2902036 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2902036 3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. Screw connection technology, order configu
Phoenix Contact

Part#:2902036

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: 3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. Screw connection technology, order configu

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2902036 Phoenix Contact price in the box on the right side or send a quick quote.

2902036 Product Details

  • Number of inputs
    1
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Voltage input signal
    0 V ... 5 V (via DIP switch)
  • Max. output current
    22 mA
  • Nominal supply voltage
    24 V DC
  • Connection method
    Screw connection
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • Temperature coefficient, typical
    0.01 %/K
  • Degree of pollution
    2
  • Current output signal
    0 mA ... 20 mA (via DIP switch)
  • Load/output load voltage output
    ≥ 10 kΩ
  • Stripping length
    10 mm
  • Conductor cross section AWG
    24 ... 12 (flexible)
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Load/output load current output
    ≤ 600 Ω (at 20 mA)
  • Power consumption
    ≤ 800 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
  • Torque
    0.5 Nm ... 0.6 Nm
  • Limit frequency (3 dB)
    30 Hz (via DIP switch)
  • Test voltage, input/output/supply
    3 kV (50 Hz, 1 min.)
  • Color
    gray
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Standards/regulations
    EN 61000-4-6
  • Temperature
    B
  • ECLASS 10.0.1
    27210120
  • ECLASS 6.0
    27210100
  • Humidity
    B
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.0
    27210100
  • ETIM 4.0
    EC002653
  • UNSPSC 13.2
    39121008
  • Ripple
    < 20 mVPP (at 600 Ω)
  • Screw thread
    M3
  • No. of channels
    1
  • Step response (10-90%)
    < 8.5 ms (with 30 Hz filter)
  • Rated insulation voltage
    300 V (effective)
  • Noise emission
    EN 61000-6-4
  • Designation
    Shipbuilding approval
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm² (with ferrule)
  • Maximum transmission error
    ≤ 0.1 % (of final value)
  • Maximum temperature coefficient
    0.01 %/K
  • Protective circuit
    Transient protection
  • Housing material
    PBT
  • Certificate
    DNV GL TAA00002UA
  • EMC
    A
  • ECLASS 4.1
    27210100
  • ECLASS 5.1
    27210100
  • ETIM 7.0
    EC002653
  • UNSPSC 20.0
    39121008
  • Height
    109.81 mm
  • Width
    6.2 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • max. input voltage
    33 V
  • Number of outputs
    1
  • Typical current consumption
    25 mA (Current output, at 24 V DC incl. load)
  • Input resistance current input
    approx. 63 Ω (+0.7 V for test diode)
  • Short-circuit current
    < 32 mA
  • UNSPSC 19.0
    39121008
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Max. input current
    24 mA
  • UNSPSC 21.0
    39121008
  • Current input signal
    0 mA ... 20 mA (via DIP switch)
  • Input resistance of voltage input
    > 1000 kΩ
  • Depth
    119.2 mm
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • Voltage output signal
    0 V ... 5 V (via DIP switch)
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Degree of protection
    IP20 (not assessed by UL)
  • Configurable/programmable
    Yes
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • ETIM 6.0
    EC002653
  • Mounting position
    any
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27210100
  • ECLASS 11.0
    27210120
  • ECLASS 9.0
    27210120
  • Vibration
    A
  • Identification
    UL 508 Listed
  • UNSPSC 18.0
    39121008
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Overvoltage category
    II
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 7.0
    27210120

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo