811
  • UNSPSC 18.0
    39121410
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ETIM 2.0
    EC000897
  • ETIM 6.0
    EC000897
  • UNSPSC 21.0
    39121410
  • ECLASS 4.1
    27141100
  • ECLASS 9.0
    27141120
  • UNSPSC 12.01
    39121410
  • UNSPSC 19.0
    39121410
  • UNSPSC 20.0
    39121410
  • Number of levels
    1
  • Color
    gray
  • Degree of pollution
    3
  • Number of connections
    2
  • Insulating material
    PA
  • Insulating material group
    I
  • Potentials
    1
  • Area of application
    Railway industry
  • Maximum load current
    28 A (with 4 mm² conductor cross section, rigid)
  • Back of the hand protection
    guaranteed
  • Nominal cross section
    2.5 mm²
  • Overvoltage category
    III
  • Open side panel
    Yes
  • Rated surge voltage
    8 kV
  • Shock duration
    18 ms
  • Number of positions
    1
  • Flammability rating according to UL 94
    V0

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$2.05

Stock:

51,259

Select Qty:

$2.05

$2.05 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo