3001035 Phoenix Contact Terminal Blocks

Phoenix Contact 3001035 Feed-through terminal block, nom. voltage: 690 V, nominal current: 24 A, connection method: Screw connection, number of connections: 2, cross section: 0.2 mm² - 4 mm², AWG: 24 - 12, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3001035

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 6156

Apr 30, 2024

About the product: Feed-through terminal block, nom. voltage: 690 V, nominal current: 24 A, connection method: Screw connection, number of connections: 2, cross section: 0.2 mm² - 4 mm², AWG: 24 - 12, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3001035 Phoenix Contact price in the box on the right side or send a quick quote.

3001035 Product Details

  • Number of connections
    2
  • Color
    gray
  • Open side panel
    Yes
  • Finger protection
    guaranteed
  • Tensile test result
    Test passed
  • Nominal cross section
    2.5 mm²
  • Degree of pollution
    3
  • Back of the hand protection
    guaranteed
  • Result of surge voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Tight fit on carrier
    NS 32/NS 35
  • Result of temperature-rise test
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/7,5
    42 mm
  • Height NS 32
    47 mm
  • Conductor cross section solid max.
    4 mm²
  • Min. AWG conductor cross section, flexible
    24
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • 2 conductors with same cross section, solid max.
    1 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.0
    27141100
  • ECLASS 9.0
    27141120
  • ETIM 6.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 21.0
    39121410
  • Insulating material
    PA
  • Overvoltage category
    III
  • Nominal current IN
    24 A
  • Shock protection test specification
    IEC 60529:2001-02
  • Result of flexion and pull-out test
    Test passed
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Result of voltage-drop test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    6.2 mm
  • Height NS 35/15
    49.5 mm
  • Conductor cross section solid min.
    0.2 mm²
  • Tightening torque max
    0.8 Nm
  • Max. AWG conductor cross section, flexible
    14
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    1 mm²
  • 2 conductors with same cross section, stranded max.
    1 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27141100
  • ETIM 2.0
    EC000897
  • ETIM 4.0
    EC000897
  • UNSPSC 18.0
    39121410
  • UNSPSC 20.0
    39121410
  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Insulating material group
    I
  • Nominal voltage UN
    690 V
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of tight fit on support
    Test passed
  • Short-time current
    0.48 kA
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Length
    42.5 mm
  • Tightening torque, min
    0.6 Nm
  • Conductor cross section flexible max.
    2.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ECLASS 11.0
    27141120
  • ECLASS 4.1
    27141100
  • ETIM 3.0
    EC000897
  • UNSPSC 13.2
    39121410
  • Potentials
    1
  • Rated surge voltage
    8 kV
  • Maximum power dissipation for nominal condition
    0.77 W
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Bending test turns
    135
  • Setpoint
    1 N
  • Short circuit stability result
    Test passed
  • Result of thermal test
    Test passed
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • End cover width
    1.5 mm
  • Connection method
    Screw connection
  • Stripping length
    7 mm
  • Conductor cross section AWG max.
    12
  • Conductor cross section flexible min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Internal cylindrical gage
    A3
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27141100
  • ECLASS 7.0
    27141120
  • UNSPSC 6.01
    30211811
  • UNSPSC 12.01
    39121410
  • UNSPSC 19.0
    39121410
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Conductor cross section short circuit testing
    4 mm²
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Screw thread
    M3
  • Conductor cross section AWG min.
    30
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, stranded min.
    0.25 mm²
  • Connection in acc. with standard
    CSA
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 10.0.1
    27141120
  • ECLASS 6.0
    27141100
  • ETIM 7.0
    EC000897
  • UNSPSC 11
    39121410

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$3.57

3001035

Stock:

6156

Select Qty:

$3.57

$3.57 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo