2902993 Phoenix Contact AC/DC Power Supplies
Part#:2902993
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 1096
04/22/2024
About the product: Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/100 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902993 Phoenix Contact price in the box on the right side or send a quick quote.
2902993 Product Details
- Current consumption 2.1 A (100 V AC)
- ECLASS 11.0 27040701
- ECLASS 4.1 27040700
- ECLASS 5.1 27049000
- UNSPSC 13.2 39121004
- UNSPSC 11 39121004
- UNSPSC 21.0 39121004
- Installation distance right/left 0 mm / 0 mm
- Test field strength 10 V/m
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Input voltage range 85 V AC ... 264 V AC
- Power factor (cos phi) 0.47
- Derating 55 °C ... 70 °C (2.5%/K)
- Feedback voltage resistance < 35 V DC
- Output power 100 W
- Protection class II (in closed control cabinet)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Screw thread M3
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Surge voltage load (surge) EN 61000-4-5
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 9.0 27040701
- UNSPSC 7.0901 39121004
- Height 90 mm
- Installation distance top/bottom 30 mm / 30 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Nominal power consumption 242.6 VA
- Input fuse 4 A (slow-blow, internal)
- Nominal output voltage 24 V DC ±1 %
- Connection in parallel Yes, for redundancy and increased capacity
- Maximum power dissipation in no-load condition < 0.5 W
- Efficiency typ. 88 % (120 V AC)
- MTBF (IEC 61709, SN 29500) > 738000 h (40 °C)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG max. 14
- Standard - Safety of transformers EN 61558-2-16
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Mains variation/undervoltage EN 61000-4-11
- Electrostatic discharge EN 61000-4-2
- Fast transients (burst) EN 61000-4-4
- Input 2 kV (Test Level 3 - symmetrical)
- Voltage dips EN 61000-4-11
- ECLASS 10.0.1 27040701
- ETIM 4.0 EC000599
- UNSPSC 6.01 30211502
- Width 55 mm
- Degree of protection IP20
- Degree of pollution 2
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Type of protection Transient surge protection
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Power loss nominal load max. < 11 W
- Foot latch material POM (Polyoxymethylen)
- Connection method Screw connection
- Conductor cross section flexible max. 2.5 mm²
- Standard - Electrical safety IEC 62368-1/VDE 0805 (SELV)
- Standard - Safe isolation DIN VDE 0100-410
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Discharge in air 8 kV (Test Level 3)
- Comments Criterion A
- Voltage 10 V (Test Level 3)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.0 27049000
- ETIM 7.0 EC002540
- UNSPSC 19.0 39121004
- UNSPSC 20.0 39121004
- Depth 84 mm
- Ambient temperature (start-up type tested) -40 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Inrush current < 40 A (typical)
- Nominal output current (IN) 4.2 A (-25 °C ... 55 °C)
- Protection against overvoltage at the output (OVP) ≤ 35 V DC
- Typical response time < 1 s
- Insulation voltage input/output 4 kV AC (type test)
- Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
- Conductor cross section flexible min. 0.2 mm²
- EMC requirements for noise emission EN 61000-6-3
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Contact discharge 6 kV (Test Level 3)
- Output 1 kV (Test Level 2 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 4.0 27040700
- ECLASS 6.0 27049000
- ETIM 3.0 EC001039
- UNSPSC 12.01 39121004
- UNSPSC 18.0 39121004
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Nominal input voltage range 100 V AC ... 240 V AC
- Mains buffering time > 20 ms (120 V AC)
- Protective circuit/component Varistor
- Connection in series yes
- Residual ripple < 30 mVPP (with nominal values)
- Net weight 0.34 kg
- Housing material Polycarbonate
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG min. 24
- Stripping length 8 mm
- UL approvals UL/C-UL listed UL 508
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Frequency range 150 kHz ... 80 MHz
- Electromagnetic HF field EN 61000-4-3
- Conducted interference EN 61000-4-6
- ECLASS 7.0 27049002
- ETIM 6.0 EC002540
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
This item can ship within 24h!
1-year warranty
$101.75
2902993
Stock:
1096
Select Qty:
$101.75
$101.75 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products