2903154 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2903154 Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 3-phase, output: 24 V DC/10 A
Phoenix Contact

Part#:2903154

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 49

Apr 26, 2024

About the product: Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 3-phase, output: 24 V DC/10 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2903154 Phoenix Contact price in the box on the right side or send a quick quote.

2903154 Product Details

  • Depth
    160 mm
  • Degree of protection
    IP20
  • Nominal input voltage range
    3x 400 V AC ... 500 V AC
  • Discharge current to PE
    < 3.5 mA
  • Input fuse
    3.15 A (internal (device protection), slow-blow)
  • Protective circuit/component
    Varistor
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Power loss nominal load max.
    < 22 W (480 V AC)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Electrostatic discharge
    EN 61000-4-2
  • Frequency range
    0.15 MHz ... 80 MHz
  • Surge voltage load (surge)
    EN 61000-4-5
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 10.0.1
    27040701
  • ECLASS 6.0
    27049000
  • ETIM 4.0
    EC002540
  • UNSPSC 19.0
    39121004
  • Width
    42 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Ambient temperature (start-up type tested)
    -40 °C
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Nominal power consumption
    451.7 VA
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Maximum power dissipation in no-load condition
    < 1.1 W (400 V AC)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section solid max.
    1.5 mm²
  • Conductor cross section AWG min.
    24
  • Stripping length
    8 mm
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Electromagnetic HF field
    EN 61000-4-3
  • Contact discharge
    6 kV (Test Level 4)
  • Signal
    1 kV (Test Level 1 - symmetrical)
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 4.0
    27040700
  • ECLASS 9.0
    27040701
  • UNSPSC 18.0
    39121004
  • UNSPSC 21.0
    39121004
  • Installation distance top/bottom
    50 mm / 50 mm
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Input voltage range
    3x 400 V AC ... 500 V AC -20 % ....+15 %
  • Mains buffering time
    typ. 10 ms (400 V AC)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristics B, C, D, K)
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
  • Connection in series
    yes
  • Typical response time
    < 1 s
  • Efficiency
    > 92 % (at 400 V AC and nominal values)
  • Insulation voltage input/output
    3 kV AC (type test)
  • Conductor cross section flexible max.
    1.5 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Conducted noise emission
    EN 55016
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Input
    3 kV (Test Level 3 - symmetrical)
  • Voltage
    10 V (Test Level 3)
  • ECLASS 11.0
    27040701
  • ECLASS 5.1
    27049000
  • ETIM 6.0
    EC002540
  • UNSPSC 13.2
    39121004
  • UNSPSC 20.0
    39121004
  • Height
    130 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Degree of pollution
    2
  • AC frequency range
    50 Hz ... 60 Hz
  • Current consumption
    3x 0.6 A (400 V AC)
  • Power factor (cos phi)
    0.58
  • Type of protection
    Transient surge protection
  • Dynamic Boost (IDyn.Boost)
    15 A (5 s)
  • Nominal output current (IN)
    10 A
  • Output power
    240 W
  • Net weight
    0.9 kg
  • Protection class
    I (in closed control cabinet)
  • Assembly instructions
    alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
  • Standard - Safety of transformers
    EN 61558-2-16 (air clearances and creepage distances only)
  • Rail applications
    EN 50121-4
  • UL approvals
    UL Listed UL 508
  • Test field strength
    10 V/m (Test Level 3)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 5.0
    27049000
  • ECLASS 7.0
    27049002
  • ETIM 7.0
    EC002540
  • Installation distance right/left
    0 mm / 0 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Installation height
    ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
  • Inrush current
    ≤ 26 A (typical)
  • Nominal output voltage
    24 V DC ±1 %
  • Protection against overvoltage at the output (OVP)
    ≤ 30 V DC
  • Residual ripple
    ≤ 20 mVPP
  • MTBF (IEC 61709, SN 29500)
    > 2100000 h (25 °C)
  • Connection method
    Push-in connection
  • Conductor cross section AWG max.
    16
  • EMC requirements for noise emission
    EN 61000-6-3
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Discharge in air
    8 kV (Test Level 4)
  • Comments
    Criterion A
  • Fast transients (burst)
    EN 61000-4-4
  • Conducted interference
    EN 61000-4-6
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27040700

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 5 days!

1-year warranty

$252.46

2903154

Stock:

49

Select Qty:

$252.46

$252.46 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo