2902998 Phoenix Contact AC/DC Power Supplies
Part#:2902998
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Checking verified in-stock parts...
About the product: Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 12 V DC/30 W
About the category: AC/DC power supplies are power supplies that convert alternating current from the grid into direct current that is needed to power most electronics. AC/DC power supplies are integral components in systems that make the world go round.
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 2902998 Phoenix Contact price in the box on the right side or send a quick quote.
2902998 Product Details
- Depth 84 mm
- Stripping length 8 mm
- Mains variation/undervoltage EN 61000-4-11
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field EN 61000-4-3
- Input 2 kV (Test Level 3 - symmetrical)
- Voltage 10 V (Test Level 3)
- ECLASS 10.0.1 27040701
- ECLASS 4.1 27040700
- ETIM 6.0 EC002540
- ETIM 4.0 EC000599
- UNSPSC 20.0 39121004
- Width 22.5 mm
- Installation distance right/left 0 mm / 0 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Input voltage range 85 V AC ... 264 V AC
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Discharge in air 8 kV (Test Level 3)
- Comments Criterion A
- Voltage dips EN 61000-4-11
- ECLASS 4.0 27040700
- ECLASS 6.0 27049000
- Height 90 mm
- Degree of protection IP20
- Ambient temperature (start-up type tested) -25 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Current consumption 0.8 A (100 V AC)
- AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
- Mains buffering time > 20 ms (120 V AC)
- Input fuse 2 A (slow-blow, internal)
- Installation distance top/bottom 30 mm / 30 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Nominal input voltage range 100 V AC ... 240 V AC
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Nominal power consumption 71.7 VA
- Inrush current < 25 A (typical)
- Power factor (cos phi) 0.48
- Type of protection Transient surge protection
- Feedback voltage resistance < 25 V DC
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Protection against overvoltage at the output (OVP) ≤ 25 V DC
- MTBF (IEC 61709, SN 29500) > 953000 h (40 °C)
- Net weight 0.15 kg
- Protection class II (in closed control cabinet)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section AWG min. 24
- Screw thread M3
- Standard - Electrical safety IEC 62368-1/VDE 0805 (SELV)
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Electrostatic discharge EN 61000-4-2
- Test field strength 10 V/m
- Conducted interference EN 61000-4-6
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 5.0 27049000
- ECLASS 9.0 27040701
- UNSPSC 7.0901 39121004
- Housing material Polycarbonate
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section flexible max. 2.5 mm²
- Standard - Safety of transformers EN 61558-2-16
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Frequency range 10 kHz ... 80 MHz
- Fast transients (burst) EN 61000-4-4
- Surge voltage load (surge) EN 61000-4-5
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.1 27049000
- ECLASS 7.0 27049002
- UNSPSC 11 39121004
- UNSPSC 19.0 39121004
- Nominal output voltage 12 V DC ±1 %
- Nominal output current (IN) 2.5 A (-25 °C ... 55 °C)
- Residual ripple < 30 mVPP (with nominal values)
- Typical response time < 1 s
- Output power 30 W
- Insulation voltage input/output 4 kV AC (type test)
- Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG max. 14
- EMC requirements for noise emission EN 61000-6-3
- Standard - Safe isolation DIN VDE 0100-410
- UL approvals UL/C-UL listed UL 508
- Contact discharge 6 kV (Test Level 3)
- Output 1 kV (Test Level 2 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 11.0 27040701
- ETIM 3.0 EC001039
- UNSPSC 6.01 30211502
- UNSPSC 13.2 39121004
- UNSPSC 21.0 39121004
- ETIM 7.0 EC002540
- UNSPSC 18.0 39121004
- UNSPSC 12.01 39121004
- Connection in series yes
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Connection in parallel Yes, for redundancy and increased capacity
- Degree of pollution 2
- Protective circuit/component Varistor
- Power loss nominal load max. < 4.6 W
- Conductor cross section flexible min. 0.2 mm²
- Foot latch material POM (Polyoxymethylen)
- Derating 55 °C ... 70 °C (2.5%/K)
- Maximum power dissipation in no-load condition < 0.3 W
- Efficiency typ. 86 % (120 V AC)
- Connection method Screw connection
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨