Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2902000 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2902000 3-way signal conditioner with plug-in connection technology for the electrical isolation of analog signals. Input signal: 0 ... 20 mA, output signal: 0 ... 10 V, screw connection technology
Phoenix Contact

Part#:2902000

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: 3-way signal conditioner with plug-in connection technology for the electrical isolation of analog signals. Input signal: 0 ... 20 mA, output signal: 0 ... 10 V, screw connection technology

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2902000 Phoenix Contact price in the box on the right side or send a quick quote.

2902000 Product Details

  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Number of inputs
    1
  • Number of outputs
    1
  • Nominal supply voltage
    24 V DC
  • Typical current consumption
    25 mA (24 V DC)
  • Maximum temperature coefficient
    0.01 %/K
  • Maximum transmission error
    0.1 % (of final value)
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Maximum altitude
    ≤ 2000 m
  • Configurable/programmable
    no
  • Load/output load voltage output
    ≥ 10 kΩ
  • Power consumption
    ≤ 200 mW (at 9.6 V DC)
  • Screw thread
    M3
  • Conductor cross section AWG
    24 ... 12 (flexible)
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Overvoltage category
    II
  • Color
    gray
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Humidity
    B
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 4.1
    27210100
  • ECLASS 5.0
    27210100
  • UNSPSC 12.01
    39121004
  • Width
    6.2 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Current input signal
    0 mA ... 20 mA
  • Ripple
    < 20 mVPP (at 10 kΩ)
  • Stripping length
    10 mm
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • Temperature coefficient, typical
    0.01 %/K
  • Degree of pollution
    2
  • Test voltage, input/output/supply
    3 kV (50 Hz, 1 min.)
  • Housing material
    PBT
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Certificate
    DNV GL TAA00002UA
  • Vibration
    A
  • ECLASS 11.0
    27210120
  • ETIM 4.0
    EC002653
  • ETIM 6.0
    EC002653
  • UNSPSC 13.2
    39121008
  • UNSPSC 21.0
    39121008
  • Depth
    119.2 mm
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Voltage output signal
    0 V ... 10 V
  • Short-circuit current
    < 15 mA
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm² (with ferrule)
  • Torque
    0.5 Nm ... 0.6 Nm
  • Limit frequency (3 dB)
    approx. 30 Hz
  • Rated insulation voltage
    300 V (effective)
  • Mounting position
    any
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Standards/regulations
    EN 61000-4-6
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 6.0
    27210100
  • ECLASS 7.0
    27210120
  • UNSPSC 7.0901
    39121004
  • UNSPSC 18.0
    39121008
  • Height
    109.81 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of protection
    IP20 (not assessed by UL)
  • Input resistance current input
    approx. 63 Ω (+0.7 V for test diode)
  • Max. output voltage
    11 V
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Connection method
    Screw connection
  • No. of channels
    1
  • Step response (10-90%)
    approx. 10 ms
  • Protective circuit
    Transient protection
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • Designation
    Shipbuilding approval
  • Temperature
    B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27210100
  • ECLASS 9.0
    27210120
  • UNSPSC 11
    39121004
  • UNSPSC 19.0
    39121008
  • Noise emission
    EN 61000-6-4
  • Identification
    UL 508 Listed
  • EMC
    A
  • ECLASS 10.0.1
    27210120
  • ECLASS 5.1
    27210100
  • UNSPSC 6.01
    30211502
  • ETIM 7.0
    EC002653
  • UNSPSC 20.0
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2902000

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo