3209578 Phoenix Contact Terminal Blocks

Phoenix Contact 3209578 Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 4, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 35.3 mm, color: gray, mounting type: NS 35/7,5,
Phoenix Contact

Part#:3209578

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 20306

Nov 21, 2024

Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 4, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 35.3 mm, color: gray, mounting type: NS 35/7,5,

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3209578 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Tensile test result
    Test passed
  • Test duration per axis
    5 h
  • Stripping length
    8 mm ... 10 mm
  • Conductor cross section AWG min.
    26
  • Min. AWG conductor cross section, flexible
    26
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of flexion and pull-out test
    Test passed
  • Result of voltage-drop test
    Test passed
  • Short circuit stability result
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Height
    35.3 mm
  • Connection method
    Push-in connection
  • ASD level
    6.12 (m/s2)2/Hz
  • Number of shocks per direction
    3
  • End cover width
    2.2 mm
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Connection in acc. with standard
    CSA
  • Conductor cross section AWG max.
    12
  • Internal cylindrical gage
    A3
  • Number of levels
    1
  • Area of application
    Railway industry
  • Power frequency withstand voltage setpoint
    2 kV
  • Overvoltage category
    III
  • Nominal current IN
    24 A (with 2.5 mm² conductor connection cross section)
  • Back of the hand protection
    guaranteed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Result of temperature-rise test
    Test passed
  • Short-time current
    0.48 kA
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Shock test result
    Test passed
  • Rated surge voltage
    8 kV
  • Insulating material
    PA
  • Insulating material group
    I
  • Open side panel
    Yes
  • Result of surge voltage test
    Test passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Bending test turns
    135
  • Setpoint
    1 N
  • Number of connections
    4
  • Conductor cross section short circuit testing
    4 mm²
  • Result of aging test
    Test passed
  • Color
    gray
  • Flammability rating according to UL 94
    V0
  • Degree of pollution
    3
  • Finger protection
    guaranteed
  • Potentials
    1
  • Nominal cross section
    2.5 mm²
  • Nominal voltage UN
    800 V
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 6.0
    27141100
  • ETIM 2.0
    EC000897
  • UNSPSC 11
    39121410
  • UNSPSC 12.01
    39121410
  • UNSPSC 20.0
    39121410
  • Tight fit on carrier
    NS 35
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    0.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 4.0
    27141100
  • ECLASS 4.1
    27141100
  • ETIM 3.0
    EC000897
  • ETIM 7.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 19.0
    39121410
  • Max. AWG conductor cross section, flexible
    14
  • Connection cross sections directly pluggable
    0.34 mm² 4 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 10.0.1
    27141120
  • ECLASS 5.0
    27141100
  • ECLASS 7.0
    27141120
  • ETIM 6.0
    EC000897
  • UNSPSC 6.01
    30211811
  • UNSPSC 13.2
    39121410
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • ECLASS 5.1
    27141100
  • ECLASS 9.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 18.0
    39121410
  • UNSPSC 21.0
    39121410
  • Maximum load current
    28 A (with 4 mm² conductor cross section, rigid)
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2018-05
  • Static insulating material application in cold
    -60 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Connection
    1 level
  • Conductor cross section solid max.
    4 mm²
  • Maximum power dissipation for nominal condition
    0.77 W
  • Result of power-frequency withstand voltage test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Result of thermal test
    Test passed
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Shock duration
    30 ms
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Result of tight fit on support
    Test passed
  • Acceleration
    5g
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/7,5
    36.8 mm
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock form
    Half-sine
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Width
    5.2 mm
  • Height NS 35/15
    44.3 mm
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section flexible min.
    0.14 mm²
  • Bending test rotation speed
    10 rpm
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Length
    72.2 mm

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$1.66

Stock:

20,306

Select Qty:

$1.66

$1.66 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo