3002757 Phoenix Contact Terminal Blocks
Part#:3002757
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 3912
Nov 21, 2024
Distribution block, bridged internally, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 450 V, nominal current: 17.5 A, connection method: Push-in connection, number of
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3002757 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of connections 6
- Nominal cross section 1.5 mm²
- Rated surge voltage 6 kV
- Insulating material group I
- Nominal current IN 17.5 A
- UNSPSC 20.0 39121410
- Color gray
- ECLASS 4.0 27141120
- ECLASS 5.1 27141120
- ECLASS 9.0 27141120
- ETIM 2.0 EC000897
- ETIM 7.0 EC000897
- UNSPSC 11 39121410
- UNSPSC 21.0 39121410
- UNSPSC 19.0 39121410
- ECLASS 10.0.1 27141120
- ECLASS 5.0 27141120
- ETIM 4.0 EC000897
- ECLASS 7.0 27141120
- ETIM 6.0 EC000897
- UNSPSC 12.01 39121410
- UNSPSC 13.2 39121410
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 4.1 27141120
- ECLASS 11.0 27141120
- ECLASS 6.0 27141100
- ETIM 3.0 EC000897
- UNSPSC 6.01 30211811
- UNSPSC 7.0901 39121410
- UNSPSC 18.0 39121410
- Maximum load current 22 A
- Open side panel No
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- ASD level 6.12 (m/s2)2/Hz
- Shock duration 18 ms
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Number of levels 1
- Insulating material PA
- Maximum total current 26 A
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Oscillation, broadband noise test result Test passed
- Test duration per axis 5 h
- Number of shocks per direction 3
- Surface flammability NFPA 130 (ASTM E 162) passed
- Width 12.5 mm
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Stripping length 8 mm ... 10 mm
- Note Notes on operation The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories
- Overvoltage category III
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Shock test result Test passed
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Connection method Push-in connection
- Conductor cross section AWG max. 14
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
- Connection cross sections directly pluggable 0.34 mm² 2.5 mm² 26 14
- Ambient temperature (actuation) -5 °C ... 70 °C
- Potentials 1
- Flammability rating according to UL 94 V0
- Nominal voltage UN 450 V
- Finger protection guaranteed
- Acceleration 30g
- Shock form Half-sine
- Static insulating material application in cold -60 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Height 17.7 mm
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible max. 1.5 mm²
- Internal cylindrical gage A1 / B1
- Ambient temperature (assembly) -5 °C ... 70 °C
- Degree of pollution 3
- Maximum power dissipation for nominal condition 0.56 W
- Back of the hand protection guaranteed
- Test spectrum Service life test category 2, bogie-mounted
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2018-05
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Length 21.6 mm
- Conductor cross section solid min. 0.34 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 1.5 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Connection in acc. with standard IEC 60998-2-2
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG min. 26
- Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Min. AWG conductor cross section, flexible 24
- Max. AWG conductor cross section, flexible 14
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$2.11
Stock:
3,912
Select Qty:
$2.11
$2.11 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.