3069663 Phoenix Contact Terminal Blocks

Phoenix Contact 3069663 Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Screw connection, number of connections: 28, number of positions: 14, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 147.6 mm, height: 56.5 mm, color: gray, mounting type: Wall mount
Phoenix Contact

Part#:3069663

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Screw connection, number of connections: 28, number of positions: 14, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 147.6 mm, height: 56.5 mm, color: gray, mounting type: Wall mount

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3069663 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of levels
    1
  • Insulating material
    PA
  • Overvoltage category
    III
  • Terminal block mounting
    0.8 Nm ... 1 Nm
  • Bending test turns
    135
  • Result of temperature-rise test
    Test passed
  • Nominal cross section
    6 mm²
  • Rated surge voltage
    4 kV
  • Maximum power dissipation for nominal condition
    1.31 W
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Flammability rating according to UL 94
    V0
  • Maximum load current
    30 A (with 10 mm² conductor cross section)
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Number of connections
    28
  • Color
    gray
  • Test surge voltage
    5 kV
  • Nominal voltage UN
    400 V AC/DC
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Setpoint
    5 N
  • Short-time current
    500 A
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Oscillation, broadband noise test result
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock duration
    18 ms
  • Number of positions
    14
  • Potentials
    14
  • Insulating material group
    I
  • Open side panel
    No
  • Result of surge voltage test
    Test passed
  • Tensile test result
    Test passed
  • Result of tight fit on support
    Test passed
  • Note
    25 pos.
  • Result of aging test
    Test passed
  • Test duration per axis
    5 h
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Short circuit stability result
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Shock form
    Half-sine
  • Static insulating material application in cold
    -60 °C
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Shock test result
    Test passed
  • Number of shocks per direction
    3
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • Result of voltage-drop test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Stripping length
    12 mm
  • Connection
    1 level
  • Tightening torque, min
    1.5 Nm
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Height
    56.5 mm
  • Width
    147.6 mm
  • REACh SVHC
    Lead 7439-92-1
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Length
    81 mm
  • Conductor cross section solid min.
    0.2 mm²
  • Internal cylindrical gage
    A5
  • Connection method
    Screw connection
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Result of thermal test
    Test passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Plate thickness
    1 mm ... 4 mm
  • Screw thread
    M4
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • Min. tightening torque of the mounting screw:
    0.8 Nm
  • Conductor cross section short circuit testing
    4 mm²
  • Acceleration
    30g
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Pitch
    8.2 mm
  • Tightening torque max
    1.8 Nm
  • Conductor cross section flexible max.
    10 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Max. tightening torque of the mounting screw:
    1 Nm
  • UNSPSC 6.01
    30211811
  • UNSPSC 19.0
    39121410
  • ECLASS 4.0
    27141100
  • UNSPSC 21.0
    39121410
  • ECLASS 11.0
    27141126
  • ECLASS 6.0
    27141100
  • Min. AWG conductor cross section, flexible
    24
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • UNSPSC 11
    39121410
  • UNSPSC 13.2
    39121410
  • ECLASS 5.1
    27141100
  • ETIM 4.0
    EC000897
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Mounting type
    Wall mounting
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • Max. AWG conductor cross section, flexible
    8
  • 2 conductors with same cross section, stranded max.
    2.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    2.5 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 7.0
    27141126
  • ETIM 6.0
    EC000902
  • ETIM 7.0
    EC000902
  • UNSPSC 18.0
    39121410
  • UNSPSC 20.0
    39121410
  • 2 conductors with same cross section, solid max.
    2.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ECLASS 4.1
    27141100
  • ECLASS 5.0
    27141100
  • ECLASS 9.0
    27141126
  • UNSPSC 7.0901
    39121410
  • UNSPSC 12.01
    39121410
  • 2 conductors with same cross section, stranded min.
    0.2 mm²
  • ECLASS 10.0.1
    27141126
  • Conductor cross section AWG max.
    8
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Conductor cross section solid max.
    10 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo