2902832 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2902832 The configurable frequency transducer is suitable for the connection of NAMUR proximity sensors as well as for sensors with NPN and PNP outputs. Configurable via DIP switch and teach-in wheel. Screw connection, standard configuration.
Phoenix Contact

Part#:2902832

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: The configurable frequency transducer is suitable for the connection of NAMUR proximity sensors as well as for sensors with NPN and PNP outputs. Configurable via DIP switch and teach-in wheel. Screw connection, standard configuration.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2902832 Phoenix Contact price in the box on the right side or send a quick quote.

2902832 Product Details

  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Output name
    Voltage output / current output
  • Max. output current
    24.6 mA
  • Ripple
    < 20 mVPP
  • Typical current consumption
    < 28 mA (at IOUT = 20 mA, 24 V DC, load 500 Ω)
  • Conductor cross section AWG
    26 ... 12
  • Electrical isolation
    Basic insulation according to EN 61010
  • Test voltage, input/output/supply
    1.5 kV (50 Hz, 1 min.)
  • Housing material
    PBT
  • Standards/regulations
    EN 61000-4-6
  • Identification
    UL 508 Listed
  • Vibration
    B
  • REACh SVHC
    Lead 7439-92-1
  • ETIM 4.0
    EC002653
  • UNSPSC 11
    39121008
  • UNSPSC 13.2
    39121008
  • Width
    6.2 mm
  • Maximum altitude
    ≤ 2000 m
  • Degree of protection
    IP20
  • Available input sources
    NPN/PNP transistor outputs
  • Voltage output signal
    0 V ... 5 V
  • Load/output load current output
    500 Ω (at 20 mA)
  • Power consumption
    < 800 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω)
  • Stripping length
    12 mm
  • Transmission error in the set measuring range
    0.1 %
  • Protective circuit
    Transient protection
  • Rated insulation voltage
    50 V AC/DC
  • Noise emission
    EN 61000-6-4
  • Typical deviation from the measuring range final value
    0.3 %
  • ECLASS 10.0.1
    27210120
  • ECLASS 5.0
    27210100
  • ECLASS 9.0
    27210120
  • ETIM 6.0
    EC002653
  • UNSPSC 18.0
    39121008
  • UNSPSC 20.0
    39121008
  • Ambient temperature (operation)
    -20 °C ... 65 °C
  • Configurable/programmable
    Yes
  • Max. input amplitude
    30 V (incl. DC voltage)
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Screw thread
    M3
  • No. of channels
    1
  • Operating elements
    Press/slide button
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Mounting position
    any
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Certificate
    DNV GL TAA00002R0
  • ECLASS 11.0
    27210120
  • ECLASS 5.1
    27210100
  • ECLASS 6.0
    27210100
  • UNSPSC 7.0901
    39121008
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Depth
    101.2 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Frequency measuring range
    0.002 Hz ... 20 kHz (DIP switch)
  • Number of outputs
    1
  • Current output signal
    0 mA ... 20 mA
  • Load/output load voltage output
    ≥ 10 kΩ
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Status display
    LED red
  • Degree of pollution
    2
  • Color
    green
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Designation
    Shipbuilding approval
  • Humidity
    B
  • EMC
    A
  • ECLASS 4.1
    27210100
  • ECLASS 7.0
    27210120
  • ETIM 7.0
    EC002653
  • UNSPSC 12.01
    39121008
  • UNSPSC 19.0
    39121008
  • Height
    93.1 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Frequency input
    Frequency input
  • Max. output voltage
    approx. 12.3 V
  • Step response (0–99%)
    < 35 ms (At f > 500 Hz)
  • Connection method
    Screw connection
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Maximum temperature coefficient
    0.01 %/K
  • Overvoltage category
    II
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Temperature
    B
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27210100
  • UNSPSC 6.01
    30211506
  • UNSPSC 21.0
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo