2904371 Phoenix Contact AC/DC Power Supplies
Part#:2904371
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Checking verified in-stock parts...
About the product: Primary-switched UNO POWER power supply for DIN rail mounting, input: 2-phase, output: 24 V DC/90 W
About the category: AC/DC power supplies are power supplies that convert alternating current from the grid into direct current that is needed to power most electronics. AC/DC power supplies are integral components in systems that make the world go round.
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 2904371 Phoenix Contact price in the box on the right side or send a quick quote.
2904371 Product Details
- Depth 84 mm
- Degree of pollution 2
- Current consumption 0.55 A (400 V AC)
- Mains buffering time > 65 ms (400 V AC)
- Power factor (cos phi) 0.48
- Installation distance top/bottom 30 mm / 30 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Input voltage range 2x 264 V AC ... 575 V AC
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Nominal output voltage 24 V DC ±1 %
- Connection in series No
- Power loss nominal load max. < 12 W
- Protection class II (in closed control cabinet)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible max. 2.5 mm²
- Standard - Electrical safety IEC 62368-1/VDE 0805 (SELV)
- Width 55 mm
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Extended input voltage range in operation 2x 264 V AC ... 320 V AC (Derating 10 %)
- Nominal power consumption 211.3 VA
- Nominal output current (IN) 3.75 A
- Protection against overvoltage at the output (OVP) ≤ 35 V DC
- Net weight 0.32 kg
- Housing material Polycarbonate
- Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
- Conductor cross section AWG min. 24
- EMC requirements for noise immunity EN 61000-6-1
- Degree of protection IP20
- Climatic class 3K3 (in acc. with EN 60721)
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Input fuse 2 A (slow-blow, internal)
- Protective circuit/component Varistor
- Derating 55 °C ... 70 °C (2.5%/K)
- Output power 90 W
- Efficiency typ. 89 % (400 V AC)
- Insulation voltage input/output 4 kV AC (type test)
- Connection method Screw connection
- Conductor cross section AWG max. 14
- Screw thread M3
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Mains variation/undervoltage EN 61000-4-11
- Electrostatic discharge EN 61000-4-2
- Test field strength 10 V/m
- Input 2 kV (Test Level 3 - symmetrical)
- Voltage 10 V (Test Level 3)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 11.0 27040701
- Height 90 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Nominal input voltage range 2x 400 V AC ... 500 V AC
- Inrush current < 30 A (typical)
- Type of protection Transient surge protection
- Connection in parallel no
- Residual ripple < 50 mVPP (with nominal values)
- Maximum power dissipation in no-load condition < 0.7 W
- MTBF (IEC 61709, SN 29500) > 828000 h (40 °C)
- Conductor cross section solid max. 2.5 mm²
- Stripping length 8 mm
- EMC requirements for noise emission EN 61000-6-3
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- UL approvals UL/C-UL listed UL 508
- Discharge in air 8 kV (Test Level 3)
- Frequency range 10 kHz ... 80 MHz
- Output 1 kV (Test Level 2 - symmetrical)
- Voltage dips EN 61000-4-11
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Feedback voltage resistance < 35 V DC
- Foot latch material POM (Polyoxymethylen)
- Comments Criterion A
- ECLASS 5.0 27049000
- ECLASS 5.1 27049000
- UNSPSC 19.0 39121004
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Standard - Safety of transformers EN 61558-2-16
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field EN 61000-4-3
- Conducted interference EN 61000-4-6
- ECLASS 10.0.1 27040701
- ECLASS 6.0 27049000
- UNSPSC 13.2 39121004
- UNSPSC 21.0 39121004
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Standard - Safe isolation DIN VDE 0100-410
- Surge voltage load (surge) EN 61000-4-5
- ECLASS 7.0 27049002
- ECLASS 9.0 27040701
- ETIM 7.0 EC002540
- Contact discharge 6 kV (Test Level 3)
- Fast transients (burst) EN 61000-4-4
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 4.1 27040700
- ETIM 6.0 EC002540
- UNSPSC 20.0 39121004
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- ECLASS 4.0 27040700
- ETIM 4.0 EC002540
- UNSPSC 18.0 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨