2902048 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2902048
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Configurable temperature transducer with plug-in connection technology for connecting 2, 3, and 4-conductor resistance thermometers and resistance-type sensors. Configurable via DIP switch or software. Screw connection technology, order configuration
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902048 Phoenix Contact price in the box on the right side or send a quick quote.
2902048 Product Details
- Width 6.2 mm
- Height 109.81 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Linear resistance measuring range 0 Ω ... 4000 Ω (Minimum measuring span: 10% of the selected measuring range)
- Sensor input current approx. 200 µA
- Load/output load current output ≤ 600 Ω (at 20 mA)
- Stripping length 10 mm
- Transmission error resistance-type sensor 2 Ω
- Protective circuit Transient protection
- Noise emission EN 61000-6-4
- Designation Shipbuilding approval
- ATEX II 3 G Ex nA IIC T4 Gc X
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Number of outputs 1
- Max. output current 24.6 mA
- Ripple < 10 mVrms
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Transmission error resistance thermometer 0.1 % * 350 K / set measuring range; 0.1 % > 350 K (Pt/Ni)
- Electromagnetic compatibility Conformance with EMC directive
- Rated insulation voltage 300 V (effective)
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors
- Current output signal 0 mA ... 20 mA (via DIP switch)
- Load/output load voltage output ≥ 10 kΩ
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Screw thread M3
- Conductor cross section solid 0.2 mm² ... 1.5 mm² (with ferrule)
- Degree of pollution 2
- Housing material PBT
- ECLASS 5.1 27200200
- Configurable/programmable Yes
- Short-circuit current < 31.5 mA
- Power consumption ≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
- Torque 0.5 Nm ... 0.6 Nm
- Conductor cross section AWG 24 ... 12 (flexible)
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- UNSPSC 12.01 39121008
- Max. output voltage approx. 12.3 V
- Connection method Screw connection
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
- UL, USA/Canada UL 508 Listed
- ECLASS 9.0 27210129
- ETIM 7.0 EC002919
- UNSPSC 11 39121008
- UNSPSC 19.0 41112105
- Typical current consumption 32 mA (24 V DC)
- Mounting position any
- Identification C, EMC2
- ECLASS 10.0.1 27210129
- ECLASS 6.0 27200200
- ETIM 3.0 EC001446
- UNSPSC 7.0901 39121008
- UNSPSC 20.0 41112105
- Depth 119.2 mm
- Degree of protection IP20 (not assessed by UL)
- Connection technology 2-, 3-, 4-conductor
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- Standards/regulations EN 61000-4-6
- Conformance CE-compliant
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 11.0 27210129
- ETIM 2.0 EC001446
- UNSPSC 13.2 41112105
- Ambient temperature (operation) -40 °C ... 70 °C
- Typical deviation from the measuring range final value 0.07 %
- Temperature measuring range -200 °C ... 850 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 850°C via DIP switches)
- Maximum temperature coefficient 0.01 %/K
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- Certificate DNV GL 14445-15HH
- ECLASS 4.0 27200200
- ECLASS 4.1 27200200
- ETIM 6.0 EC002919
- ETIM 4.0 EC001446
- UNSPSC 21.0 41112105
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Voltage output signal 0 V ... 5 V (via DIP switch)
- Overvoltage category II
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27200200
- ECLASS 7.0 27200206
- UNSPSC 6.01 30211506
- UNSPSC 18.0 41112105
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2902048
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨